Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 108HC-415 M10 NTYP SL — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 108HC-415 M10 NTYP SL is a 415.0 W STC (391.7 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 38.02 V Voc at 25 C, and 41.2 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
415.0 W
PTC Wattage
391.7 W
Voc @ 25C
38.02 V
Efficiency
21.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 108HC-415 M10 NTYP SL Compare Against Peer CEC Listings?

How Heliene Heliene 108HC-415 M10 NTYP SL handles rooftop heat (391.7 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 108HC-415 M10 NTYP SL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). Compared against AXITEC AC-415TGB/108BB (415.0 W), this model holds strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Lower 38.02 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.7 A overcurrent floor served by a 25 A breaker.

Where Does Heliene 108HC-415 M10 NTYP SL Fall Across Listed CEC Models?

Where Heliene 108HC-415 M10 NTYP SL (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 108HC-415 M10 NTYP SL (415.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 108HC-415 : 415.0 W

What Dataset Percentiles Define Heliene 108HC-415 M10 NTYP SL?

Percentile placement of Heliene 108HC-415 M10 NTYP SL across power density (212.8 W/m2), thermal retention, and nameplate STC wattage.

Heliene 108HC-415 M10 NTYP SL Engineering BenchmarksPercentile comparison of Heliene 108HC-415 M10 NTYP SL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage415.0 WPTC/STC Retention94.4%Module Efficiency21.28%

What Do the Dataset Ranks Show for Heliene 108HC-415 M10 NTYP SL?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 108HC-415 M10 NTYP SL specifications.

Rank #8,199 / 21,677

Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,257

21.28% Aperture Efficiency

Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.2 V at -10 C (576.8 V string) and 42.11 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,300 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 21.7 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.02 * (1 + (-0.239/100) * (-10 - 25)) = 41.2 V | OCPD = 1.56 * 13.91 = 21.7 A

Inputs from CEC Modules.csv for Heliene 108HC-415 M10 NTYP SL: Voc=38.02 V, beta_Voc=-0.239%/C, Isc=13.91 A, STC=415.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (576.8 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Heliene 108HC-415 M10 NTYP SL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 108HC-415 M10 NTYP SL.

Official California Energy Commission (NREL SAM) test parameters for Heliene 108HC-415 M10 NTYP SL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 415.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 391.7 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.02 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.65 V / 13.13 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.239 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.28% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 108HC-415 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 108HC-415 M10 NTYP SL (415.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.22 kW 315 sq ft $1,557 $2,632
8 kW Class 20 8.3 kW 420 sq ft $2,077 $3,513
10 kW Class 25 10.38 kW 525 sq ft $2,598 $4,393

How Many Heliene 108HC-415 M10 NTYP SL Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 108HC-415 M10 NTYP SL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.02V and beta_Voc=-0.239%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.11 V 14 panels 589.5 V 23 panels
-10 C (14 F) 41.2 V 14 panels 576.8 V 24 panels
0 C (32 F) 40.29 V 14 panels 564.1 V 24 panels
25 C (77 F STC) 38.02 V 15 panels 570.3 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 108HC-415 M10 NTYP SL?

Alternative CEC solar modules from competing brands near Heliene 108HC-415 M10 NTYP SL (415.0 W), including AXITEC AC-415TGB/108BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-415TGB/108BB
AXITEC
415.0 W Tie (0 W) 38.04 V 21.84% 94.9%
Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a
Aptos Solar Technology LLC
415.0 W Tie (0 W) 37.7 V 21.39% 93.0%
Boviet Solar Technology Co Ltd BVM7609M-415-H-HC
Boviet Solar Technology Co Ltd
415.0 W Tie (0 W) 38.47 V 19.21% 94.7%
Aptos Solar Technology LLC DNA-108-BF10-415W
Aptos Solar Technology LLC
415.0 W Tie (0 W) 37.5 V 21.28% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 108HC-415 M10 NTYP SL?

Evaluate Heliene 108HC-415 M10 NTYP SL (415.0 W STC, 38.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 108HC-415 M10 NTYP SL reaches 42.11 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 108HC-415 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 108HC-415 M10 NTYP SL 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-415TGB/108BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 108HC-415 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Heliene 108HC-415 M10 NTYP SL?

Multiplying Heliene 108HC-415 M10 NTYP SL's 13.91 A short-circuit current by 1.56 equals 21.7 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Heliene 108HC-415 M10 NTYP SL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.2 V cold Voc at 14 F and handles 13.91 A Isc; string inverters cap Heliene 108HC-415 M10 NTYP SL at 14 panels on 600 V.

Is Heliene 108HC-415 M10 NTYP SL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 108HC-415 M10 NTYP SL rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.