AXITEC AC-415TGB/108BB is a 415.0 W STC (394.0 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.84% efficiency, 38.04 V Voc at 25 C, and 41.38 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 394.0 W
- Voc @ 25C
- 38.04 V
- Efficiency
- 21.84%
How Does AXITEC AC-415TGB/108BB Compare Against Peer CEC Listings?
How AXITEC AXITEC AC-415TGB/108BB handles rooftop heat (394.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, AXITEC AC-415TGB/108BB exhibits 13.96 A short-circuit current, requiring a 21.78 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,199 of 21,677 (5.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.0 m2 for an 8 kW system (25 panels for 10 kW). Lower 38.04 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does AXITEC AC-415TGB/108BB Fall Across Listed CEC Models?
Where AXITEC AC-415TGB/108BB (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-415TGB/108BB?
Percentile placement of AXITEC AC-415TGB/108BB across power density (218.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for AXITEC AC-415TGB/108BB?
Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-415TGB/108BB specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.84% Aperture Efficiency
Power density 218.4 W/m2 (1.93 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.38 V at -10 C (579.3 V string) and 42.34 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,880 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.04 * (1 + (-0.251/100) * (-10 - 25)) = 41.38 V | OCPD = 1.56 * 13.96 = 21.78 A
Inputs from CEC Modules.csv for AXITEC AC-415TGB/108BB: Voc=38.04 V, beta_Voc=-0.251%/C, Isc=13.96 A, STC=415.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (579.3 V); 20 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for AXITEC AC-415TGB/108BB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-415TGB/108BB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 394.0 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.37 V / 13.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.84% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-415TGB/108BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-415TGB/108BB (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 307 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 409 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 511 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-415TGB/108BB architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-410TGB/108BB | 410.0 W | 389.1 W | 37.94 V | 31.25 V | 21.58% |
| AXITEC AC-415TGB/108BB | 415.0 W | 394.0 W | 38.04 V | 31.37 V | 21.84% |
| AXITEC AC-420TGB/108BB | 420.0 W | 398.9 W | 38.13 V | 31.49 V | 22.11% |
How Many AXITEC AC-415TGB/108BB Modules Fit in a Cold-Weather String?
Maximum series module counts for AXITEC AC-415TGB/108BB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.34 V | 14 panels | 592.8 V | 23 panels |
| -10 C (14 F) | 41.38 V | 14 panels | 579.3 V | 24 panels |
| 0 C (32 F) | 40.43 V | 14 panels | 566.0 V | 24 panels |
| 25 C (77 F STC) | 38.04 V | 15 panels | 570.6 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-415TGB/108BB?
Alternative CEC solar modules from competing brands near AXITEC AC-415TGB/108BB (415.0 W), including Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC Boviet Solar Technology Co Ltd |
415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
| Auxin Solar AXN10M420W Auxin Solar |
420.0 W | +5.0 W | 38.26 V | 21.65% | 93.2% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-415TGB/108BB?
Evaluate AXITEC AC-415TGB/108BB (415.0 W STC, 38.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-415TGB/108BB reaches 42.34 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-415TGB/108BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-415TGB/108BB 8 kW Residential Fit
Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 394.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-415TGB/108BB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AXITEC AC-415TGB/108BB PTC wattage (394.0 W) lower than STC (415.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 394.0 W PTC (94.9% retention) across AXITEC AC-415TGB/108BB's 1.9 m2 aperture.
Who should skip AXITEC AC-415TGB/108BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 AXITEC AC-415TGB/108BB panels (409 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
What is the 1,000 V commercial string limit for AXITEC AC-415TGB/108BB?
On 1,000 V commercial inverters at -10 C (41.38 V cold Voc), AXITEC AC-415TGB/108BB fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-415TGB/108BB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)