Skip to main content
WireAndSun
Calculators
CEC PV Module

Aptos Solar Technology LLC DNA-108-BF10-415W — CEC Solar Module Specifications

Manufacturer: Aptos Solar Technology LLC Registry: CEC Verified Engineering Specification

Aptos Solar Technology LLC DNA-108-BF10-415W is a 415.0 W STC (391.2 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 37.5 V Voc at 25 C, and 41.25 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
415.0 W
PTC Wattage
391.2 W
Voc @ 25C
37.5 V
Efficiency
21.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Aptos Solar Technology LLC DNA-108-BF10-415W Compare Against Peer CEC Listings?

Engineering position of Aptos Solar Technology LLC DNA-108-BF10-415W (415.0 W STC) vs. AXITEC AC-415MH/108V across 5,889 CEC Mono-c-Si solar modules.

Ranking #8,199 across 21,677 CEC solar panels (top 39.4%; higher than 60.6% of peers), Aptos Solar Technology LLC DNA-108-BF10-415W operates as a modern high-density residential and light-commercial module sitting 5.0 W above the 410.0 W Mono-c-Si median. Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), 20 panels occupy 420 sq ft and offset roughly $2,077/yr at average US rates (or $3,513/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Aptos Solar Technology LLC DNA-108-BF10-415W Fall Across Listed CEC Models?

Plots Aptos Solar Technology LLC DNA-108-BF10-415W at 415.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Aptos Solar Technology LLC DNA-108-BF10-415W (415.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAptos Solar Techno: 415.0 W

What Dataset Percentiles Define Aptos Solar Technology LLC DNA-108-BF10-415W?

Benchmarks Aptos Solar Technology LLC DNA-108-BF10-415W on STC wattage, thermal PTC/STC retention, and 21.28 aperture conversion efficiency against CEC peers.

Aptos Solar Technology LLC DNA-108-BF10-415W Engineering BenchmarksPercentile comparison of Aptos Solar Technology LLC DNA-108-BF10-415W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage415.0 WPTC/STC Retention94.3%Module Efficiency21.28%

What Do the Dataset Ranks Show for Aptos Solar Technology LLC DNA-108-BF10-415W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Aptos Solar Technology LLC DNA-108-BF10-415W by Aptos Solar Technology LLC.

Rank #8,199 / 21,677

Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,257

21.28% Aperture Efficiency

Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.25 V at -10 C (577.5 V string) and 42.33 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,300 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,824 W PTC; NEC 690.8 OCPD floor is 21.87 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.286/100) * (-10 - 25)) = 41.25 V | OCPD = 1.56 * 14.02 = 21.87 A

Inputs from CEC Modules.csv for Aptos Solar Technology LLC DNA-108-BF10-415W: Voc=37.5 V, beta_Voc=-0.286%/C, Isc=14.02 A, STC=415.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (577.5 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Aptos Solar Technology LLC DNA-108-BF10-415W?

Laboratory test ratings recorded for Aptos Solar Technology LLC DNA-108-BF10-415W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Aptos Solar Technology LLC DNA-108-BF10-415W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 415.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 391.2 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.6 V / 13.13 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.286 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.28% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Aptos Solar Technology LLC DNA-108-BF10-415W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for Aptos Solar Technology LLC DNA-108-BF10-415W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.22 kW 315 sq ft $1,557 $2,632
8 kW Class 20 8.3 kW 420 sq ft $2,077 $3,513
10 kW Class 25 10.38 kW 525 sq ft $2,598 $4,393

How Many Aptos Solar Technology LLC DNA-108-BF10-415W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Aptos Solar Technology LLC DNA-108-BF10-415W (beta_Voc -0.286%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.5V and beta_Voc=-0.286%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.33 V 14 panels 592.6 V 23 panels
-10 C (14 F) 41.25 V 14 panels 577.5 V 24 panels
0 C (32 F) 40.18 V 14 panels 562.5 V 24 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Aptos Solar Technology LLC DNA-108-BF10-415W?

Closest cross-brand CEC competitors to Aptos Solar Technology LLC DNA-108-BF10-415W matched near 415.0 W STC and 37.5 V Voc, led by AXITEC AC-415MH/108V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-415MH/108V
AXITEC
415.0 W Tie (0 W) 37.38 V 21.5% 92.7%
AXITEC AC-415TGB/108BB
AXITEC
415.0 W Tie (0 W) 38.04 V 21.84% 94.9%
Boviet Solar Technology Co Ltd BVM7609M-415-H-HC
Boviet Solar Technology Co Ltd
415.0 W Tie (0 W) 38.47 V 19.21% 94.7%
Bluesun Solar CoLtd BSM410M10-54HPH
Bluesun Solar CoLtd
410.0 W -5.0 W 37.5 V 20.99% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Aptos Solar Technology LLC DNA-108-BF10-415W?

Evaluate Aptos Solar Technology LLC DNA-108-BF10-415W (415.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Aptos Solar Technology LLC DNA-108-BF10-415W reaches 42.33 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Aptos Solar Technology LLC DNA-108-BF10-415W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Aptos Solar Technology LLC DNA-108-BF10-415W 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-415MH/108V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Aptos Solar Technology LLC DNA-108-BF10-415W by Aptos Solar Technology LLC grounded in CEC test data and NEC 690.7/690.8 limits.

How many Aptos Solar Technology LLC DNA-108-BF10-415W panels fit on a 600 V winter solar string?

At -10 C (14 F), Aptos Solar Technology LLC DNA-108-BF10-415W cold Voc rises from 37.5 V to 41.25 V (beta_Voc -0.286%/C), capping a 600 V string at 14 panels (577.5 V).

How much roof area does an 8 kW array of Aptos Solar Technology LLC DNA-108-BF10-415W need?

An 8 kW DC system uses 20 Aptos Solar Technology LLC DNA-108-BF10-415W modules (8,300 W STC / 7,824 W PTC), covering roughly 420 sq ft and saving ~$2,077/yr at 18.54 c/kWh.

How does Aptos Solar Technology LLC DNA-108-BF10-415W compare against AXITEC AC-415MH/108V?

Aptos Solar Technology LLC DNA-108-BF10-415W outputs 415.0 W STC (37.5 V Voc, rank #8,199 of 21,677), while AXITEC AC-415MH/108V delivers 415.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.