Manufacturer: Aptos Solar Technology LLC Registry: CEC Verified Engineering Specification

Aptos Solar Technology LLC DNA-144-BFN10-605W-DG is a 605.0 W STC (575.1 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 23.45% efficiency, 52.9 V Voc at 25 C, and 56.94 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
605.0 W
PTC Wattage
575.1 W
Voc @ 25C
52.9 V
Efficiency
23.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Aptos Solar Technology LLC DNA-144-BFN10-605W-DG Compare Against Peer CEC Listings?

Solar engineering breakdown for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Aptos Solar Technology LLC and peers, Aptos Solar Technology LLC DNA-144-BFN10-605W-DG stands 195.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,514-$2,575/yr in baseline US bill offset. Higher 52.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Aptos Solar Technology LLC DNA-144-BFN10-605W-DG Fall Across Listed CEC Models?

Distribution marker showing Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (605.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (605.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAptos Solar Techno: 605.0 W

What Dataset Percentiles Define Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Dataset percentiles tracking Aptos Solar Technology LLC DNA-144-BFN10-605W-DG power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Aptos Solar Technology LLC DNA-144-BFN10-605W-DG Engineering BenchmarksPercentile comparison of Aptos Solar Technology LLC DNA-144-BFN10-605W-DG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage605.0 WPTC/STC Retention95.1%Module Efficiency23.45%

What Do the Dataset Ranks Show for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Benchmark highlights for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,214 / 21,677

Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #560

23.45% Aperture Efficiency

Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.94 V at -10 C (569.4 V string) and 58.09 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,470 W STC

Occupies 36.1 m2 (389 sq ft) producing 8,051 W PTC; NEC 690.8 OCPD floor is 21.92 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.9 * (1 + (-0.218/100) * (-10 - 25)) = 56.94 V | OCPD = 1.56 * 14.05 = 21.92 A

Inputs from CEC Modules.csv for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG: Voc=52.9 V, beta_Voc=-0.218%/C, Isc=14.05 A, STC=605.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (569.4 V); 14 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Official CEC datasheet figures for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 605.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 575.1 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.9 V / 13.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.218 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.45% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Aptos Solar Technology LLC DNA-144-BFN10-605W-DG Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Aptos Solar Technology LLC DNA-144-BFN10-605W-DG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.05 kW 278 sq ft $1,514 $2,561
8 kW Class 14 8.47 kW 389 sq ft $2,120 $3,585
10 kW Class 17 10.29 kW 472 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Aptos Solar Technology LLC Series?

Consolidated Aptos Solar Technology LLC wattage variants sharing the Aptos Solar Technology LLC DNA-144-BFN10-605W-DG mechanical and cell layout.

Sibling CEC listings grouped into the Aptos Solar Technology LLC DNA-144-BFN10-605W-DG wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Aptos Solar Technology LLC DNA-144-BFN10-600W-DG 600.0 W 570.2 W 52.7 V 44.8 V 23.26%
Aptos Solar Technology LLC DNA-144-BFN10-605W-DG 605.0 W 575.1 W 52.9 V 44.9 V 23.45%
Aptos Solar Technology LLC DNA-144-BFN10-610W-DG 610.0 W 579.9 W 53.1 V 45.1 V 23.64%

How Many Aptos Solar Technology LLC DNA-144-BFN10-605W-DG Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (56.94 V at 14 F).

Computed from Voc=52.9V and beta_Voc=-0.218%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.09 V 10 panels 580.9 V 17 panels
-10 C (14 F) 56.94 V 10 panels 569.4 V 17 panels
0 C (32 F) 55.78 V 10 panels 557.8 V 17 panels
25 C (77 F STC) 52.9 V 11 panels 581.9 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Competing CEC solar panels closest to Aptos Solar Technology LLC DNA-144-BFN10-605W-DG in nameplate wattage and Voc, starting with BLUESUN GROUP LIMITED BSM605M10-72HNH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BLUESUN GROUP LIMITED BSM605M10-72HNH
BLUESUN GROUP LIMITED
605.0 W Tie (0 W) 52.9 V 23.45% 95.1%
JA Solar JAM78D30-605/MB
JA Solar
605.0 W Tie (0 W) 53.61 V 22.24% 93.8%
LONGi Green Energy Technology Co Ltd LR5-78HBD-605M
LONGi Green Energy Technology Co Ltd
605.0 W Tie (0 W) 54.2 V 22.24% 94.5%
CSI Solar Co Ltd CS6W-600TB-AG
CSI Solar Co Ltd
600.0 W -5.0 W 53.0 V 23.9% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Evaluate Aptos Solar Technology LLC DNA-144-BFN10-605W-DG (605.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Aptos Solar Technology LLC DNA-144-BFN10-605W-DG reaches 58.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Aptos Solar Technology LLC DNA-144-BFN10-605W-DG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Aptos Solar Technology LLC DNA-144-BFN10-605W-DG 8 kW Residential Fit

Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare BLUESUN GROUP LIMITED BSM605M10-72HNH.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 575.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG by Aptos Solar Technology LLC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Aptos Solar Technology LLC DNA-144-BFN10-605W-DG?

Multiplying Aptos Solar Technology LLC DNA-144-BFN10-605W-DG's 14.05 A short-circuit current by 1.56 equals 21.92 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Aptos Solar Technology LLC DNA-144-BFN10-605W-DG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.94 V cold Voc at 14 F and handles 14.05 A Isc; string inverters cap Aptos Solar Technology LLC DNA-144-BFN10-605W-DG at 10 panels on 600 V.

Is Aptos Solar Technology LLC DNA-144-BFN10-605W-DG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Aptos Solar Technology LLC DNA-144-BFN10-605W-DG rely on utility bill offset (~$2,120/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.