AXITEC AC-415MH/108V is a 415.0 W STC (384.8 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.5% efficiency, 37.38 V Voc at 25 C, and 40.85 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 384.8 W
- Voc @ 25C
- 37.38 V
- Efficiency
- 21.5%
How Does AXITEC AC-415MH/108V Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-415MH/108V: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Across 5,889 Mono-c-Si listings from AXITEC and peers, AXITEC AC-415MH/108V stands 5.0 W above the 410.0 W Mono-c-Si median and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,557-$2,598/yr in baseline US bill offset. Lower 37.38 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does AXITEC AC-415MH/108V Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-415MH/108V (415.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define AXITEC AC-415MH/108V?
Dataset percentiles tracking AXITEC AC-415MH/108V power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for AXITEC AC-415MH/108V?
Benchmark highlights for AXITEC AC-415MH/108V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.5% Aperture Efficiency
Power density 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.85 V at -10 C (571.9 V string) and 41.84 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.87 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.38 * (1 + (-0.265/100) * (-10 - 25)) = 40.85 V | OCPD = 1.56 * 14.02 = 21.87 A
Inputs from CEC Modules.csv for AXITEC AC-415MH/108V: Voc=37.38 V, beta_Voc=-0.265%/C, Isc=14.02 A, STC=415.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (571.9 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for AXITEC AC-415MH/108V?
Official CEC datasheet figures for AXITEC AC-415MH/108V (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 384.8 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.38 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.19 V / 13.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.5% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-415MH/108V Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-415MH/108V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 312 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 415 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 519 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Consolidated AXITEC wattage variants sharing the AXITEC AC-415MH/108V mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-410MH/108V | 410.0 W | 380.0 W | 37.23 V | 31.03 V | 21.24% |
| AXITEC AC-415MH/108V | 415.0 W | 384.8 W | 37.38 V | 31.19 V | 21.5% |
How Many AXITEC AC-415MH/108V Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-415MH/108V (40.85 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.84 V | 14 panels | 585.8 V | 23 panels |
| -10 C (14 F) | 40.85 V | 14 panels | 571.9 V | 24 panels |
| 0 C (32 F) | 39.86 V | 15 panels | 597.9 V | 25 panels |
| 25 C (77 F STC) | 37.38 V | 16 panels | 598.1 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-415MH/108V?
Competing CEC solar panels closest to AXITEC AC-415MH/108V in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-BF10-415W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC Boviet Solar Technology Co Ltd |
415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | -5.0 W | 37.34 V | 21.24% | 92.2% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-415MH/108V?
Evaluate AXITEC AC-415MH/108V (415.0 W STC, 37.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-415MH/108V reaches 41.84 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-415MH/108V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-415MH/108V 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BF10-415W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-415MH/108V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-415MH/108V?
Multiplying AXITEC AC-415MH/108V's 14.02 A short-circuit current by 1.56 equals 21.87 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can AXITEC AC-415MH/108V pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.85 V cold Voc at 14 F and handles 14.02 A Isc; string inverters cap AXITEC AC-415MH/108V at 14 panels on 600 V.
Is AXITEC AC-415MH/108V eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-415MH/108V rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)