Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN10M420W — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M420W is a 420.0 W STC (391.5 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.65% efficiency, 38.26 V Voc at 25 C, and 41.82 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
391.5 W
Voc @ 25C
38.26 V
Efficiency
21.65%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M420W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Auxin Solar AXN10M420W (Mono-c-Si) residential solar systems.

Homeowners evaluating Auxin Solar AXN10M420W need 15 panels for 6 kW or 20 panels (418 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 41.82 V at 14 F and 42.84 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN10M420W Fall Across Listed CEC Models?

Comparison of Auxin Solar AXN10M420W (420.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M420W (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 420.0 W

What Dataset Percentiles Define Auxin Solar AXN10M420W?

Relative ranking of Auxin Solar AXN10M420W across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Auxin Solar AXN10M420W Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M420W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention93.2%Module Efficiency21.65%

What Do the Dataset Ranks Show for Auxin Solar AXN10M420W?

Summary of Auxin Solar AXN10M420W output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,009

21.65% Aperture Efficiency

Power density 216.5 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.82 V at -10 C (585.5 V string) and 42.84 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,830 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.26 * (1 + (-0.266/100) * (-10 - 25)) = 41.82 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M420W: Voc=38.26 V, beta_Voc=-0.266%/C, Isc=13.71 A, STC=420.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (585.5 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M420W?

Complete CEC test sheet for Auxin Solar AXN10M420W including Isc (13.71 A), Voc (38.26 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M420W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 391.5 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.62 V / 12.89 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.65% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M420W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Auxin Solar AXN10M420W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 313 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 418 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 501 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Related Auxin Solar power steps and black/silver trims consolidated into this Auxin Solar AXN10M420W series guide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Auxin Solar AXN10M420W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M415W 415.0 W 386.7 W 38.04 V 32.18 V 21.39%
Auxin Solar AXN10M420W 420.0 W 391.5 W 38.26 V 32.62 V 21.65%

How Many Auxin Solar AXN10M420W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Auxin Solar AXN10M420W (38.26 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.26V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.84 V 14 panels 599.8 V 23 panels
-10 C (14 F) 41.82 V 14 panels 585.5 V 23 panels
0 C (32 F) 40.8 V 14 panels 571.2 V 24 panels
25 C (77 F STC) 38.26 V 15 panels 573.9 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M420W?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-108-MFN10-420W (420.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MFN10-420W
Aptos Solar Technology LLC
420.0 W Tie (0 W) 38.5 V 21.65% 95.0%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420
Elin Energy (Sirius PV)
420.0 W Tie (0 W) 38.5 V 21.65% 94.9%
Elin Energy (Sirius PV) ELNSM54M-HC-N-420
Elin Energy (Sirius PV)
420.0 W Tie (0 W) 38.5 V 21.65% 94.9%
AE Solar GmbH AE420CMD-108BDE
AE Solar GmbH
420.0 W Tie (0 W) 39.7 V 21.54% 94.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M420W?

Evaluate Auxin Solar AXN10M420W (420.0 W STC, 38.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M420W reaches 42.84 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M420W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M420W 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MFN10-420W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M420W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Auxin Solar AXN10M420W PTC wattage (391.5 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 391.5 W PTC (93.2% retention) across Auxin Solar AXN10M420W's 1.94 m2 aperture.

Who should skip Auxin Solar AXN10M420W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Auxin Solar AXN10M420W panels (418 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-MFN10-420W.

What is the 1,000 V commercial string limit for Auxin Solar AXN10M420W?

On 1,000 V commercial inverters at -10 C (41.82 V cold Voc), Auxin Solar AXN10M420W fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN10M420W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.