Heliene 144HC-565 M10 NTYP SL Bifacial is a 565.0 W STC (529.9 W PTC) Mono-c-Si solar module ranking #2,284 of 21,677 CEC listings (top 11.1%; higher than 88.9% of peers). It delivers 21.9% efficiency, 52.55 V Voc at 25 C, and 56.93 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 565.0 W
- PTC Wattage
- 529.9 W
- Voc @ 25C
- 52.55 V
- Efficiency
- 21.9%
How Does Heliene 144HC-565 M10 NTYP SL Bifacial Compare Against Peer CEC Listings?
Solar engineering breakdown for Heliene 144HC-565 M10 NTYP SL Bifacial: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Heliene and peers, Heliene 144HC-565 M10 NTYP SL Bifacial stands 155.0 W above the 410.0 W Mono-c-Si median and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,554-$2,545/yr in baseline US bill offset. Higher 52.55 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Heliene 144HC-565 M10 NTYP SL Bifacial Fall Across Listed CEC Models?
Distribution marker showing Heliene 144HC-565 M10 NTYP SL Bifacial (565.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Heliene 144HC-565 M10 NTYP SL Bifacial?
Dataset percentiles tracking Heliene 144HC-565 M10 NTYP SL Bifacial power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Heliene 144HC-565 M10 NTYP SL Bifacial?
Benchmark highlights for Heliene 144HC-565 M10 NTYP SL Bifacial covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 11.1% STC Output
565.0 W STC (+180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.9% Aperture Efficiency
Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.93 V at -10 C (569.3 V string) and 58.18 V at -20 C (10 max).
15 Panels = 8,475 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,948 W PTC; NEC 690.8 OCPD floor is 21.28 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.55 * (1 + (-0.238/100) * (-10 - 25)) = 56.93 V | OCPD = 1.56 * 13.64 = 21.28 A
Inputs from CEC Modules.csv for Heliene 144HC-565 M10 NTYP SL Bifacial: Voc=52.55 V, beta_Voc=-0.238%/C, Isc=13.64 A, STC=565.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (569.3 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Heliene 144HC-565 M10 NTYP SL Bifacial?
Official CEC datasheet figures for Heliene 144HC-565 M10 NTYP SL Bifacial (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 565.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 529.9 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.55 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.98 V / 12.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.238 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.9% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Heliene 144HC-565 M10 NTYP SL Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Heliene 144HC-565 M10 NTYP SL Bifacial modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.21 kW | 305 sq ft | $1,554 | $2,628 |
| 8 kW Class | 15 | 8.47 kW | 417 sq ft | $2,120 | $3,585 |
| 10 kW Class | 18 | 10.17 kW | 500 sq ft | $2,545 | $4,304 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Consolidated Heliene wattage variants sharing the Heliene 144HC-565 M10 NTYP SL Bifacial mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 144HC-555 M10 NTYP SL Bifacial | 555.0 W | 520.2 W | 52.26 V | 43.48 V | 21.51% |
| Heliene 144HC-560 M10 NTYP SL Bifacial | 560.0 W | 525.1 W | 52.4 V | 43.72 V | 21.71% |
| Heliene 144HC-565 M10 NTYP SL Bifacial | 565.0 W | 529.9 W | 52.55 V | 43.98 V | 21.9% |
| Heliene 144HC-570 M10 NTYP SL Bifacial | 570.0 W | 534.7 W | 52.69 V | 44.24 V | 22.09% |
How Many Heliene 144HC-565 M10 NTYP SL Bifacial Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 144HC-565 M10 NTYP SL Bifacial (56.93 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.18 V | 10 panels | 581.8 V | 17 panels |
| -10 C (14 F) | 56.93 V | 10 panels | 569.3 V | 17 panels |
| 0 C (32 F) | 55.68 V | 10 panels | 556.8 V | 17 panels |
| 25 C (77 F STC) | 52.55 V | 11 panels | 578.0 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-565 M10 NTYP SL Bifacial?
Competing CEC solar panels closest to Heliene 144HC-565 M10 NTYP SL Bifacial in nameplate wattage and Voc, starting with FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-565.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-565 FS GREEN ENERGIES PRIVATE LIMITED |
565.0 W | Tie (0 W) | 52.3 V | 22.07% | 95.0% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 GOLDI SUN PRIVATE LIMITED |
565.0 W | Tie (0 W) | 50.88 V | 21.9% | 94.5% |
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
565.0 W | Tie (0 W) | 50.7 V | 22.07% | 94.1% |
| Gautam Solar Pvt Ltd G2G1695-HAD Gautam Solar Pvt Ltd |
565.0 W | Tie (0 W) | 50.59 V | 22.01% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Heliene 144HC-565 M10 NTYP SL Bifacial?
Evaluate Heliene 144HC-565 M10 NTYP SL Bifacial (565.0 W STC, 52.55 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-565 M10 NTYP SL Bifacial reaches 58.18 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Heliene 144HC-565 M10 NTYP SL Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 144HC-565 M10 NTYP SL Bifacial 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-565.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 529.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 144HC-565 M10 NTYP SL Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Heliene 144HC-565 M10 NTYP SL Bifacial?
Multiplying Heliene 144HC-565 M10 NTYP SL Bifacial's 13.64 A short-circuit current by 1.56 equals 21.28 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Heliene 144HC-565 M10 NTYP SL Bifacial pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.93 V cold Voc at 14 F and handles 13.64 A Isc; string inverters cap Heliene 144HC-565 M10 NTYP SL Bifacial at 10 panels on 600 V.
Is Heliene 144HC-565 M10 NTYP SL Bifacial eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 144HC-565 M10 NTYP SL Bifacial rely on utility bill offset (~$2,120/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)