GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 is a 565.0 W STC (533.8 W PTC) Mono-c-Si solar module ranking #2,284 of 21,677 CEC listings (top 11.1%; higher than 88.9% of peers). It delivers 21.9% efficiency, 50.88 V Voc at 25 C, and 54.76 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 565.0 W
- PTC Wattage
- 533.8 W
- Voc @ 25C
- 50.88 V
- Efficiency
- 21.9%
How Does GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 Compare Against Peer CEC Listings?
Engineering position of GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 (565.0 W STC) vs. CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565 across 5,889 CEC Mono-c-Si solar modules.
Ranking #2,284 across 21,677 CEC solar panels (top 11.1%; higher than 88.9% of peers), GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 operates as a large-format commercial and ground-mount module sitting 155.0 W above the 410.0 W Mono-c-Si median. Higher 50.88 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677), 15 panels occupy 417 sq ft and offset roughly $2,120/yr at average US rates (or $3,585/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 Fall Across Listed CEC Models?
Plots GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 at 565.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565?
Benchmarks GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 on STC wattage, thermal PTC/STC retention, and 21.9 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 by GOLDI SUN PRIVATE LIMITED.
Top 11.1% STC Output
565.0 W STC (+180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.9% Aperture Efficiency
Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.76 V at -10 C (547.6 V string) and 55.87 V at -20 C (10 max).
15 Panels = 8,475 W STC
Occupies 38.7 m2 (417 sq ft) producing 8,007 W PTC; NEC 690.8 OCPD floor is 22.12 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.88 * (1 + (-0.218/100) * (-10 - 25)) = 54.76 V | OCPD = 1.56 * 14.18 = 22.12 A
Inputs from CEC Modules.csv for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565: Voc=50.88 V, beta_Voc=-0.218%/C, Isc=14.18 A, STC=565.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (547.6 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565?
Laboratory test ratings recorded for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 565.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 533.8 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.88 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.18 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.6 V / 13.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.218 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.9% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.21 kW | 305 sq ft | $1,554 | $2,628 |
| 8 kW Class | 15 | 8.47 kW | 417 sq ft | $2,120 | $3,585 |
| 10 kW Class | 18 | 10.17 kW | 500 sq ft | $2,545 | $4,304 |
Which Sibling Wattage & Trim Variants Belong to This GOLDI SUN PRIVATE LIMITED Series?
Sibling wattage bins and frame colors grouped with GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 under GOLDI SUN PRIVATE LIMITED to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-555 | 555.0 W | 524.2 W | 50.48 V | 42.2 V | 21.51% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-560 | 560.0 W | 529.0 W | 50.68 V | 42.4 V | 21.71% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 | 565.0 W | 533.8 W | 50.88 V | 42.6 V | 21.9% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-570 | 570.0 W | 538.7 W | 51.08 V | 42.8 V | 22.09% |
How Many GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 (beta_Voc -0.218%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.87 V | 10 panels | 558.7 V | 17 panels |
| -10 C (14 F) | 54.76 V | 10 panels | 547.6 V | 18 panels |
| 0 C (32 F) | 53.65 V | 11 panels | 590.1 V | 18 panels |
| 25 C (77 F STC) | 50.88 V | 11 panels | 559.7 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565?
Closest cross-brand CEC competitors to GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 matched near 565.0 W STC and 50.88 V Voc, led by CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
565.0 W | Tie (0 W) | 50.7 V | 22.07% | 94.1% |
| Gautam Solar Pvt Ltd G2G1695-HAD Gautam Solar Pvt Ltd |
565.0 W | Tie (0 W) | 50.59 V | 22.01% | 95.1% |
| Gautam Solar Pvt Ltd G2X1695N-UHAD Gautam Solar Pvt Ltd |
565.0 W | Tie (0 W) | 50.59 V | 21.98% | 94.8% |
| BLUESUN GROUP LIMITED BSM565M10-72HBD BLUESUN GROUP LIMITED |
565.0 W | Tie (0 W) | 49.84 V | 21.9% | 94.5% |
What Are the Design Limits and Best-Fit Uses for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565?
Evaluate GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 (565.0 W STC, 50.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 reaches 55.87 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 533.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 by GOLDI SUN PRIVATE LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
How many GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 panels fit on a 600 V winter solar string?
At -10 C (14 F), GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 cold Voc rises from 50.88 V to 54.76 V (beta_Voc -0.218%/C), capping a 600 V string at 10 panels (547.6 V).
How much roof area does an 8 kW array of GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 need?
An 8 kW DC system uses 15 GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 modules (8,475 W STC / 8,007 W PTC), covering roughly 417 sq ft and saving ~$2,120/yr at 18.54 c/kWh.
How does GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 compare against CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565?
GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 outputs 565.0 W STC (50.88 V Voc, rank #2,284 of 21,677), while CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565 delivers 565.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)