Skip to main content
WireAndSun
Calculators
CEC PV Module

BLUESUN GROUP LIMITED BSM565M10-72HBD — CEC Solar Module Specifications

Manufacturer: BLUESUN GROUP LIMITED Registry: CEC Verified Engineering Specification

BLUESUN GROUP LIMITED BSM565M10-72HBD is a 565.0 W STC (534.1 W PTC) Mono-c-Si solar module ranking #2,284 of 21,677 CEC listings (top 11.1%; higher than 88.9% of peers). It delivers 21.9% efficiency, 49.84 V Voc at 25 C, and 54.11 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
565.0 W
PTC Wattage
534.1 W
Voc @ 25C
49.84 V
Efficiency
21.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does BLUESUN GROUP LIMITED BSM565M10-72HBD Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for BLUESUN GROUP LIMITED BSM565M10-72HBD (Mono-c-Si) residential solar systems.

BLUESUN GROUP LIMITED BSM565M10-72HBD delivers 219.0 W/m2 (1.99 percentage points above 19.91% CEC median) and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 55.33 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Gautam Solar Pvt Ltd G2G1695-HAD (565.0 W).

Where Does BLUESUN GROUP LIMITED BSM565M10-72HBD Fall Across Listed CEC Models?

Comparison of BLUESUN GROUP LIMITED BSM565M10-72HBD (565.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where BLUESUN GROUP LIMITED BSM565M10-72HBD (565.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCBLUESUN GROUP LIMI: 565.0 W

What Dataset Percentiles Define BLUESUN GROUP LIMITED BSM565M10-72HBD?

Relative ranking of BLUESUN GROUP LIMITED BSM565M10-72HBD across nameplate watts, 94.5% PTC thermal ratio, and module aperture efficiency.

BLUESUN GROUP LIMITED BSM565M10-72HBD Engineering BenchmarksPercentile comparison of BLUESUN GROUP LIMITED BSM565M10-72HBD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage565.0 WPTC/STC Retention94.5%Module Efficiency21.9%

What Do the Dataset Ranks Show for BLUESUN GROUP LIMITED BSM565M10-72HBD?

Summary of BLUESUN GROUP LIMITED BSM565M10-72HBD output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,284 / 21,677

Top 11.1% STC Output

565.0 W STC (+180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,316

21.9% Aperture Efficiency

Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.11 V at -10 C (595.2 V string) and 55.33 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,475 W STC

Occupies 38.7 m2 (417 sq ft) producing 8,012 W PTC; NEC 690.8 OCPD floor is 22.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.84 * (1 + (-0.245/100) * (-10 - 25)) = 54.11 V | OCPD = 1.56 * 14.37 = 22.42 A

Inputs from CEC Modules.csv for BLUESUN GROUP LIMITED BSM565M10-72HBD: Voc=49.84 V, beta_Voc=-0.245%/C, Isc=14.37 A, STC=565.0 W, Area=2.58 m2.

Result: 11 panels max on 600 V (595.2 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for BLUESUN GROUP LIMITED BSM565M10-72HBD?

Complete CEC test sheet for BLUESUN GROUP LIMITED BSM565M10-72HBD including Isc (14.37 A), Voc (49.84 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for BLUESUN GROUP LIMITED BSM565M10-72HBD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 565.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 534.1 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.84 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.01 V / 13.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.9% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many BLUESUN GROUP LIMITED BSM565M10-72HBD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using BLUESUN GROUP LIMITED BSM565M10-72HBD.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.21 kW 305 sq ft $1,554 $2,628
8 kW Class 15 8.47 kW 417 sq ft $2,120 $3,585
10 kW Class 18 10.17 kW 500 sq ft $2,545 $4,304

How Many BLUESUN GROUP LIMITED BSM565M10-72HBD Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for BLUESUN GROUP LIMITED BSM565M10-72HBD (49.84 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.84V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.33 V 10 panels 553.3 V 18 panels
-10 C (14 F) 54.11 V 11 panels 595.2 V 18 panels
0 C (32 F) 52.89 V 11 panels 581.8 V 18 panels
25 C (77 F STC) 49.84 V 12 panels 598.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to BLUESUN GROUP LIMITED BSM565M10-72HBD?

Four comparable CEC modules such as Gautam Solar Pvt Ltd G2G1695-HAD (565.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gautam Solar Pvt Ltd G2G1695-HAD
Gautam Solar Pvt Ltd
565.0 W Tie (0 W) 50.59 V 22.01% 95.1%
Gautam Solar Pvt Ltd G2X1695N-UHAD
Gautam Solar Pvt Ltd
565.0 W Tie (0 W) 50.59 V 21.98% 94.8%
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
565.0 W Tie (0 W) 50.7 V 22.07% 94.1%
GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565
GOLDI SUN PRIVATE LIMITED
565.0 W Tie (0 W) 50.88 V 21.9% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for BLUESUN GROUP LIMITED BSM565M10-72HBD?

Evaluate BLUESUN GROUP LIMITED BSM565M10-72HBD (565.0 W STC, 49.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), BLUESUN GROUP LIMITED BSM565M10-72HBD reaches 55.33 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of BLUESUN GROUP LIMITED BSM565M10-72HBD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

BLUESUN GROUP LIMITED BSM565M10-72HBD 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Gautam Solar Pvt Ltd G2G1695-HAD.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 534.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for BLUESUN GROUP LIMITED BSM565M10-72HBD by BLUESUN GROUP LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many BLUESUN GROUP LIMITED BSM565M10-72HBD panels fit on a 600 V winter solar string?

At -10 C (14 F), BLUESUN GROUP LIMITED BSM565M10-72HBD cold Voc rises from 49.84 V to 54.11 V (beta_Voc -0.245%/C), capping a 600 V string at 11 panels (595.2 V).

How much roof area does an 8 kW array of BLUESUN GROUP LIMITED BSM565M10-72HBD need?

An 8 kW DC system uses 15 BLUESUN GROUP LIMITED BSM565M10-72HBD modules (8,475 W STC / 8,012 W PTC), covering roughly 417 sq ft and saving ~$2,120/yr at 18.54 c/kWh.

How does BLUESUN GROUP LIMITED BSM565M10-72HBD compare against Gautam Solar Pvt Ltd G2G1695-HAD?

BLUESUN GROUP LIMITED BSM565M10-72HBD outputs 565.0 W STC (49.84 V Voc, rank #2,284 of 21,677), while Gautam Solar Pvt Ltd G2G1695-HAD delivers 565.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.