GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 is a 610.0 W STC (573.9 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.59% efficiency, 49.0 V Voc at 25 C, and 52.98 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 573.9 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 22.59%
How Does GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 Compare Against Peer CEC Listings?
Engineering position of GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 (610.0 W STC) vs. Mundra Solar PV Limited (Adani) AB-G12R-132-610 across 5,889 CEC Mono-c-Si solar modules.
Ranking #1,104 across 21,677 CEC solar panels (top 5.6%; higher than 94.4% of peers), GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 operates as a large-format commercial and ground-mount module sitting 200.0 W above the 410.0 W Mono-c-Si median. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), 14 panels occupy 407 sq ft and offset roughly $2,137/yr at average US rates (or $3,614/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 Fall Across Listed CEC Models?
Plots GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 at 610.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610?
Benchmarks GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 on STC wattage, thermal PTC/STC retention, and 22.59 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 by GOLDI SUN PRIVATE LIMITED.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.59% Aperture Efficiency
Power density 225.9 W/m2 (2.68 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.98 V at -10 C (582.8 V string) and 54.12 V at -20 C (11 max).
14 Panels = 8,540 W STC
Occupies 37.8 m2 (407 sq ft) producing 8,035 W PTC; NEC 690.8 OCPD floor is 24.74 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.232/100) * (-10 - 25)) = 52.98 V | OCPD = 1.56 * 15.86 = 24.74 A
Inputs from CEC Modules.csv for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610: Voc=49.0 V, beta_Voc=-0.232%/C, Isc=15.86 A, STC=610.0 W, Area=2.7 m2.
Result: 11 panels max on 600 V (582.8 V); 14 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610?
Laboratory test ratings recorded for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 573.9 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.7 V / 14.99 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.59% (2.7 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (407 sq ft at 8 kW), and estimated Year-1 electric bill offset for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 291 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 407 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 494 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This GOLDI SUN PRIVATE LIMITED Series?
Sibling wattage bins and frame colors grouped with GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 under GOLDI SUN PRIVATE LIMITED to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-600 | 600.0 W | 564.3 W | 48.4 V | 40.3 V | 22.22% |
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-605 | 605.0 W | 569.1 W | 48.7 V | 40.5 V | 22.41% |
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 | 610.0 W | 573.9 W | 49.0 V | 40.7 V | 22.59% |
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-615 | 615.0 W | 578.8 W | 49.3 V | 40.9 V | 22.78% |
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-620 | 620.0 W | 583.6 W | 49.6 V | 41.1 V | 22.96% |
How Many GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 (beta_Voc -0.232%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.12 V | 11 panels | 595.3 V | 18 panels |
| -10 C (14 F) | 52.98 V | 11 panels | 582.8 V | 18 panels |
| 0 C (32 F) | 51.84 V | 11 panels | 570.2 V | 19 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610?
Closest cross-brand CEC competitors to GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 matched near 610.0 W STC and 49.0 V Voc, led by Mundra Solar PV Limited (Adani) AB-G12R-132-610.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Mundra Solar PV Limited (Adani) AB-G12R-132-610 Mundra Solar PV Limited (Adani) |
610.0 W | Tie (0 W) | 49.0 V | 22.76% | 94.5% |
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
610.0 W | Tie (0 W) | 48.7 V | 22.76% | 94.5% |
| CSI Solar Co Ltd CS62-66TB-610HR CSI Solar Co Ltd |
610.0 W | Tie (0 W) | 49.3 V | 23.28% | 94.7% |
| Jinko Solar Co Ltd JKM610N-66HL4M-BDV Jinko Solar Co Ltd |
610.0 W | Tie (0 W) | 48.68 V | 22.59% | 94.2% |
What Are the Design Limits and Best-Fit Uses for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610?
Evaluate GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 (610.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 reaches 54.12 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 8 kW Residential Fit
Needs 14 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Mundra Solar PV Limited (Adani) AB-G12R-132-610.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 573.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 by GOLDI SUN PRIVATE LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
How many GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 panels fit on a 600 V winter solar string?
At -10 C (14 F), GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 cold Voc rises from 49.0 V to 52.98 V (beta_Voc -0.232%/C), capping a 600 V string at 11 panels (582.8 V).
How much roof area does an 8 kW array of GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 need?
An 8 kW DC system uses 14 GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 modules (8,540 W STC / 8,035 W PTC), covering roughly 407 sq ft and saving ~$2,137/yr at 18.54 c/kWh.
How does GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 compare against Mundra Solar PV Limited (Adani) AB-G12R-132-610?
GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 outputs 610.0 W STC (49.0 V Voc, rank #1,104 of 21,677), while Mundra Solar PV Limited (Adani) AB-G12R-132-610 delivers 610.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)