Mundra Solar PV Limited (Adani) AB-G12R-132-610 is a 610.0 W STC (576.2 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.76% efficiency, 49.0 V Voc at 25 C, and 52.98 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 576.2 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 22.76%
How Does Mundra Solar PV Limited (Adani) AB-G12R-132-610 Compare Against Peer CEC Listings?
Solar engineering breakdown for Mundra Solar PV Limited (Adani) AB-G12R-132-610: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Mundra Solar PV Limited (Adani) and peers, Mundra Solar PV Limited (Adani) AB-G12R-132-610 stands 200.0 W above the 410.0 W Mono-c-Si median and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,527-$2,596/yr in baseline US bill offset. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Mundra Solar PV Limited (Adani) AB-G12R-132-610 Fall Across Listed CEC Models?
Distribution marker showing Mundra Solar PV Limited (Adani) AB-G12R-132-610 (610.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Dataset percentiles tracking Mundra Solar PV Limited (Adani) AB-G12R-132-610 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Benchmark highlights for Mundra Solar PV Limited (Adani) AB-G12R-132-610 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.76% Aperture Efficiency
Power density 227.6 W/m2 (2.85 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.98 V at -10 C (582.8 V string) and 54.12 V at -20 C (11 max).
14 Panels = 8,540 W STC
Occupies 37.5 m2 (404 sq ft) producing 8,067 W PTC; NEC 690.8 OCPD floor is 24.74 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.232/100) * (-10 - 25)) = 52.98 V | OCPD = 1.56 * 15.86 = 24.74 A
Inputs from CEC Modules.csv for Mundra Solar PV Limited (Adani) AB-G12R-132-610: Voc=49.0 V, beta_Voc=-0.232%/C, Isc=15.86 A, STC=610.0 W, Area=2.68 m2.
Result: 11 panels max on 600 V (582.8 V); 14 panels for 8 kW (404 sq ft).
What Are the Published CEC Specifications for Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Official CEC datasheet figures for Mundra Solar PV Limited (Adani) AB-G12R-132-610 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 576.2 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.8 V / 14.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.76% (2.68 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Mundra Solar PV Limited (Adani) AB-G12R-132-610 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Mundra Solar PV Limited (Adani) AB-G12R-132-610 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 288 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 404 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 490 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This Mundra Solar PV Limited (Adani) Series?
Consolidated Mundra Solar PV Limited (Adani) wattage variants sharing the Mundra Solar PV Limited (Adani) AB-G12R-132-610 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Mundra Solar PV Limited (Adani) AB-G12R-132-600 | 600.0 W | 566.5 W | 48.4 V | 40.3 V | 22.39% |
| Mundra Solar PV Limited (Adani) AB-G12R-132-605 | 605.0 W | 571.4 W | 48.7 V | 40.5 V | 22.57% |
| Mundra Solar PV Limited (Adani) AB-G12R-132-610 | 610.0 W | 576.2 W | 49.0 V | 40.8 V | 22.76% |
| Mundra Solar PV Limited (Adani) AB-G12R-132-615 | 615.0 W | 581.0 W | 49.3 V | 41.1 V | 22.95% |
| Mundra Solar PV Limited (Adani) AB-G12R-132-620 | 620.0 W | 585.9 W | 49.6 V | 41.4 V | 23.13% |
How Many Mundra Solar PV Limited (Adani) AB-G12R-132-610 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Mundra Solar PV Limited (Adani) AB-G12R-132-610 (52.98 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.12 V | 11 panels | 595.3 V | 18 panels |
| -10 C (14 F) | 52.98 V | 11 panels | 582.8 V | 18 panels |
| 0 C (32 F) | 51.84 V | 11 panels | 570.2 V | 19 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Competing CEC solar panels closest to Mundra Solar PV Limited (Adani) AB-G12R-132-610 in nameplate wattage and Voc, starting with GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610 GOLDI SUN PRIVATE LIMITED |
610.0 W | Tie (0 W) | 49.0 V | 22.59% | 94.1% |
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
610.0 W | Tie (0 W) | 48.7 V | 22.76% | 94.5% |
| CSI Solar Co Ltd CS62-66TB-610HR CSI Solar Co Ltd |
610.0 W | Tie (0 W) | 49.3 V | 23.28% | 94.7% |
| Jinko Solar Co Ltd JKM610N-66HL4M-BDV Jinko Solar Co Ltd |
610.0 W | Tie (0 W) | 48.68 V | 22.59% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Evaluate Mundra Solar PV Limited (Adani) AB-G12R-132-610 (610.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar PV Limited (Adani) AB-G12R-132-610 reaches 54.12 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Mundra Solar PV Limited (Adani) AB-G12R-132-610 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mundra Solar PV Limited (Adani) AB-G12R-132-610 8 kW Residential Fit
Needs 14 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 576.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mundra Solar PV Limited (Adani) AB-G12R-132-610 by Mundra Solar PV Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Mundra Solar PV Limited (Adani) AB-G12R-132-610?
Multiplying Mundra Solar PV Limited (Adani) AB-G12R-132-610's 15.86 A short-circuit current by 1.56 equals 24.74 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Mundra Solar PV Limited (Adani) AB-G12R-132-610 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.98 V cold Voc at 14 F and handles 15.86 A Isc; string inverters cap Mundra Solar PV Limited (Adani) AB-G12R-132-610 at 11 panels on 600 V.
Is Mundra Solar PV Limited (Adani) AB-G12R-132-610 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mundra Solar PV Limited (Adani) AB-G12R-132-610 rely on utility bill offset (~$2,137/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)