Skip to main content
WireAndSun
Calculators
CEC PV Module

Mundra Solar PV Limited (Adani) AB-G12R-132-610 — CEC Solar Module Specifications

Manufacturer: Mundra Solar PV Limited (Adani) Registry: CEC Verified Engineering Specification

Mundra Solar PV Limited (Adani) AB-G12R-132-610 is a 610.0 W STC (576.2 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.76% efficiency, 49.0 V Voc at 25 C, and 52.98 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
610.0 W
PTC Wattage
576.2 W
Voc @ 25C
49.0 V
Efficiency
22.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mundra Solar PV Limited (Adani) AB-G12R-132-610 Compare Against Peer CEC Listings?

Solar engineering breakdown for Mundra Solar PV Limited (Adani) AB-G12R-132-610: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Mundra Solar PV Limited (Adani) and peers, Mundra Solar PV Limited (Adani) AB-G12R-132-610 stands 200.0 W above the 410.0 W Mono-c-Si median and strong 94.5% PTC-to-STC heat retention (#2,573 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,527-$2,596/yr in baseline US bill offset. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Mundra Solar PV Limited (Adani) AB-G12R-132-610 Fall Across Listed CEC Models?

Distribution marker showing Mundra Solar PV Limited (Adani) AB-G12R-132-610 (610.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mundra Solar PV Limited (Adani) AB-G12R-132-610 (610.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMundra Solar PV Li: 610.0 W

What Dataset Percentiles Define Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Dataset percentiles tracking Mundra Solar PV Limited (Adani) AB-G12R-132-610 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Mundra Solar PV Limited (Adani) AB-G12R-132-610 Engineering BenchmarksPercentile comparison of Mundra Solar PV Limited (Adani) AB-G12R-132-610 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage610.0 WPTC/STC Retention94.5%Module Efficiency22.76%

What Do the Dataset Ranks Show for Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Benchmark highlights for Mundra Solar PV Limited (Adani) AB-G12R-132-610 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,104 / 21,677

Top 5.6% STC Output

610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,531

22.76% Aperture Efficiency

Power density 227.6 W/m2 (2.85 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.98 V at -10 C (582.8 V string) and 54.12 V at -20 C (11 max).

8 kW Reference Array

14 Panels = 8,540 W STC

Occupies 37.5 m2 (404 sq ft) producing 8,067 W PTC; NEC 690.8 OCPD floor is 24.74 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.0 * (1 + (-0.232/100) * (-10 - 25)) = 52.98 V | OCPD = 1.56 * 15.86 = 24.74 A

Inputs from CEC Modules.csv for Mundra Solar PV Limited (Adani) AB-G12R-132-610: Voc=49.0 V, beta_Voc=-0.232%/C, Isc=15.86 A, STC=610.0 W, Area=2.68 m2.

Result: 11 panels max on 600 V (582.8 V); 14 panels for 8 kW (404 sq ft).

What Are the Published CEC Specifications for Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Official CEC datasheet figures for Mundra Solar PV Limited (Adani) AB-G12R-132-610 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Mundra Solar PV Limited (Adani) AB-G12R-132-610.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 610.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 576.2 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.8 V / 14.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.76% (2.68 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Mundra Solar PV Limited (Adani) AB-G12R-132-610 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mundra Solar PV Limited (Adani) AB-G12R-132-610 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.1 kW 288 sq ft $1,527 $2,582
8 kW Class 14 8.54 kW 404 sq ft $2,137 $3,614
10 kW Class 17 10.37 kW 490 sq ft $2,596 $4,389

Which Sibling Wattage & Trim Variants Belong to This Mundra Solar PV Limited (Adani) Series?

Consolidated Mundra Solar PV Limited (Adani) wattage variants sharing the Mundra Solar PV Limited (Adani) AB-G12R-132-610 mechanical and cell layout.

Sibling CEC listings grouped into the Mundra Solar PV Limited (Adani) AB-G12R-132-610 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mundra Solar PV Limited (Adani) AB-G12R-132-600 600.0 W 566.5 W 48.4 V 40.3 V 22.39%
Mundra Solar PV Limited (Adani) AB-G12R-132-605 605.0 W 571.4 W 48.7 V 40.5 V 22.57%
Mundra Solar PV Limited (Adani) AB-G12R-132-610 610.0 W 576.2 W 49.0 V 40.8 V 22.76%
Mundra Solar PV Limited (Adani) AB-G12R-132-615 615.0 W 581.0 W 49.3 V 41.1 V 22.95%
Mundra Solar PV Limited (Adani) AB-G12R-132-620 620.0 W 585.9 W 49.6 V 41.4 V 23.13%

How Many Mundra Solar PV Limited (Adani) AB-G12R-132-610 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mundra Solar PV Limited (Adani) AB-G12R-132-610 (52.98 V at 14 F).

Computed from Voc=49.0V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.12 V 11 panels 595.3 V 18 panels
-10 C (14 F) 52.98 V 11 panels 582.8 V 18 panels
0 C (32 F) 51.84 V 11 panels 570.2 V 19 panels
25 C (77 F STC) 49.0 V 12 panels 588.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Competing CEC solar panels closest to Mundra Solar PV Limited (Adani) AB-G12R-132-610 in nameplate wattage and Voc, starting with GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610
GOLDI SUN PRIVATE LIMITED
610.0 W Tie (0 W) 49.0 V 22.59% 94.1%
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
610.0 W Tie (0 W) 48.7 V 22.76% 94.5%
CSI Solar Co Ltd CS62-66TB-610HR
CSI Solar Co Ltd
610.0 W Tie (0 W) 49.3 V 23.28% 94.7%
Jinko Solar Co Ltd JKM610N-66HL4M-BDV
Jinko Solar Co Ltd
610.0 W Tie (0 W) 48.68 V 22.59% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Evaluate Mundra Solar PV Limited (Adani) AB-G12R-132-610 (610.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar PV Limited (Adani) AB-G12R-132-610 reaches 54.12 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Mundra Solar PV Limited (Adani) AB-G12R-132-610 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mundra Solar PV Limited (Adani) AB-G12R-132-610 8 kW Residential Fit

Needs 14 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 576.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mundra Solar PV Limited (Adani) AB-G12R-132-610 by Mundra Solar PV Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Mundra Solar PV Limited (Adani) AB-G12R-132-610?

Multiplying Mundra Solar PV Limited (Adani) AB-G12R-132-610's 15.86 A short-circuit current by 1.56 equals 24.74 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Mundra Solar PV Limited (Adani) AB-G12R-132-610 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.98 V cold Voc at 14 F and handles 15.86 A Isc; string inverters cap Mundra Solar PV Limited (Adani) AB-G12R-132-610 at 11 panels on 600 V.

Is Mundra Solar PV Limited (Adani) AB-G12R-132-610 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mundra Solar PV Limited (Adani) AB-G12R-132-610 rely on utility bill offset (~$2,137/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.