Mundra Solar PV Limited (Adani) ASB-M10-144-560 is a 560.0 W STC (527.9 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.79% efficiency, 50.6 V Voc at 25 C, and 54.83 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 527.9 W
- Voc @ 25C
- 50.6 V
- Efficiency
- 21.79%
How Does Mundra Solar PV Limited (Adani) ASB-M10-144-560 Compare Against Peer CEC Listings?
Solar engineering breakdown for Mundra Solar PV Limited (Adani) ASB-M10-144-560: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 560.0 W STC and 527.9 W PTC, Mundra Solar PV Limited (Adani) ASB-M10-144-560 sits +175.0 W vs all-CEC median (top 11.8%; higher than 88.2% of peers) among 21,677 listed modules. Power density reaches 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). Higher 50.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer EMMVEE Photovoltaic Power Private Limited E560HCBG144-T rates 560.0 W.
Where Does Mundra Solar PV Limited (Adani) ASB-M10-144-560 Fall Across Listed CEC Models?
Distribution marker showing Mundra Solar PV Limited (Adani) ASB-M10-144-560 (560.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Mundra Solar PV Limited (Adani) ASB-M10-144-560?
Dataset percentiles tracking Mundra Solar PV Limited (Adani) ASB-M10-144-560 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Mundra Solar PV Limited (Adani) ASB-M10-144-560?
Benchmark highlights for Mundra Solar PV Limited (Adani) ASB-M10-144-560 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.79% Aperture Efficiency
Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.83 V at -10 C (548.3 V string) and 56.04 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,918 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.6 * (1 + (-0.239/100) * (-10 - 25)) = 54.83 V | OCPD = 1.56 * 13.99 = 21.82 A
Inputs from CEC Modules.csv for Mundra Solar PV Limited (Adani) ASB-M10-144-560: Voc=50.6 V, beta_Voc=-0.239%/C, Isc=13.99 A, STC=560.0 W, Area=2.57 m2.
Result: 10 panels max on 600 V (548.3 V); 15 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Mundra Solar PV Limited (Adani) ASB-M10-144-560?
Official CEC datasheet figures for Mundra Solar PV Limited (Adani) ASB-M10-144-560 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 527.9 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.4 V / 13.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.239 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.79% (2.57 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Mundra Solar PV Limited (Adani) ASB-M10-144-560 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Mundra Solar PV Limited (Adani) ASB-M10-144-560 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 304 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 415 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 498 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Mundra Solar PV Limited (Adani) Series?
Consolidated Mundra Solar PV Limited (Adani) wattage variants sharing the Mundra Solar PV Limited (Adani) ASB-M10-144-560 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Mundra Solar PV Limited (Adani) ASB-M10-144-550 | 550.0 W | 518.2 W | 50.2 V | 42.0 V | 21.4% |
| Mundra Solar PV Limited (Adani) ASB-M10-144-555 | 555.0 W | 523.0 W | 50.4 V | 42.2 V | 21.6% |
| Mundra Solar PV Limited (Adani) ASB-M10-144-560 | 560.0 W | 527.9 W | 50.6 V | 42.4 V | 21.79% |
| Mundra Solar PV Limited (Adani) ASB-M10-144-565 | 565.0 W | 532.7 W | 50.8 V | 42.6 V | 21.98% |
| Mundra Solar PV Limited (Adani) ASB-M10-144-570 | 570.0 W | 537.5 W | 51.0 V | 42.8 V | 22.18% |
How Many Mundra Solar PV Limited (Adani) ASB-M10-144-560 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Mundra Solar PV Limited (Adani) ASB-M10-144-560 (54.83 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.04 V | 10 panels | 560.4 V | 17 panels |
| -10 C (14 F) | 54.83 V | 10 panels | 548.3 V | 18 panels |
| 0 C (32 F) | 53.62 V | 11 panels | 589.8 V | 18 panels |
| 25 C (77 F STC) | 50.6 V | 11 panels | 556.6 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Mundra Solar PV Limited (Adani) ASB-M10-144-560?
Competing CEC solar panels closest to Mundra Solar PV Limited (Adani) ASB-M10-144-560 in nameplate wattage and Voc, starting with EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E560HCBG144-T EMMVEE Photovoltaic Power Private Limited |
560.0 W | Tie (0 W) | 50.67 V | 21.88% | 93.4% |
| EMMVEE Photovoltaic Power Private Limited E560HCBT144-T EMMVEE Photovoltaic Power Private Limited |
560.0 W | Tie (0 W) | 50.67 V | 21.88% | 94.5% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560 Chint New Energy Technology Co Ltd |
560.0 W | Tie (0 W) | 50.5 V | 21.71% | 94.6% |
| Gautam Solar Pvt Ltd G2G1680-HAD Gautam Solar Pvt Ltd |
560.0 W | Tie (0 W) | 50.44 V | 21.81% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Mundra Solar PV Limited (Adani) ASB-M10-144-560?
Evaluate Mundra Solar PV Limited (Adani) ASB-M10-144-560 (560.0 W STC, 50.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar PV Limited (Adani) ASB-M10-144-560 reaches 56.04 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 415 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Mundra Solar PV Limited (Adani) ASB-M10-144-560 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mundra Solar PV Limited (Adani) ASB-M10-144-560 8 kW Residential Fit
Needs 15 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 527.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mundra Solar PV Limited (Adani) ASB-M10-144-560 by Mundra Solar PV Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.
How many Mundra Solar PV Limited (Adani) ASB-M10-144-560 panels fit on a 600 V winter solar string?
At -10 C (14 F), Mundra Solar PV Limited (Adani) ASB-M10-144-560 cold Voc rises from 50.6 V to 54.83 V (beta_Voc -0.239%/C), capping a 600 V string at 10 panels (548.3 V).
How much roof area does an 8 kW array of Mundra Solar PV Limited (Adani) ASB-M10-144-560 need?
An 8 kW DC system uses 15 Mundra Solar PV Limited (Adani) ASB-M10-144-560 modules (8,400 W STC / 7,918 W PTC), covering roughly 415 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does Mundra Solar PV Limited (Adani) ASB-M10-144-560 compare against EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Mundra Solar PV Limited (Adani) ASB-M10-144-560 outputs 560.0 W STC (50.6 V Voc, rank #2,404 of 21,677), while EMMVEE Photovoltaic Power Private Limited E560HCBG144-T delivers 560.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)