Manufacturer: Mundra Solar PV Limited (Adani) Registry: CEC Verified Engineering Specification

Mundra Solar PV Limited (Adani) ASB-7-380 is a 380.0 W STC (348.7 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 18.91% efficiency, 48.19 V Voc at 25 C, and 52.93 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
348.7 W
Voc @ 25C
48.19 V
Efficiency
18.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mundra Solar PV Limited (Adani) ASB-7-380 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Mundra Solar PV Limited (Adani) ASB-7-380 (Mono-c-Si) residential solar systems.

Mundra Solar PV Limited (Adani) ASB-7-380 delivers 189.1 W/m2 (1.00 percentage points below 19.91% CEC median) and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (476 sq ft). At -4 F (-20 C), string voltage climbs to 54.28 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Auxin Solar AXN6M612B380 (380.0 W).

Where Does Mundra Solar PV Limited (Adani) ASB-7-380 Fall Across Listed CEC Models?

Comparison of Mundra Solar PV Limited (Adani) ASB-7-380 (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mundra Solar PV Limited (Adani) ASB-7-380 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMundra Solar PV Li: 380.0 W

What Dataset Percentiles Define Mundra Solar PV Limited (Adani) ASB-7-380?

Relative ranking of Mundra Solar PV Limited (Adani) ASB-7-380 across nameplate watts, 91.8% PTC thermal ratio, and module aperture efficiency.

Mundra Solar PV Limited (Adani) ASB-7-380 Engineering BenchmarksPercentile comparison of Mundra Solar PV Limited (Adani) ASB-7-380 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention91.8%Module Efficiency18.91%

What Do the Dataset Ranks Show for Mundra Solar PV Limited (Adani) ASB-7-380?

Summary of Mundra Solar PV Limited (Adani) ASB-7-380 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,626

18.91% Aperture Efficiency

Power density 189.1 W/m2 (1.00 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.93 V at -10 C (582.2 V string) and 54.28 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,671 W PTC; NEC 690.8 OCPD floor is 15.69 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.19 * (1 + (-0.281/100) * (-10 - 25)) = 52.93 V | OCPD = 1.56 * 10.06 = 15.69 A

Inputs from CEC Modules.csv for Mundra Solar PV Limited (Adani) ASB-7-380: Voc=48.19 V, beta_Voc=-0.281%/C, Isc=10.06 A, STC=380.0 W, Area=2.01 m2.

Result: 11 panels max on 600 V (582.2 V); 22 panels for 8 kW (476 sq ft).

What Are the Published CEC Specifications for Mundra Solar PV Limited (Adani) ASB-7-380?

Complete CEC test sheet for Mundra Solar PV Limited (Adani) ASB-7-380 including Isc (10.06 A), Voc (48.19 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Mundra Solar PV Limited (Adani) ASB-7-380.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 348.7 W (91.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.19 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.06 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.5 V / 9.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.91% (2.01 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Mundra Solar PV Limited (Adani) ASB-7-380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Mundra Solar PV Limited (Adani) ASB-7-380.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 346 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 476 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 584 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Mundra Solar PV Limited (Adani) Series?

Related Mundra Solar PV Limited (Adani) power steps and black/silver trims consolidated into this Mundra Solar PV Limited (Adani) ASB-7-380 series guide.

Sibling CEC listings grouped into the Mundra Solar PV Limited (Adani) ASB-7-380 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mundra Solar PV Limited (Adani) ASB-7-375 377.1 W 346.0 W 48.75 V 40.42 V 18.76%
Mundra Solar PV Limited (Adani) ASB-7-380 380.0 W 348.7 W 48.19 V 39.5 V 18.91%
Mundra Solar PV Limited (Adani) ASB-7-385 385.0 W 353.5 W 48.9 V 39.66 V 19.15%

How Many Mundra Solar PV Limited (Adani) ASB-7-380 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Mundra Solar PV Limited (Adani) ASB-7-380 (48.19 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.19V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.28 V 11 panels 597.1 V 18 panels
-10 C (14 F) 52.93 V 11 panels 582.2 V 18 panels
0 C (32 F) 51.58 V 11 panels 567.4 V 19 panels
25 C (77 F STC) 48.19 V 12 panels 578.3 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Mundra Solar PV Limited (Adani) ASB-7-380?

Four comparable CEC modules such as Auxin Solar AXN6M612B380 (380.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
CSI Solar Co Ltd CS3U-385MB-AG
CSI Solar Co Ltd
385.0 W +5.0 W 48.0 V 19.85% 93.9%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mundra Solar PV Limited (Adani) ASB-7-380?

Evaluate Mundra Solar PV Limited (Adani) ASB-7-380 (380.0 W STC, 48.19 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar PV Limited (Adani) ASB-7-380 reaches 54.28 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (476 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mundra Solar PV Limited (Adani) ASB-7-380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mundra Solar PV Limited (Adani) ASB-7-380 8 kW Residential Fit

Needs 22 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B380.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 348.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mundra Solar PV Limited (Adani) ASB-7-380 by Mundra Solar PV Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.

How many Mundra Solar PV Limited (Adani) ASB-7-380 panels fit on a 600 V winter solar string?

At -10 C (14 F), Mundra Solar PV Limited (Adani) ASB-7-380 cold Voc rises from 48.19 V to 52.93 V (beta_Voc -0.281%/C), capping a 600 V string at 11 panels (582.2 V).

How much roof area does an 8 kW array of Mundra Solar PV Limited (Adani) ASB-7-380 need?

An 8 kW DC system uses 22 Mundra Solar PV Limited (Adani) ASB-7-380 modules (8,360 W STC / 7,671 W PTC), covering roughly 476 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does Mundra Solar PV Limited (Adani) ASB-7-380 compare against Auxin Solar AXN6M612B380?

Mundra Solar PV Limited (Adani) ASB-7-380 outputs 380.0 W STC (48.19 V Voc, rank #11,043 of 21,677), while Auxin Solar AXN6M612B380 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.