Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6M612B380 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6M612B380 is a 380.0 W STC (353.8 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.3% efficiency, 47.94 V Voc at 25 C, and 52.59 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
353.8 W
Voc @ 25C
47.94 V
Efficiency
19.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6M612B380 Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN6M612B380 (380.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.

Ranking #11,043 across 21,677 CEC solar panels (below all-CEC median; higher than 47.6% of peers), Auxin Solar AXN6M612B380 operates as a compact residential or specialty off-grid module sitting 30.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.94 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), 22 panels occupy 466 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Auxin Solar AXN6M612B380 Fall Across Listed CEC Models?

Plots Auxin Solar AXN6M612B380 at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6M612B380 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6M6: 380.0 W

What Dataset Percentiles Define Auxin Solar AXN6M612B380?

Benchmarks Auxin Solar AXN6M612B380 on STC wattage, thermal PTC/STC retention, and 19.3 aperture conversion efficiency against CEC peers.

Auxin Solar AXN6M612B380 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6M612B380 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.1%Module Efficiency19.3%

What Do the Dataset Ranks Show for Auxin Solar AXN6M612B380?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M612B380 by Auxin Solar.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,724

19.3% Aperture Efficiency

Power density 193.0 W/m2 (0.61 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.59 V at -10 C (578.5 V string) and 53.92 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 43.3 m2 (466 sq ft) producing 7,784 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.94 * (1 + (-0.277/100) * (-10 - 25)) = 52.59 V | OCPD = 1.56 * 10.35 = 16.15 A

Inputs from CEC Modules.csv for Auxin Solar AXN6M612B380: Voc=47.94 V, beta_Voc=-0.277%/C, Isc=10.35 A, STC=380.0 W, Area=1.969 m2.

Result: 11 panels max on 600 V (578.5 V); 22 panels for 8 kW (466 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6M612B380?

Laboratory test ratings recorded for Auxin Solar AXN6M612B380 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6M612B380.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 353.8 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.94 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.94 V / 9.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.3% (1.969 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Auxin Solar AXN6M612B380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (466 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M612B380.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 339 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 466 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 572 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M612B380 under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN6M612B380 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6M612B375 375.0 W 349.0 W 47.85 V 38.86 V 19.05%
Auxin Solar AXN6M612B380 380.0 W 353.8 W 47.94 V 38.94 V 19.3%

How Many Auxin Solar AXN6M612B380 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN6M612B380 (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.94V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.92 V 11 panels 593.1 V 18 panels
-10 C (14 F) 52.59 V 11 panels 578.5 V 19 panels
0 C (32 F) 51.26 V 11 panels 563.9 V 19 panels
25 C (77 F STC) 47.94 V 12 panels 575.3 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M612B380?

Closest cross-brand CEC competitors to Auxin Solar AXN6M612B380 matched near 380.0 W STC and 47.94 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
CSI Solar Co Ltd CS3U-385MB-AG
CSI Solar Co Ltd
385.0 W +5.0 W 48.0 V 19.85% 93.9%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.06% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M612B380?

Evaluate Auxin Solar AXN6M612B380 (380.0 W STC, 47.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M612B380 reaches 53.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 466 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (466 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M612B380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6M612B380 8 kW Residential Fit

Needs 22 modules (466 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 353.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6M612B380 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN6M612B380 panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN6M612B380 cold Voc rises from 47.94 V to 52.59 V (beta_Voc -0.277%/C), capping a 600 V string at 11 panels (578.5 V).

How much roof area does an 8 kW array of Auxin Solar AXN6M612B380 need?

An 8 kW DC system uses 22 Auxin Solar AXN6M612B380 modules (8,360 W STC / 7,784 W PTC), covering roughly 466 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does Auxin Solar AXN6M612B380 compare against CSI Solar Co Ltd CS3U-380PB-AG?

Auxin Solar AXN6M612B380 outputs 380.0 W STC (47.94 V Voc, rank #11,043 of 21,677), while CSI Solar Co Ltd CS3U-380PB-AG delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.