Auxin Solar AXN6M612B380 is a 380.0 W STC (353.8 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.3% efficiency, 47.94 V Voc at 25 C, and 52.59 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 353.8 W
- Voc @ 25C
- 47.94 V
- Efficiency
- 19.3%
How Does Auxin Solar AXN6M612B380 Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXN6M612B380 (380.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.
Ranking #11,043 across 21,677 CEC solar panels (below all-CEC median; higher than 47.6% of peers), Auxin Solar AXN6M612B380 operates as a compact residential or specialty off-grid module sitting 30.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.94 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677), 22 panels occupy 466 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Auxin Solar AXN6M612B380 Fall Across Listed CEC Models?
Plots Auxin Solar AXN6M612B380 at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXN6M612B380?
Benchmarks Auxin Solar AXN6M612B380 on STC wattage, thermal PTC/STC retention, and 19.3 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXN6M612B380?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN6M612B380 by Auxin Solar.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.3% Aperture Efficiency
Power density 193.0 W/m2 (0.61 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.59 V at -10 C (578.5 V string) and 53.92 V at -20 C (11 max).
22 Panels = 8,360 W STC
Occupies 43.3 m2 (466 sq ft) producing 7,784 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.94 * (1 + (-0.277/100) * (-10 - 25)) = 52.59 V | OCPD = 1.56 * 10.35 = 16.15 A
Inputs from CEC Modules.csv for Auxin Solar AXN6M612B380: Voc=47.94 V, beta_Voc=-0.277%/C, Isc=10.35 A, STC=380.0 W, Area=1.969 m2.
Result: 11 panels max on 600 V (578.5 V); 22 panels for 8 kW (466 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN6M612B380?
Laboratory test ratings recorded for Auxin Solar AXN6M612B380 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 353.8 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.94 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.94 V / 9.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.3% (1.969 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Auxin Solar AXN6M612B380 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (466 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN6M612B380.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 339 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 466 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 572 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXN6M612B380 under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612B375 | 375.0 W | 349.0 W | 47.85 V | 38.86 V | 19.05% |
| Auxin Solar AXN6M612B380 | 380.0 W | 353.8 W | 47.94 V | 38.94 V | 19.3% |
How Many Auxin Solar AXN6M612B380 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXN6M612B380 (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.92 V | 11 panels | 593.1 V | 18 panels |
| -10 C (14 F) | 52.59 V | 11 panels | 578.5 V | 19 panels |
| 0 C (32 F) | 51.26 V | 11 panels | 563.9 V | 19 panels |
| 25 C (77 F STC) | 47.94 V | 12 panels | 575.3 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6M612B380?
Closest cross-brand CEC competitors to Auxin Solar AXN6M612B380 matched near 380.0 W STC and 47.94 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-380PB-AG CSI Solar Co Ltd |
380.0 W | Tie (0 W) | 47.8 V | 19.29% | 93.5% |
| CSI Solar Co Ltd CS3U-385MB-AG CSI Solar Co Ltd |
385.0 W | +5.0 W | 48.0 V | 19.85% | 93.9% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF Boviet Solar Technology Co Ltd |
385.0 W | +5.0 W | 48.45 V | 19.15% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG Boviet Solar Technology Co Ltd |
385.0 W | +5.0 W | 48.45 V | 19.06% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6M612B380?
Evaluate Auxin Solar AXN6M612B380 (380.0 W STC, 47.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6M612B380 reaches 53.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 466 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (466 sq ft).
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6M612B380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN6M612B380 8 kW Residential Fit
Needs 22 modules (466 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 353.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN6M612B380 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Auxin Solar AXN6M612B380 panels fit on a 600 V winter solar string?
At -10 C (14 F), Auxin Solar AXN6M612B380 cold Voc rises from 47.94 V to 52.59 V (beta_Voc -0.277%/C), capping a 600 V string at 11 panels (578.5 V).
How much roof area does an 8 kW array of Auxin Solar AXN6M612B380 need?
An 8 kW DC system uses 22 Auxin Solar AXN6M612B380 modules (8,360 W STC / 7,784 W PTC), covering roughly 466 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Auxin Solar AXN6M612B380 compare against CSI Solar Co Ltd CS3U-380PB-AG?
Auxin Solar AXN6M612B380 outputs 380.0 W STC (47.94 V Voc, rank #11,043 of 21,677), while CSI Solar Co Ltd CS3U-380PB-AG delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)