Mundra Solar PV Limited (Adani) ASB-M10-144-580 — CEC Solar Module Specifications

Manufacturer: Mundra Solar PV Limited (Adani) Registry: CEC Verified Engineering Specification

Mundra Solar PV Limited (Adani) ASB-M10-144-580 is a 580.0 W STC (547.2 W PTC) Mono-c-Si solar module ranking #1,885 of 21,677 CEC listings (top 9.4%; higher than 90.6% of peers). It delivers 22.57% efficiency, 51.4 V Voc at 25 C, and 55.7 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
580.0 W
PTC Wattage
547.2 W
Voc @ 25C
51.4 V
Efficiency
22.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mundra Solar PV Limited (Adani) ASB-M10-144-580 Compare Against Peer CEC Listings?

How Mundra Solar PV Limited (Adani) Mundra Solar PV Limited (Adani) ASB-M10-144-580 handles rooftop heat (547.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Mundra Solar PV Limited (Adani) ASB-M10-144-580 exhibits 14.24 A short-circuit current, requiring a 22.21 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,885 of 21,677 (170.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.0 m2 for an 8 kW system (18 panels for 10 kW). Higher 51.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Mundra Solar PV Limited (Adani) ASB-M10-144-580 Fall Across Listed CEC Models?

Where Mundra Solar PV Limited (Adani) ASB-M10-144-580 (580.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mundra Solar PV Limited (Adani) ASB-M10-144-580 (580.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMundra Solar PV Li: 580.0 W

What Dataset Percentiles Define Mundra Solar PV Limited (Adani) ASB-M10-144-580?

Percentile placement of Mundra Solar PV Limited (Adani) ASB-M10-144-580 across power density (225.7 W/m2), thermal retention, and nameplate STC wattage.

Mundra Solar PV Limited (Adani) ASB-M10-144-580 Engineering BenchmarksPercentile comparison of Mundra Solar PV Limited (Adani) ASB-M10-144-580 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage580.0 WPTC/STC Retention94.3%Module Efficiency22.57%

What Do the Dataset Ranks Show for Mundra Solar PV Limited (Adani) ASB-M10-144-580?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mundra Solar PV Limited (Adani) ASB-M10-144-580 specifications.

Rank #1,885 / 21,677

Top 9.4% STC Output

580.0 W STC (+195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,869

22.57% Aperture Efficiency

Power density 225.7 W/m2 (2.66 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.7 V at -10 C (557.0 V string) and 56.93 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,120 W STC

Occupies 36.0 m2 (387 sq ft) producing 7,661 W PTC; NEC 690.8 OCPD floor is 22.21 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.4 * (1 + (-0.239/100) * (-10 - 25)) = 55.7 V | OCPD = 1.56 * 14.24 = 22.21 A

Inputs from CEC Modules.csv for Mundra Solar PV Limited (Adani) ASB-M10-144-580: Voc=51.4 V, beta_Voc=-0.239%/C, Isc=14.24 A, STC=580.0 W, Area=2.57 m2.

Result: 10 panels max on 600 V (557.0 V); 14 panels for 8 kW (387 sq ft).

What Are the Published CEC Specifications for Mundra Solar PV Limited (Adani) ASB-M10-144-580?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mundra Solar PV Limited (Adani) ASB-M10-144-580.

Official California Energy Commission (NREL SAM) test parameters for Mundra Solar PV Limited (Adani) ASB-M10-144-580.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 580.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 547.2 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.2 V / 13.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.239 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.57% (2.57 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Mundra Solar PV Limited (Adani) ASB-M10-144-580 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mundra Solar PV Limited (Adani) ASB-M10-144-580 (580.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.38 kW 304 sq ft $1,597 $2,700
8 kW Class 14 8.12 kW 387 sq ft $2,032 $3,437
10 kW Class 18 10.44 kW 498 sq ft $2,613 $4,418

Which Sibling Wattage & Trim Variants Belong to This Mundra Solar PV Limited (Adani) Series?

All closely matched Mundra Solar PV Limited (Adani) wattages and cosmetic trims sharing the Mundra Solar PV Limited (Adani) ASB-M10-144-580 architecture.

Sibling CEC listings grouped into the Mundra Solar PV Limited (Adani) ASB-M10-144-580 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mundra Solar PV Limited (Adani) ASB-M10-144-575 575.0 W 542.4 W 51.2 V 43.0 V 22.37%
Mundra Solar PV Limited (Adani) ASB-M10-144-580 580.0 W 547.2 W 51.4 V 43.2 V 22.57%

How Many Mundra Solar PV Limited (Adani) ASB-M10-144-580 Modules Fit in a Cold-Weather String?

Maximum series module counts for Mundra Solar PV Limited (Adani) ASB-M10-144-580 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=51.4V and beta_Voc=-0.239%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.93 V 10 panels 569.3 V 17 panels
-10 C (14 F) 55.7 V 10 panels 557.0 V 17 panels
0 C (32 F) 54.47 V 11 panels 599.2 V 18 panels
25 C (77 F STC) 51.4 V 11 panels 565.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Mundra Solar PV Limited (Adani) ASB-M10-144-580?

Alternative CEC solar modules from competing brands near Mundra Solar PV Limited (Adani) ASB-M10-144-580 (580.0 W), including EMMVEE Photovoltaic Power Private Limited E580HCBT144-T.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E580HCBT144-T
EMMVEE Photovoltaic Power Private Limited
580.0 W Tie (0 W) 51.47 V 22.66% 94.6%
Gautam Solar Pvt Ltd G2G1740-HAD
Gautam Solar Pvt Ltd
580.0 W Tie (0 W) 51.04 V 22.59% 95.1%
Gautam Solar Pvt Ltd G2X1740N-UHAD
Gautam Solar Pvt Ltd
580.0 W Tie (0 W) 51.04 V 22.57% 94.9%
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
585.0 W +5.0 W 51.5 V 22.85% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mundra Solar PV Limited (Adani) ASB-M10-144-580?

Evaluate Mundra Solar PV Limited (Adani) ASB-M10-144-580 (580.0 W STC, 51.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar PV Limited (Adani) ASB-M10-144-580 reaches 56.93 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 387 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Mundra Solar PV Limited (Adani) ASB-M10-144-580 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mundra Solar PV Limited (Adani) ASB-M10-144-580 8 kW Residential Fit

Needs 14 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E580HCBT144-T.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 547.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mundra Solar PV Limited (Adani) ASB-M10-144-580 by Mundra Solar PV Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Mundra Solar PV Limited (Adani) ASB-M10-144-580 PTC wattage (547.2 W) lower than STC (580.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 547.2 W PTC (94.3% retention) across Mundra Solar PV Limited (Adani) ASB-M10-144-580's 2.57 m2 aperture.

Who should skip Mundra Solar PV Limited (Adani) ASB-M10-144-580 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Mundra Solar PV Limited (Adani) ASB-M10-144-580 panels (387 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E580HCBT144-T.

What is the 1,000 V commercial string limit for Mundra Solar PV Limited (Adani) ASB-M10-144-580?

On 1,000 V commercial inverters at -10 C (55.7 V cold Voc), Mundra Solar PV Limited (Adani) ASB-M10-144-580 fits up to 17 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.