EMMVEE Photovoltaic Power Private Limited E560HCBG144-T is a 560.0 W STC (522.9 W PTC) Mono-c-Si solar module ranking #2,404 of 21,677 CEC listings (top 11.8%; higher than 88.2% of peers). It delivers 21.88% efficiency, 50.67 V Voc at 25 C, and 55.0 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 560.0 W
- PTC Wattage
- 522.9 W
- Voc @ 25C
- 50.67 V
- Efficiency
- 21.88%
How Does EMMVEE Photovoltaic Power Private Limited E560HCBG144-T Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T (Mono-c-Si) residential solar systems.
Homeowners evaluating EMMVEE Photovoltaic Power Private Limited E560HCBG144-T need 11 panels for 6 kW or 15 panels (413 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.244%/C) pushes open-circuit voltage to 55.0 V at 14 F and 56.23 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does EMMVEE Photovoltaic Power Private Limited E560HCBG144-T Fall Across Listed CEC Models?
Comparison of EMMVEE Photovoltaic Power Private Limited E560HCBG144-T (560.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Relative ranking of EMMVEE Photovoltaic Power Private Limited E560HCBG144-T across nameplate watts, 93.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Summary of EMMVEE Photovoltaic Power Private Limited E560HCBG144-T output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 11.8% STC Output
560.0 W STC (+175.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.88% Aperture Efficiency
Power density 218.8 W/m2 (1.97 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.0 V at -10 C (550.0 V string) and 56.23 V at -20 C (10 max).
15 Panels = 8,400 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,844 W PTC; NEC 690.8 OCPD floor is 22.04 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.67 * (1 + (-0.244/100) * (-10 - 25)) = 55.0 V | OCPD = 1.56 * 14.13 = 22.04 A
Inputs from CEC Modules.csv for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T: Voc=50.67 V, beta_Voc=-0.244%/C, Isc=14.13 A, STC=560.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (550.0 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Complete CEC test sheet for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T including Isc (14.13 A), Voc (50.67 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 560.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 522.9 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.95 V / 13.35 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.244 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.88% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 144 cells (Mono-c-Si) | Bifacial glass-glass |
How Many EMMVEE Photovoltaic Power Private Limited E560HCBG144-T Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using EMMVEE Photovoltaic Power Private Limited E560HCBG144-T.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.16 kW | 303 sq ft | $1,542 | $2,607 |
| 8 kW Class | 15 | 8.4 kW | 413 sq ft | $2,102 | $3,555 |
| 10 kW Class | 18 | 10.08 kW | 496 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This EMMVEE Photovoltaic Power Private Limited Series?
Related EMMVEE Photovoltaic Power Private Limited power steps and black/silver trims consolidated into this EMMVEE Photovoltaic Power Private Limited E560HCBG144-T series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E550HCBG144-T | 550.0 W | 513.3 W | 50.27 V | 41.58 V | 21.48% |
| EMMVEE Photovoltaic Power Private Limited E555HCBG144-T | 555.0 W | 518.1 W | 50.47 V | 41.77 V | 21.68% |
| EMMVEE Photovoltaic Power Private Limited E560HCBG144-T | 560.0 W | 522.9 W | 50.67 V | 41.95 V | 21.88% |
| EMMVEE Photovoltaic Power Private Limited E565HCBG144-T | 565.0 W | 527.7 W | 50.87 V | 42.14 V | 22.07% |
| EMMVEE Photovoltaic Power Private Limited E570HCBG144-T | 570.0 W | 532.5 W | 51.07 V | 42.29 V | 22.27% |
How Many EMMVEE Photovoltaic Power Private Limited E560HCBG144-T Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T (50.67 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.23 V | 10 panels | 562.3 V | 17 panels |
| -10 C (14 F) | 55.0 V | 10 panels | 550.0 V | 18 panels |
| 0 C (32 F) | 53.76 V | 11 panels | 591.4 V | 18 panels |
| 25 C (77 F STC) | 50.67 V | 11 panels | 557.4 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Four comparable CEC modules such as Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560 (560.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560 Chint New Energy Technology Co Ltd |
560.0 W | Tie (0 W) | 50.5 V | 21.71% | 94.6% |
| Gautam Solar Pvt Ltd G2G1680-HAD Gautam Solar Pvt Ltd |
560.0 W | Tie (0 W) | 50.44 V | 21.81% | 95.1% |
| Gautam Solar Pvt Ltd G2X1680N-UHAD Gautam Solar Pvt Ltd |
560.0 W | Tie (0 W) | 50.44 V | 21.79% | 94.8% |
| Bila Solar Inc AA560US-6x24GG Bila Solar Inc |
560.0 W | Tie (0 W) | 50.2 V | 22.31% | 92.9% |
What Are the Design Limits and Best-Fit Uses for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
Evaluate EMMVEE Photovoltaic Power Private Limited E560HCBG144-T (560.0 W STC, 50.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), EMMVEE Photovoltaic Power Private Limited E560HCBG144-T reaches 56.23 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of EMMVEE Photovoltaic Power Private Limited E560HCBG144-T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
EMMVEE Photovoltaic Power Private Limited E560HCBG144-T 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 522.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T by EMMVEE Photovoltaic Power Private Limited grounded in CEC test data and NEC 690.7/690.8 limits.
Why is EMMVEE Photovoltaic Power Private Limited E560HCBG144-T PTC wattage (522.9 W) lower than STC (560.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 522.9 W PTC (93.4% retention) across EMMVEE Photovoltaic Power Private Limited E560HCBG144-T's 2.56 m2 aperture.
Who should skip EMMVEE Photovoltaic Power Private Limited E560HCBG144-T on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 EMMVEE Photovoltaic Power Private Limited E560HCBG144-T panels (413 sq ft) leave unusable roof gaps vs. Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560.
What is the 1,000 V commercial string limit for EMMVEE Photovoltaic Power Private Limited E560HCBG144-T?
On 1,000 V commercial inverters at -10 C (55.0 V cold Voc), EMMVEE Photovoltaic Power Private Limited E560HCBG144-T fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)