GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 is a 535.0 W STC (502.5 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.39 V Voc at 25 C, and 53.61 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 502.5 W
- Voc @ 25C
- 49.39 V
- Efficiency
- 20.74%
How Does GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 Compare Against Peer CEC Listings?
How GOLDI SUN PRIVATE LIMITED GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 handles rooftop heat (502.5 W PTC), 8 kW sizing, and cold winter string voltage.
GOLDI SUN PRIVATE LIMITED builds the GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM72M-HC-535 (535.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 49.39 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 20.92 A overcurrent floor served by a 25 A breaker.
Where Does GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 Fall Across Listed CEC Models?
Where GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Percentile placement of GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 across power density (207.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Four critical engineering numbers homeowners and solar installers check first when reviewing GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 specifications.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.61 V at -10 C (589.7 V string) and 54.81 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,538 W PTC; NEC 690.8 OCPD floor is 20.92 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.39 * (1 + (-0.244/100) * (-10 - 25)) = 53.61 V | OCPD = 1.56 * 13.41 = 20.92 A
Inputs from CEC Modules.csv for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535: Voc=49.39 V, beta_Voc=-0.244%/C, Isc=13.41 A, STC=535.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (589.7 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 502.5 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.39 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.64 V / 12.26 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.244 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 (535.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 333 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 417 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 528 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This GOLDI SUN PRIVATE LIMITED Series?
All closely matched GOLDI SUN PRIVATE LIMITED wattages and cosmetic trims sharing the GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GOLDI SUN PRIVATE LIMITED GS10-M144-BF-525 | 525.0 W | 492.9 W | 49.25 V | 43.33 V | 20.35% |
| GOLDI SUN PRIVATE LIMITED GS10-M144-BF-530 | 530.0 W | 497.7 W | 49.32 V | 43.56 V | 20.54% |
| GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 | 535.0 W | 502.5 W | 49.39 V | 43.64 V | 20.74% |
| GOLDI SUN PRIVATE LIMITED GS10-M144-BF-540 | 540.0 W | 507.3 W | 49.46 V | 43.88 V | 20.93% |
How Many GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 Modules Fit in a Cold-Weather String?
Maximum series module counts for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.81 V | 10 panels | 548.1 V | 18 panels |
| -10 C (14 F) | 53.61 V | 11 panels | 589.7 V | 18 panels |
| 0 C (32 F) | 52.4 V | 11 panels | 576.4 V | 19 panels |
| 25 C (77 F STC) | 49.39 V | 12 panels | 592.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Alternative CEC solar modules from competing brands near GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 (535.0 W), including Elin Energy (Sirius PV) ELNSM72M-HC-535.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM72M-HC-535 Elin Energy (Sirius PV) |
535.0 W | Tie (0 W) | 49.4 V | 20.9% | 94.3% |
| BYD Company Limited BYD535MLTK-36 BYD Company Limited |
535.0 W | Tie (0 W) | 49.42 V | 20.74% | 92.9% |
| Allesun Industries Inc AS-535-72IIMB Allesun Industries Inc |
535.0 W | Tie (0 W) | 49.35 V | 20.9% | 94.1% |
| GermanSolar USA Inc GSM-535W-HC GermanSolar USA Inc |
535.0 W | Tie (0 W) | 49.35 V | 22.48% | 94.6% |
What Are the Design Limits and Best-Fit Uses for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Evaluate GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 (535.0 W STC, 49.39 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 reaches 54.81 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM72M-HC-535.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 502.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 by GOLDI SUN PRIVATE LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535?
Multiplying GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535's 13.41 A short-circuit current by 1.56 equals 20.92 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.61 V cold Voc at 14 F and handles 13.41 A Isc; string inverters cap GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 at 11 panels on 600 V.
Is GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)