Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 144HC-540 M10 Bifacial is a 540.0 W STC (508.9 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.51% efficiency, 50.22 V Voc at 25 C, and 54.67 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
508.9 W
Voc @ 25C
50.22 V
Efficiency
21.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 144HC-540 M10 Bifacial Compare Against Peer CEC Listings?

Engineering position of Heliene 144HC-540 M10 Bifacial (540.0 W STC) vs. Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Heliene 144HC-540 M10 Bifacial pairs strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677) with 50.22 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,634 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF offers a 540.0 W alternative.

Where Does Heliene 144HC-540 M10 Bifacial Fall Across Listed CEC Models?

Plots Heliene 144HC-540 M10 Bifacial at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 144HC-540 M10 Bifacial (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 144HC-540 : 540.0 W

What Dataset Percentiles Define Heliene 144HC-540 M10 Bifacial?

Benchmarks Heliene 144HC-540 M10 Bifacial on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.

Heliene 144HC-540 M10 Bifacial Engineering BenchmarksPercentile comparison of Heliene 144HC-540 M10 Bifacial wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention94.2%Module Efficiency21.51%

What Do the Dataset Ranks Show for Heliene 144HC-540 M10 Bifacial?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 144HC-540 M10 Bifacial by Heliene.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,356

21.51% Aperture Efficiency

Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.67 V at -10 C (546.7 V string) and 55.94 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.22 * (1 + (-0.253/100) * (-10 - 25)) = 54.67 V | OCPD = 1.56 * 13.5 = 21.06 A

Inputs from CEC Modules.csv for Heliene 144HC-540 M10 Bifacial: Voc=50.22 V, beta_Voc=-0.253%/C, Isc=13.5 A, STC=540.0 W, Area=2.51 m2.

Result: 10 panels max on 600 V (546.7 V); 15 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for Heliene 144HC-540 M10 Bifacial?

Laboratory test ratings recorded for Heliene 144HC-540 M10 Bifacial (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 144HC-540 M10 Bifacial.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 508.9 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.22 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.32 V / 12.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.253 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.51% (2.51 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Heliene 144HC-540 M10 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 144HC-540 M10 Bifacial.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 324 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 405 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 513 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Sibling wattage bins and frame colors grouped with Heliene 144HC-540 M10 Bifacial under Heliene to prevent duplicate spec pages.

Sibling CEC listings grouped into the Heliene 144HC-540 M10 Bifacial wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 144HC-530 M10 Bifacial 530.0 W 499.2 W 49.72 V 41.94 V 21.12%
Heliene 144HC-540 M10 Bifacial 540.0 W 508.9 W 50.22 V 42.32 V 21.51%

How Many Heliene 144HC-540 M10 Bifacial Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 144HC-540 M10 Bifacial (beta_Voc -0.253%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=50.22V and beta_Voc=-0.253%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.94 V 10 panels 559.4 V 17 panels
-10 C (14 F) 54.67 V 10 panels 546.7 V 18 panels
0 C (32 F) 53.4 V 11 panels 587.4 V 18 panels
25 C (77 F STC) 50.22 V 11 panels 552.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-540 M10 Bifacial?

Closest cross-brand CEC competitors to Heliene 144HC-540 M10 Bifacial matched near 540.0 W STC and 50.22 V Voc, led by Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF
Boviet Solar Technology Co Ltd
540.0 W Tie (0 W) 49.89 V 20.77% 94.1%
ASTORIOS Holding Inc ASTR144BDG-540W-US
ASTORIOS Holding Inc
540.0 W Tie (0 W) 49.8 V 20.93% 93.6%
Energy America LLC EA-ZLK7-SHDB144-540/M
Energy America LLC
540.0 W Tie (0 W) 49.8 V 20.93% 93.6%
Hansol Technics Co Ltd HA540XD-GNEA0
Hansol Technics Co Ltd
540.0 W Tie (0 W) 49.8 V 21.09% 94.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 144HC-540 M10 Bifacial?

Evaluate Heliene 144HC-540 M10 Bifacial (540.0 W STC, 50.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-540 M10 Bifacial reaches 55.94 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 405 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Heliene 144HC-540 M10 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 144HC-540 M10 Bifacial 8 kW Residential Fit

Needs 15 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 508.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 144HC-540 M10 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Heliene 144HC-540 M10 Bifacial?

Multiplying Heliene 144HC-540 M10 Bifacial's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Heliene 144HC-540 M10 Bifacial pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.67 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap Heliene 144HC-540 M10 Bifacial at 10 panels on 600 V.

Is Heliene 144HC-540 M10 Bifacial eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 144HC-540 M10 Bifacial rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.