Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA540XD-GNEA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA540XD-GNEA0 is a 540.0 W STC (509.8 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.8 V Voc at 25 C, and 54.23 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
509.8 W
Voc @ 25C
49.8 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA540XD-GNEA0 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA540XD-GNEA0 (Mono-c-Si) residential solar systems.

Hansol Technics Co Ltd HA540XD-GNEA0 delivers 210.9 W/m2 (1.18 percentage points above 19.91% CEC median) and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 55.49 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with ASTORIOS Holding Inc ASTR144BDG-540W-US (540.0 W).

Where Does Hansol Technics Co Ltd HA540XD-GNEA0 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HA540XD-GNEA0 (540.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA540XD-GNEA0 (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 540.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA540XD-GNEA0?

Relative ranking of Hansol Technics Co Ltd HA540XD-GNEA0 across nameplate watts, 94.4% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HA540XD-GNEA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA540XD-GNEA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention94.4%Module Efficiency21.09%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA540XD-GNEA0?

Summary of Hansol Technics Co Ltd HA540XD-GNEA0 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.23 V at -10 C (596.5 V string) and 55.49 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,647 W PTC; NEC 690.8 OCPD floor is 21.48 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.254/100) * (-10 - 25)) = 54.23 V | OCPD = 1.56 * 13.77 = 21.48 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA540XD-GNEA0: Voc=49.8 V, beta_Voc=-0.254%/C, Isc=13.77 A, STC=540.0 W, Area=2.56 m2.

Result: 11 panels max on 600 V (596.5 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA540XD-GNEA0?

Complete CEC test sheet for Hansol Technics Co Ltd HA540XD-GNEA0 including Isc (13.77 A), Voc (49.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA540XD-GNEA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 509.8 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.5 V / 13.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.254 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Hansol Technics Co Ltd HA540XD-GNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA540XD-GNEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 331 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 413 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 524 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HA540XD-GNEA0 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HA540XD-GNEA0 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HA530XD-GNEA0 530.0 W 500.1 W 49.4 V 41.1 V 20.7%
Hansol Technics Co Ltd HA535XD-GNEA0 535.0 W 505.0 W 49.6 V 41.3 V 20.9%
Hansol Technics Co Ltd HA540XD-GNEA0 540.0 W 509.8 W 49.8 V 41.5 V 21.09%
Hansol Technics Co Ltd HA545XD-GNEA0 545.0 W 514.6 W 51.8 V 41.7 V 21.29%

How Many Hansol Technics Co Ltd HA540XD-GNEA0 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA540XD-GNEA0 (49.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.8V and beta_Voc=-0.254%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.49 V 10 panels 554.9 V 18 panels
-10 C (14 F) 54.23 V 11 panels 596.5 V 18 panels
0 C (32 F) 52.96 V 11 panels 582.6 V 18 panels
25 C (77 F STC) 49.8 V 12 panels 597.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA540XD-GNEA0?

Four comparable CEC modules such as ASTORIOS Holding Inc ASTR144BDG-540W-US (540.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR144BDG-540W-US
ASTORIOS Holding Inc
540.0 W Tie (0 W) 49.8 V 20.93% 93.6%
Energy America LLC EA-ZLK7-SHDB144-540/M
Energy America LLC
540.0 W Tie (0 W) 49.8 V 20.93% 93.6%
Hounen Solar America Inc HNM7-SHDB144-540/M
Hounen Solar America Inc
540.0 W Tie (0 W) 49.8 V 20.93% 93.6%
Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF
Boviet Solar Technology Co Ltd
540.0 W Tie (0 W) 49.89 V 20.77% 94.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA540XD-GNEA0?

Evaluate Hansol Technics Co Ltd HA540XD-GNEA0 (540.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA540XD-GNEA0 reaches 55.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA540XD-GNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA540XD-GNEA0 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ASTORIOS Holding Inc ASTR144BDG-540W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 509.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA540XD-GNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HA540XD-GNEA0 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HA540XD-GNEA0 cold Voc rises from 49.8 V to 54.23 V (beta_Voc -0.254%/C), capping a 600 V string at 11 panels (596.5 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HA540XD-GNEA0 need?

An 8 kW DC system uses 15 Hansol Technics Co Ltd HA540XD-GNEA0 modules (8,100 W STC / 7,647 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HA540XD-GNEA0 compare against ASTORIOS Holding Inc ASTR144BDG-540W-US?

Hansol Technics Co Ltd HA540XD-GNEA0 outputs 540.0 W STC (49.8 V Voc, rank #3,265 of 21,677), while ASTORIOS Holding Inc ASTR144BDG-540W-US delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.