Hansol Technics Co Ltd HA540XD-GNEA0 is a 540.0 W STC (509.8 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.8 V Voc at 25 C, and 54.23 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 509.8 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 21.09%
How Does Hansol Technics Co Ltd HA540XD-GNEA0 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA540XD-GNEA0 (Mono-c-Si) residential solar systems.
Hansol Technics Co Ltd HA540XD-GNEA0 delivers 210.9 W/m2 (1.18 percentage points above 19.91% CEC median) and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 55.49 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with ASTORIOS Holding Inc ASTR144BDG-540W-US (540.0 W).
Where Does Hansol Technics Co Ltd HA540XD-GNEA0 Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HA540XD-GNEA0 (540.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HA540XD-GNEA0?
Relative ranking of Hansol Technics Co Ltd HA540XD-GNEA0 across nameplate watts, 94.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA540XD-GNEA0?
Summary of Hansol Technics Co Ltd HA540XD-GNEA0 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.09% Aperture Efficiency
Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.23 V at -10 C (596.5 V string) and 55.49 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,647 W PTC; NEC 690.8 OCPD floor is 21.48 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.254/100) * (-10 - 25)) = 54.23 V | OCPD = 1.56 * 13.77 = 21.48 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA540XD-GNEA0: Voc=49.8 V, beta_Voc=-0.254%/C, Isc=13.77 A, STC=540.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (596.5 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA540XD-GNEA0?
Complete CEC test sheet for Hansol Technics Co Ltd HA540XD-GNEA0 including Isc (13.77 A), Voc (49.8 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 509.8 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 13.02 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.09% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hansol Technics Co Ltd HA540XD-GNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA540XD-GNEA0.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 331 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 413 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 524 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HA540XD-GNEA0 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA530XD-GNEA0 | 530.0 W | 500.1 W | 49.4 V | 41.1 V | 20.7% |
| Hansol Technics Co Ltd HA535XD-GNEA0 | 535.0 W | 505.0 W | 49.6 V | 41.3 V | 20.9% |
| Hansol Technics Co Ltd HA540XD-GNEA0 | 540.0 W | 509.8 W | 49.8 V | 41.5 V | 21.09% |
| Hansol Technics Co Ltd HA545XD-GNEA0 | 545.0 W | 514.6 W | 51.8 V | 41.7 V | 21.29% |
How Many Hansol Technics Co Ltd HA540XD-GNEA0 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA540XD-GNEA0 (49.8 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.49 V | 10 panels | 554.9 V | 18 panels |
| -10 C (14 F) | 54.23 V | 11 panels | 596.5 V | 18 panels |
| 0 C (32 F) | 52.96 V | 11 panels | 582.6 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA540XD-GNEA0?
Four comparable CEC modules such as ASTORIOS Holding Inc ASTR144BDG-540W-US (540.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR144BDG-540W-US ASTORIOS Holding Inc |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Energy America LLC EA-ZLK7-SHDB144-540/M Energy America LLC |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Hounen Solar America Inc HNM7-SHDB144-540/M Hounen Solar America Inc |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF Boviet Solar Technology Co Ltd |
540.0 W | Tie (0 W) | 49.89 V | 20.77% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA540XD-GNEA0?
Evaluate Hansol Technics Co Ltd HA540XD-GNEA0 (540.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA540XD-GNEA0 reaches 55.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA540XD-GNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA540XD-GNEA0 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ASTORIOS Holding Inc ASTR144BDG-540W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 509.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA540XD-GNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HA540XD-GNEA0 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HA540XD-GNEA0 cold Voc rises from 49.8 V to 54.23 V (beta_Voc -0.254%/C), capping a 600 V string at 11 panels (596.5 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HA540XD-GNEA0 need?
An 8 kW DC system uses 15 Hansol Technics Co Ltd HA540XD-GNEA0 modules (8,100 W STC / 7,647 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HA540XD-GNEA0 compare against ASTORIOS Holding Inc ASTR144BDG-540W-US?
Hansol Technics Co Ltd HA540XD-GNEA0 outputs 540.0 W STC (49.8 V Voc, rank #3,265 of 21,677), while ASTORIOS Holding Inc ASTR144BDG-540W-US delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)