Hounen Solar America Inc HNM7-SHDB144-540/M is a 540.0 W STC (505.4 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 20.93% efficiency, 49.8 V Voc at 25 C, and 54.38 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 505.4 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 20.93%
How Does Hounen Solar America Inc HNM7-SHDB144-540/M Compare Against Peer CEC Listings?
Solar engineering breakdown for Hounen Solar America Inc HNM7-SHDB144-540/M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hounen Solar America Inc and peers, Hounen Solar America Inc HNM7-SHDB144-540/M stands 130.0 W above the 410.0 W Mono-c-Si median and strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,622-$2,568/yr in baseline US bill offset. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Hounen Solar America Inc HNM7-SHDB144-540/M Fall Across Listed CEC Models?
Distribution marker showing Hounen Solar America Inc HNM7-SHDB144-540/M (540.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hounen Solar America Inc HNM7-SHDB144-540/M?
Dataset percentiles tracking Hounen Solar America Inc HNM7-SHDB144-540/M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hounen Solar America Inc HNM7-SHDB144-540/M?
Benchmark highlights for Hounen Solar America Inc HNM7-SHDB144-540/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.93% Aperture Efficiency
Power density 209.3 W/m2 (1.02 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.38 V at -10 C (598.2 V string) and 55.69 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,581 W PTC; NEC 690.8 OCPD floor is 21.48 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.263/100) * (-10 - 25)) = 54.38 V | OCPD = 1.56 * 13.77 = 21.48 A
Inputs from CEC Modules.csv for Hounen Solar America Inc HNM7-SHDB144-540/M: Voc=49.8 V, beta_Voc=-0.263%/C, Isc=13.77 A, STC=540.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (598.2 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Hounen Solar America Inc HNM7-SHDB144-540/M?
Official CEC datasheet figures for Hounen Solar America Inc HNM7-SHDB144-540/M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 505.4 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 13.02 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.93% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hounen Solar America Inc HNM7-SHDB144-540/M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hounen Solar America Inc HNM7-SHDB144-540/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 333 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 417 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 528 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Hounen Solar America Inc Series?
Consolidated Hounen Solar America Inc wattage variants sharing the Hounen Solar America Inc HNM7-SHDB144-540/M mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hounen Solar America Inc HNM7-SHDB144-530/M | 530.0 W | 495.8 W | 49.4 V | 41.1 V | 20.54% |
| Hounen Solar America Inc HNM7-SHDB144-535/M | 535.0 W | 500.6 W | 49.6 V | 41.3 V | 20.74% |
| Hounen Solar America Inc HNM7-SHDB144-540/M | 540.0 W | 505.4 W | 49.8 V | 41.5 V | 20.93% |
| Hounen Solar America Inc HNM7-SHDB144-545/M | 545.0 W | 510.2 W | 50.0 V | 41.7 V | 21.12% |
How Many Hounen Solar America Inc HNM7-SHDB144-540/M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hounen Solar America Inc HNM7-SHDB144-540/M (54.38 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.69 V | 10 panels | 556.9 V | 17 panels |
| -10 C (14 F) | 54.38 V | 11 panels | 598.2 V | 18 panels |
| 0 C (32 F) | 53.07 V | 11 panels | 583.8 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hounen Solar America Inc HNM7-SHDB144-540/M?
Competing CEC solar panels closest to Hounen Solar America Inc HNM7-SHDB144-540/M in nameplate wattage and Voc, starting with ASTORIOS Holding Inc ASTR144BDG-540W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR144BDG-540W-US ASTORIOS Holding Inc |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Energy America LLC EA-ZLK7-SHDB144-540/M Energy America LLC |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Hansol Technics Co Ltd HA540XD-GNEA0 Hansol Technics Co Ltd |
540.0 W | Tie (0 W) | 49.8 V | 21.09% | 94.4% |
| Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF Boviet Solar Technology Co Ltd |
540.0 W | Tie (0 W) | 49.89 V | 20.77% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Hounen Solar America Inc HNM7-SHDB144-540/M?
Evaluate Hounen Solar America Inc HNM7-SHDB144-540/M (540.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hounen Solar America Inc HNM7-SHDB144-540/M reaches 55.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hounen Solar America Inc HNM7-SHDB144-540/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hounen Solar America Inc HNM7-SHDB144-540/M 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ASTORIOS Holding Inc ASTR144BDG-540W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 505.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hounen Solar America Inc HNM7-SHDB144-540/M by Hounen Solar America Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hounen Solar America Inc HNM7-SHDB144-540/M?
Multiplying Hounen Solar America Inc HNM7-SHDB144-540/M's 13.77 A short-circuit current by 1.56 equals 21.48 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hounen Solar America Inc HNM7-SHDB144-540/M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.38 V cold Voc at 14 F and handles 13.77 A Isc; string inverters cap Hounen Solar America Inc HNM7-SHDB144-540/M at 11 panels on 600 V.
Is Hounen Solar America Inc HNM7-SHDB144-540/M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hounen Solar America Inc HNM7-SHDB144-540/M rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)