Manufacturer: Hounen Solar America Inc Registry: CEC Verified Engineering Specification

Hounen Solar America Inc HNM7-SHDB108-410/M is a 410.0 W STC (381.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.5 V Voc at 25 C, and 40.99 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
381.2 W
Voc @ 25C
37.5 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hounen Solar America Inc HNM7-SHDB108-410/M Compare Against Peer CEC Listings?

Solar engineering breakdown for Hounen Solar America Inc HNM7-SHDB108-410/M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 410.0 W STC and 381.2 W PTC, Hounen Solar America Inc HNM7-SHDB108-410/M sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer ASTORIOS Holding Inc ASTR108BDG-410W-US rates 410.0 W.

Where Does Hounen Solar America Inc HNM7-SHDB108-410/M Fall Across Listed CEC Models?

Distribution marker showing Hounen Solar America Inc HNM7-SHDB108-410/M (410.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hounen Solar America Inc HNM7-SHDB108-410/M (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHounen Solar Ameri: 410.0 W

What Dataset Percentiles Define Hounen Solar America Inc HNM7-SHDB108-410/M?

Dataset percentiles tracking Hounen Solar America Inc HNM7-SHDB108-410/M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hounen Solar America Inc HNM7-SHDB108-410/M Engineering BenchmarksPercentile comparison of Hounen Solar America Inc HNM7-SHDB108-410/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.0%Module Efficiency21.13%

What Do the Dataset Ranks Show for Hounen Solar America Inc HNM7-SHDB108-410/M?

Benchmark highlights for Hounen Solar America Inc HNM7-SHDB108-410/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.99 V at -10 C (573.9 V string) and 41.99 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.266/100) * (-10 - 25)) = 40.99 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for Hounen Solar America Inc HNM7-SHDB108-410/M: Voc=37.5 V, beta_Voc=-0.266%/C, Isc=13.86 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (573.9 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Hounen Solar America Inc HNM7-SHDB108-410/M?

Official CEC datasheet figures for Hounen Solar America Inc HNM7-SHDB108-410/M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hounen Solar America Inc HNM7-SHDB108-410/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.2 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.3 V / 13.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Hounen Solar America Inc HNM7-SHDB108-410/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hounen Solar America Inc HNM7-SHDB108-410/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Hounen Solar America Inc Series?

Consolidated Hounen Solar America Inc wattage variants sharing the Hounen Solar America Inc HNM7-SHDB108-410/M mechanical and cell layout.

Sibling CEC listings grouped into the Hounen Solar America Inc HNM7-SHDB108-410/M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hounen Solar America Inc HNM7-SHDB108-400/M 400.0 W 371.6 W 37.1 V 30.9 V 20.62%
Hounen Solar America Inc HNM7-SHDB108-405/M 405.0 W 376.4 W 37.3 V 31.1 V 20.88%
Hounen Solar America Inc HNM7-SHDB108-410/M 410.0 W 381.2 W 37.5 V 31.3 V 21.13%
Hounen Solar America Inc HNM7-SHDB108-415/M 415.0 W 386.0 W 37.7 V 31.5 V 21.39%

How Many Hounen Solar America Inc HNM7-SHDB108-410/M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hounen Solar America Inc HNM7-SHDB108-410/M (40.99 V at 14 F).

Computed from Voc=37.5V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.99 V 14 panels 587.9 V 23 panels
-10 C (14 F) 40.99 V 14 panels 573.9 V 24 panels
0 C (32 F) 39.99 V 15 panels 599.9 V 25 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hounen Solar America Inc HNM7-SHDB108-410/M?

Competing CEC solar panels closest to Hounen Solar America Inc HNM7-SHDB108-410/M in nameplate wattage and Voc, starting with ASTORIOS Holding Inc ASTR108BDG-410W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hounen Solar America Inc HNM7-SHDB108-410/M?

Evaluate Hounen Solar America Inc HNM7-SHDB108-410/M (410.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hounen Solar America Inc HNM7-SHDB108-410/M reaches 41.99 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hounen Solar America Inc HNM7-SHDB108-410/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hounen Solar America Inc HNM7-SHDB108-410/M 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hounen Solar America Inc HNM7-SHDB108-410/M by Hounen Solar America Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hounen Solar America Inc HNM7-SHDB108-410/M panels fit on a 600 V winter solar string?

At -10 C (14 F), Hounen Solar America Inc HNM7-SHDB108-410/M cold Voc rises from 37.5 V to 40.99 V (beta_Voc -0.266%/C), capping a 600 V string at 14 panels (573.9 V).

How much roof area does an 8 kW array of Hounen Solar America Inc HNM7-SHDB108-410/M need?

An 8 kW DC system uses 20 Hounen Solar America Inc HNM7-SHDB108-410/M modules (8,200 W STC / 7,624 W PTC), covering roughly 418 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does Hounen Solar America Inc HNM7-SHDB108-410/M compare against ASTORIOS Holding Inc ASTR108BDG-410W-US?

Hounen Solar America Inc HNM7-SHDB108-410/M outputs 410.0 W STC (37.5 V Voc, rank #8,539 of 21,677), while ASTORIOS Holding Inc ASTR108BDG-410W-US delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.