Hounen Solar America Inc HNM7-UHLDD144-565/N is a 565.0 W STC (530.7 W PTC) Mono-c-Si solar module ranking #2,284 of 21,677 CEC listings (top 11.1%; higher than 88.9% of peers). It delivers 21.9% efficiency, 50.9 V Voc at 25 C, and 55.35 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 565.0 W
- PTC Wattage
- 530.7 W
- Voc @ 25C
- 50.9 V
- Efficiency
- 21.9%
How Does Hounen Solar America Inc HNM7-UHLDD144-565/N Compare Against Peer CEC Listings?
Solar engineering breakdown for Hounen Solar America Inc HNM7-UHLDD144-565/N: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hounen Solar America Inc and peers, Hounen Solar America Inc HNM7-UHLDD144-565/N stands 155.0 W above the 410.0 W Mono-c-Si median and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Sizing 6 kW (11 panels) to 10 kW (18 panels) yields $1,554-$2,545/yr in baseline US bill offset. Higher 50.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Hounen Solar America Inc HNM7-UHLDD144-565/N Fall Across Listed CEC Models?
Distribution marker showing Hounen Solar America Inc HNM7-UHLDD144-565/N (565.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hounen Solar America Inc HNM7-UHLDD144-565/N?
Dataset percentiles tracking Hounen Solar America Inc HNM7-UHLDD144-565/N power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hounen Solar America Inc HNM7-UHLDD144-565/N?
Benchmark highlights for Hounen Solar America Inc HNM7-UHLDD144-565/N covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 11.1% STC Output
565.0 W STC (+180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.9% Aperture Efficiency
Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.35 V at -10 C (553.5 V string) and 56.63 V at -20 C (10 max).
15 Panels = 8,475 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,960 W PTC; NEC 690.8 OCPD floor is 22.11 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.9 * (1 + (-0.25/100) * (-10 - 25)) = 55.35 V | OCPD = 1.56 * 14.17 = 22.11 A
Inputs from CEC Modules.csv for Hounen Solar America Inc HNM7-UHLDD144-565/N: Voc=50.9 V, beta_Voc=-0.25%/C, Isc=14.17 A, STC=565.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (553.5 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Hounen Solar America Inc HNM7-UHLDD144-565/N?
Official CEC datasheet figures for Hounen Solar America Inc HNM7-UHLDD144-565/N (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 565.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 530.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.2 V / 13.39 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.25 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.9% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hounen Solar America Inc HNM7-UHLDD144-565/N Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hounen Solar America Inc HNM7-UHLDD144-565/N modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.21 kW | 305 sq ft | $1,554 | $2,628 |
| 8 kW Class | 15 | 8.47 kW | 417 sq ft | $2,120 | $3,585 |
| 10 kW Class | 18 | 10.17 kW | 500 sq ft | $2,545 | $4,304 |
Which Sibling Wattage & Trim Variants Belong to This Hounen Solar America Inc Series?
Consolidated Hounen Solar America Inc wattage variants sharing the Hounen Solar America Inc HNM7-UHLDD144-565/N mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hounen Solar America Inc HNM7-UHLDD144-560/N | 560.0 W | 525.9 W | 50.7 V | 42.0 V | 21.71% |
| Hounen Solar America Inc HNM7-UHLDD144-565/N | 565.0 W | 530.7 W | 50.9 V | 42.2 V | 21.9% |
| Hounen Solar America Inc HNM7-UHLDD144-570/N | 570.0 W | 535.5 W | 51.1 V | 42.4 V | 22.09% |
How Many Hounen Solar America Inc HNM7-UHLDD144-565/N Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hounen Solar America Inc HNM7-UHLDD144-565/N (55.35 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.63 V | 10 panels | 566.3 V | 17 panels |
| -10 C (14 F) | 55.35 V | 10 panels | 553.5 V | 18 panels |
| 0 C (32 F) | 54.08 V | 11 panels | 594.9 V | 18 panels |
| 25 C (77 F STC) | 50.9 V | 11 panels | 559.9 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hounen Solar America Inc HNM7-UHLDD144-565/N?
Competing CEC solar panels closest to Hounen Solar America Inc HNM7-UHLDD144-565/N in nameplate wattage and Voc, starting with GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565 GOLDI SUN PRIVATE LIMITED |
565.0 W | Tie (0 W) | 50.88 V | 21.9% | 94.5% |
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
565.0 W | Tie (0 W) | 50.7 V | 22.07% | 94.1% |
| Gautam Solar Pvt Ltd G2G1695-HAD Gautam Solar Pvt Ltd |
565.0 W | Tie (0 W) | 50.59 V | 22.01% | 95.1% |
| Gautam Solar Pvt Ltd G2X1695N-UHAD Gautam Solar Pvt Ltd |
565.0 W | Tie (0 W) | 50.59 V | 21.98% | 94.8% |
What Are the Design Limits and Best-Fit Uses for Hounen Solar America Inc HNM7-UHLDD144-565/N?
Evaluate Hounen Solar America Inc HNM7-UHLDD144-565/N (565.0 W STC, 50.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hounen Solar America Inc HNM7-UHLDD144-565/N reaches 56.63 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hounen Solar America Inc HNM7-UHLDD144-565/N carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hounen Solar America Inc HNM7-UHLDD144-565/N 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 530.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hounen Solar America Inc HNM7-UHLDD144-565/N by Hounen Solar America Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hounen Solar America Inc HNM7-UHLDD144-565/N?
Multiplying Hounen Solar America Inc HNM7-UHLDD144-565/N's 14.17 A short-circuit current by 1.56 equals 22.11 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hounen Solar America Inc HNM7-UHLDD144-565/N pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 55.35 V cold Voc at 14 F and handles 14.17 A Isc; string inverters cap Hounen Solar America Inc HNM7-UHLDD144-565/N at 10 panels on 600 V.
Is Hounen Solar America Inc HNM7-UHLDD144-565/N eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hounen Solar America Inc HNM7-UHLDD144-565/N rely on utility bill offset (~$2,120/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)