Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 132HC-470 M10 SL is a 470.0 W STC (442.8 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 20.52% efficiency, 45.25 V Voc at 25 C, and 49.21 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
442.8 W
Voc @ 25C
45.25 V
Efficiency
20.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 132HC-470 M10 SL Compare Against Peer CEC Listings?

Solar engineering breakdown for Heliene 132HC-470 M10 SL: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Heliene and peers, Heliene 132HC-470 M10 SL stands 60.0 W above the 410.0 W Mono-c-Si median and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677). Sizing 6 kW (13 panels) to 10 kW (22 panels) yields $1,529-$2,588/yr in baseline US bill offset. Mid-range 45.25 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Heliene 132HC-470 M10 SL Fall Across Listed CEC Models?

Distribution marker showing Heliene 132HC-470 M10 SL (470.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 132HC-470 M10 SL (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 132HC-470 : 470.0 W

What Dataset Percentiles Define Heliene 132HC-470 M10 SL?

Dataset percentiles tracking Heliene 132HC-470 M10 SL power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Heliene 132HC-470 M10 SL Engineering BenchmarksPercentile comparison of Heliene 132HC-470 M10 SL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention94.2%Module Efficiency20.52%

What Do the Dataset Ranks Show for Heliene 132HC-470 M10 SL?

Benchmark highlights for Heliene 132HC-470 M10 SL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,460

20.52% Aperture Efficiency

Power density 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.21 V at -10 C (590.5 V string) and 50.34 V at -20 C (11 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,970 W PTC; NEC 690.8 OCPD floor is 20.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.25 * (1 + (-0.25/100) * (-10 - 25)) = 49.21 V | OCPD = 1.56 * 13.21 = 20.61 A

Inputs from CEC Modules.csv for Heliene 132HC-470 M10 SL: Voc=45.25 V, beta_Voc=-0.25%/C, Isc=13.21 A, STC=470.0 W, Area=2.29 m2.

Result: 12 panels max on 600 V (590.5 V); 18 panels for 8 kW (444 sq ft).

What Are the Published CEC Specifications for Heliene 132HC-470 M10 SL?

Official CEC datasheet figures for Heliene 132HC-470 M10 SL (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Heliene 132HC-470 M10 SL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 442.8 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.25 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.21 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.7 V / 12.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.52% (2.29 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 132HC-470 M10 SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Heliene 132HC-470 M10 SL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 320 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 444 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 542 sq ft $2,588 $4,376

How Many Heliene 132HC-470 M10 SL Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 132HC-470 M10 SL (49.21 V at 14 F).

Computed from Voc=45.25V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.34 V 11 panels 553.7 V 19 panels
-10 C (14 F) 49.21 V 12 panels 590.5 V 20 panels
0 C (32 F) 48.08 V 12 panels 577.0 V 20 panels
25 C (77 F STC) 45.25 V 13 panels 588.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 132HC-470 M10 SL?

Competing CEC solar panels closest to Heliene 132HC-470 M10 SL in nameplate wattage and Voc, starting with Auxin Solar AXN10M470W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M470W
Auxin Solar
470.0 W Tie (0 W) 43.78 V 21.86% 92.0%
Auxin Solar AXN10M465B
Auxin Solar
465.0 W -5.0 W 43.72 V 21.63% 91.6%
Aptos Solar Technology LLC DNA-120-BFN10-470W-DG
Aptos Solar Technology LLC
470.0 W Tie (0 W) 42.38 V 21.76% 94.9%
CSI Solar Co Ltd CS61-60TM-470H
CSI Solar Co Ltd
470.0 W Tie (0 W) 42.0 V 21.46% 94.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 132HC-470 M10 SL?

Evaluate Heliene 132HC-470 M10 SL (470.0 W STC, 45.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 132HC-470 M10 SL reaches 50.34 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (444 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 132HC-470 M10 SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 132HC-470 M10 SL 8 kW Residential Fit

Needs 18 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN10M470W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 132HC-470 M10 SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Heliene 132HC-470 M10 SL?

Multiplying Heliene 132HC-470 M10 SL's 13.21 A short-circuit current by 1.56 equals 20.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Heliene 132HC-470 M10 SL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.21 V cold Voc at 14 F and handles 13.21 A Isc; string inverters cap Heliene 132HC-470 M10 SL at 12 panels on 600 V.

Is Heliene 132HC-470 M10 SL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 132HC-470 M10 SL rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.