Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 60M260 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 60M260 is a 260.0 W STC (234.2 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.63% efficiency, 37.73 V Voc at 25 C, and 42.67 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
234.2 W
Voc @ 25C
37.73 V
Efficiency
15.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 60M260 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 60M260 (Mono-c-Si) residential solar systems. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Homeowners evaluating Heliene 60M260 need 24 panels for 6 kW or 31 panels (555 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (555 sq ft). Under NEC 690.7(A), beta_Voc (-0.374%/C) pushes open-circuit voltage to 42.67 V at 14 F and 44.08 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Heliene 60M260 Fall Across Listed CEC Models?

Comparison of Heliene 60M260 (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 60M260 (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 60M260: 260.0 W

What Dataset Percentiles Define Heliene 60M260?

Relative ranking of Heliene 60M260 across nameplate watts, 90.1% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Heliene 60M260 Engineering BenchmarksPercentile comparison of Heliene 60M260 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention90.1%Module Efficiency15.63%

What Do the Dataset Ranks Show for Heliene 60M260?

Summary of Heliene 60M260 output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,747

15.63% Aperture Efficiency

Power density 156.3 W/m2 (4.28 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.67 V at -10 C (597.4 V string) and 44.08 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 51.6 m2 (555 sq ft) producing 7,260 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.73 * (1 + (-0.374/100) * (-10 - 25)) = 42.67 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for Heliene 60M260: Voc=37.73 V, beta_Voc=-0.374%/C, Isc=8.9 A, STC=260.0 W, Area=1.663 m2.

Result: 14 panels max on 600 V (597.4 V); 31 panels for 8 kW (555 sq ft).

What Are the Published CEC Specifications for Heliene 60M260?

Complete CEC test sheet for Heliene 60M260 including Isc (8.9 A), Voc (37.73 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 60M260.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 234.2 W (90.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.73 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.84 V / 8.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.374 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.63% (1.663 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 60M260 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 60M260.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 430 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 555 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 698 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 60M260 series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 60M260 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 60M250 250.0 W 225.6 W 37.4 V 30.3 V 15.03%
Heliene 60M255 255.0 W 229.6 W 37.5 V 30.65 V 15.33%
Heliene 60M260 260.0 W 234.2 W 37.73 V 30.84 V 15.63%
Heliene 60M265 265.0 W 235.5 W 38.4 V 31.17 V 15.93%
Heliene 60M270 270.0 W 244.1 W 38.92 V 31.31 V 17.39%

How Many Heliene 60M260 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 60M260 (37.73 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.73V and beta_Voc=-0.374%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.08 V 13 panels 573.0 V 22 panels
-10 C (14 F) 42.67 V 14 panels 597.4 V 23 panels
0 C (32 F) 41.26 V 14 panels 577.6 V 24 panels
25 C (77 F STC) 37.73 V 15 panels 565.9 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 60M260?

Four comparable CEC modules such as AXITEC AC-260M/156-60S (260.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-260M/156-60S
AXITEC
260.0 W Tie (0 W) 37.73 V 16.02% 90.2%
Gintung Energy ASEC-260G6M6A
Gintung Energy
260.0 W Tie (0 W) 37.78 V 16.14% 88.1%
Auxin Solar AXN6M610T260
Auxin Solar
260.0 W Tie (0 W) 37.8 V 15.87% 89.6%
CSI Solar Co Ltd CS6P-260M
CSI Solar Co Ltd
260.0 W Tie (0 W) 37.8 V 16.79% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 60M260?

Evaluate Heliene 60M260 (260.0 W STC, 37.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 60M260 reaches 44.08 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 555 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (555 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 60M260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 60M260 8 kW Residential Fit

Needs 31 modules (555 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260M/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 60M260 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Why is Heliene 60M260 PTC wattage (234.2 W) lower than STC (260.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 234.2 W PTC (90.1% retention) across Heliene 60M260's 1.663 m2 aperture.

Who should skip Heliene 60M260 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Heliene 60M260 panels (555 sq ft) leave unusable roof gaps vs. AXITEC AC-260M/156-60S.

What is the 1,000 V commercial string limit for Heliene 60M260?

On 1,000 V commercial inverters at -10 C (42.67 V cold Voc), Heliene 60M260 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 60M260.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.