Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72M-380 Bifacial — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M-380 Bifacial is a 380.0 W STC (348.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.43% efficiency, 50.51 V Voc at 25 C, and 55.28 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
348.6 W
Voc @ 25C
50.51 V
Efficiency
20.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M-380 Bifacial Compare Against Peer CEC Listings?

How Heliene Heliene 72M-380 Bifacial handles rooftop heat (348.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Heliene 72M-380 Bifacial exhibits 9.63 A short-circuit current, requiring a 15.02 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 40.9 m2 for an 8 kW system (27 panels for 10 kW). Higher 50.51 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Heliene 72M-380 Bifacial Fall Across Listed CEC Models?

Where Heliene 72M-380 Bifacial (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M-380 Bifacial (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M-380 Bi: 380.0 W

What Dataset Percentiles Define Heliene 72M-380 Bifacial?

Percentile placement of Heliene 72M-380 Bifacial across power density (204.3 W/m2), thermal retention, and nameplate STC wattage.

Heliene 72M-380 Bifacial Engineering BenchmarksPercentile comparison of Heliene 72M-380 Bifacial wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention91.7%Module Efficiency20.43%

What Do the Dataset Ranks Show for Heliene 72M-380 Bifacial?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 72M-380 Bifacial specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,886

20.43% Aperture Efficiency

Power density 204.3 W/m2 (0.52 percentage points above 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.28 V at -10 C (552.8 V string) and 56.65 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,669 W PTC; NEC 690.8 OCPD floor is 15.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.51 * (1 + (-0.27/100) * (-10 - 25)) = 55.28 V | OCPD = 1.56 * 9.63 = 15.02 A

Inputs from CEC Modules.csv for Heliene 72M-380 Bifacial: Voc=50.51 V, beta_Voc=-0.27%/C, Isc=9.63 A, STC=380.0 W, Area=1.86 m2.

Result: 10 panels max on 600 V (552.8 V); 22 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for Heliene 72M-380 Bifacial?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 72M-380 Bifacial.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-380 Bifacial.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 348.6 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.51 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.2 V / 9.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.43% (1.86 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Heliene 72M-380 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 72M-380 Bifacial (380.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 320 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 440 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 541 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 72M-380 Bifacial architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Heliene 72M-380 Bifacial wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72M-375 Bifacial 375.0 W 343.9 W 47.19 V 41.34 V 20.16%
Heliene 72M-380 Bifacial 380.0 W 348.6 W 50.51 V 41.2 V 20.43%
Heliene 72M-385 Bifacial 385.0 W 353.4 W 47.9 V 41.76 V 20.7%

How Many Heliene 72M-380 Bifacial Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 72M-380 Bifacial from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.51V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.65 V 10 panels 566.5 V 17 panels
-10 C (14 F) 55.28 V 10 panels 552.8 V 18 panels
0 C (32 F) 53.92 V 11 panels 593.1 V 18 panels
25 C (77 F STC) 50.51 V 11 panels 555.6 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-380 Bifacial?

Alternative CEC solar modules from competing brands near Heliene 72M-380 Bifacial (380.0 W), including Auxin Solar AXN6M612B380. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.06% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M-380 Bifacial?

Evaluate Heliene 72M-380 Bifacial (380.0 W STC, 50.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-380 Bifacial reaches 56.65 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 440 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (440 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72M-380 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M-380 Bifacial 8 kW Residential Fit

Needs 22 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN6M612B380.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 348.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-380 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Heliene 72M-380 Bifacial PTC wattage (348.6 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 348.6 W PTC (91.7% retention) across Heliene 72M-380 Bifacial's 1.86 m2 aperture.

Who should skip Heliene 72M-380 Bifacial on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Heliene 72M-380 Bifacial panels (440 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612B380.

What is the 1,000 V commercial string limit for Heliene 72M-380 Bifacial?

On 1,000 V commercial inverters at -10 C (55.28 V cold Voc), Heliene 72M-380 Bifacial fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 72M-380 Bifacial.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.