Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72P310 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72P310 is a 310.0 W STC (276.2 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.87% efficiency, 45.66 V Voc at 25 C, and 51.03 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
276.2 W
Voc @ 25C
45.66 V
Efficiency
16.87%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72P310 Compare Against Peer CEC Listings?

Engineering position of Heliene 72P310 (310.0 W STC) vs. Centrosolar America DM72 310 across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Heliene 72P310 pairs typical 89.1% PTC-to-STC thermal output (276.2 W real-world rating) with 45.66 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,181 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM72 310 offers a 310.0 W alternative.

Where Does Heliene 72P310 Fall Across Listed CEC Models?

Plots Heliene 72P310 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72P310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72P310: 310.0 W

What Dataset Percentiles Define Heliene 72P310?

Benchmarks Heliene 72P310 on STC wattage, thermal PTC/STC retention, and 16.87 aperture conversion efficiency against CEC peers.

Heliene 72P310 Engineering BenchmarksPercentile comparison of Heliene 72P310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention89.1%Module Efficiency16.87%

What Do the Dataset Ranks Show for Heliene 72P310?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 72P310 by Heliene.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,673

16.87% Aperture Efficiency

Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.03 V at -10 C (561.3 V string) and 52.56 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 47.8 m2 (514 sq ft) producing 7,181 W PTC; NEC 690.8 OCPD floor is 13.74 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.66 * (1 + (-0.336/100) * (-10 - 25)) = 51.03 V | OCPD = 1.56 * 8.81 = 13.74 A

Inputs from CEC Modules.csv for Heliene 72P310: Voc=45.66 V, beta_Voc=-0.336%/C, Isc=8.81 A, STC=310.0 W, Area=1.838 m2.

Result: 11 panels max on 600 V (561.3 V); 26 panels for 8 kW (514 sq ft).

What Are the Published CEC Specifications for Heliene 72P310?

Laboratory test ratings recorded for Heliene 72P310 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72P310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 276.2 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.66 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.81 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.2 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.336 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.87% (1.838 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Heliene 72P310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (514 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 72P310.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 396 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 514 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 653 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Sibling wattage bins and frame colors grouped with Heliene 72P310 under Heliene to prevent duplicate spec pages. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Heliene 72P310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72P300 300.0 W 267.0 W 45.3 V 36.91 V 16.32%
Heliene 72P305 305.0 W 271.6 W 45.51 V 37.06 V 16.59%
Heliene 72P310 310.0 W 276.2 W 45.66 V 37.2 V 16.87%
Heliene 72P315 315.0 W 280.8 W 45.81 V 37.33 V 17.14%
Heliene 72P320 320.0 W 285.4 W 45.96 V 37.42 V 17.41%

How Many Heliene 72P310 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 72P310 (beta_Voc -0.336%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.66V and beta_Voc=-0.336%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.56 V 11 panels 578.2 V 19 panels
-10 C (14 F) 51.03 V 11 panels 561.3 V 19 panels
0 C (32 F) 49.5 V 12 panels 594.0 V 20 panels
25 C (77 F STC) 45.66 V 13 panels 593.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72P310?

Closest cross-brand CEC competitors to Heliene 72P310 matched near 310.0 W STC and 45.66 V Voc, led by Centrosolar America DM72 310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 310
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.94% 90.8%
Centrosolar America TP7 310xx
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.89% 90.5%
Centrosolar America TP7S 310xx
Centrosolar America
310.0 W Tie (0 W) 45.7 V 15.89% 90.5%
DEHUI SOLAR POWER INC DH-72P-310W
DEHUI SOLAR POWER INC
310.0 W Tie (0 W) 45.6 V 16.12% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72P310?

Evaluate Heliene 72P310 (310.0 W STC, 45.66 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72P310 reaches 52.56 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 514 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (514 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72P310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72P310 8 kW Residential Fit

Needs 26 modules (514 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 276.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72P310 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

What fuse or breaker size does NEC 690.8 require for Heliene 72P310?

Multiplying Heliene 72P310's 8.81 A short-circuit current by 1.56 equals 13.74 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 72P310 before finalizing component orders.

Can Heliene 72P310 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.03 V cold Voc at 14 F and handles 8.81 A Isc; string inverters cap Heliene 72P310 at 11 panels on 600 V.

Is Heliene 72P310 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 72P310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.