Heliene 108HC-435 M10 NTYP SL is a 435.0 W STC (411.1 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.31% efficiency, 38.5 V Voc at 25 C, and 41.72 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 411.1 W
- Voc @ 25C
- 38.5 V
- Efficiency
- 22.31%
How Does Heliene 108HC-435 M10 NTYP SL Compare Against Peer CEC Listings?
Solar engineering breakdown for Heliene 108HC-435 M10 NTYP SL: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 435.0 W STC and 411.1 W PTC, Heliene 108HC-435 M10 NTYP SL sits +50.0 W vs all-CEC median (top 33.5%; higher than 66.5% of peers) among 21,677 listed modules. Power density reaches 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). Lower 38.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer AXITEC AC-435TGB/108BB rates 435.0 W.
Where Does Heliene 108HC-435 M10 NTYP SL Fall Across Listed CEC Models?
Distribution marker showing Heliene 108HC-435 M10 NTYP SL (435.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Heliene 108HC-435 M10 NTYP SL?
Dataset percentiles tracking Heliene 108HC-435 M10 NTYP SL power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Heliene 108HC-435 M10 NTYP SL?
Benchmark highlights for Heliene 108HC-435 M10 NTYP SL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.31% Aperture Efficiency
Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.72 V at -10 C (584.1 V string) and 42.64 V at -20 C (14 max).
19 Panels = 8,265 W STC
Occupies 37.0 m2 (399 sq ft) producing 7,811 W PTC; NEC 690.8 OCPD floor is 22.18 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.5 * (1 + (-0.239/100) * (-10 - 25)) = 41.72 V | OCPD = 1.56 * 14.22 = 22.18 A
Inputs from CEC Modules.csv for Heliene 108HC-435 M10 NTYP SL: Voc=38.5 V, beta_Voc=-0.239%/C, Isc=14.22 A, STC=435.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (584.1 V); 19 panels for 8 kW (399 sq ft).
What Are the Published CEC Specifications for Heliene 108HC-435 M10 NTYP SL?
Official CEC datasheet figures for Heliene 108HC-435 M10 NTYP SL (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 411.1 W (94.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.72 V / 13.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.239 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.31% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 108HC-435 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Heliene 108HC-435 M10 NTYP SL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 294 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 399 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 483 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Consolidated Heliene wattage variants sharing the Heliene 108HC-435 M10 NTYP SL mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 108HC-425 M10 NTYP SL | 425.0 W | 401.4 W | 38.29 V | 32.18 V | 21.79% |
| Heliene 108HC-430 M10 NTYP SL | 430.0 W | 406.2 W | 38.42 V | 32.45 V | 22.05% |
| Heliene 108HC-435 M10 NTYP SL | 435.0 W | 411.1 W | 38.5 V | 32.72 V | 22.31% |
| Heliene 108HC-440 M10 NTYP SL | 440.0 W | 415.9 W | 38.63 V | 32.98 V | 22.56% |
How Many Heliene 108HC-435 M10 NTYP SL Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 108HC-435 M10 NTYP SL (41.72 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.64 V | 14 panels | 597.0 V | 23 panels |
| -10 C (14 F) | 41.72 V | 14 panels | 584.1 V | 23 panels |
| 0 C (32 F) | 40.8 V | 14 panels | 571.2 V | 24 panels |
| 25 C (77 F STC) | 38.5 V | 15 panels | 577.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 108HC-435 M10 NTYP SL?
Competing CEC solar panels closest to Heliene 108HC-435 M10 NTYP SL in nameplate wattage and Voc, starting with AXITEC AC-435TGB/108BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-435TGB/108BB AXITEC |
435.0 W | Tie (0 W) | 38.43 V | 22.89% | 95.0% |
| Auxin Solar AXN10M435B Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| Auxin Solar AXN10M435W Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 Elin Energy (Sirius PV) |
435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Heliene 108HC-435 M10 NTYP SL?
Evaluate Heliene 108HC-435 M10 NTYP SL (435.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 108HC-435 M10 NTYP SL reaches 42.64 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Heliene 108HC-435 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 108HC-435 M10 NTYP SL 8 kW Residential Fit
Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-435TGB/108BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 108HC-435 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
How many Heliene 108HC-435 M10 NTYP SL panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 108HC-435 M10 NTYP SL cold Voc rises from 38.5 V to 41.72 V (beta_Voc -0.239%/C), capping a 600 V string at 14 panels (584.1 V).
How much roof area does an 8 kW array of Heliene 108HC-435 M10 NTYP SL need?
An 8 kW DC system uses 19 Heliene 108HC-435 M10 NTYP SL modules (8,265 W STC / 7,811 W PTC), covering roughly 399 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does Heliene 108HC-435 M10 NTYP SL compare against AXITEC AC-435TGB/108BB?
Heliene 108HC-435 M10 NTYP SL outputs 435.0 W STC (38.5 V Voc, rank #6,850 of 21,677), while AXITEC AC-435TGB/108BB delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)