Recom RCM-290-6PA — CEC Solar Module Specifications

Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-290-6PA is a 290.0 W STC (261.5 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 44.8 V Voc at 25 C, and 49.66 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
261.5 W
Voc @ 25C
44.8 V
Efficiency
14.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-290-6PA Compare Against Peer CEC Listings?

How Recom Recom RCM-290-6PA handles rooftop heat (261.5 W PTC), 8 kW sizing, and cold winter string voltage.

Recom builds the Recom RCM-290-6PA (Multi-c-Si) as a compact residential or specialty off-grid module delivering 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). Compared against Gintung Energy GTEC-290G6S (290.0 W), this model holds typical 90.2% PTC-to-STC thermal output (261.5 W real-world rating). Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.35 A overcurrent floor served by a 15 A breaker.

Where Does Recom RCM-290-6PA Fall Across Listed CEC Models?

Where Recom RCM-290-6PA (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-290-6PA (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-290-6PA: 290.0 W

What Dataset Percentiles Define Recom RCM-290-6PA?

Percentile placement of Recom RCM-290-6PA across power density (149.5 W/m2), thermal retention, and nameplate STC wattage. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Recom RCM-290-6PA Engineering BenchmarksPercentile comparison of Recom RCM-290-6PA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.2%Module Efficiency14.95%

What Do the Dataset Ranks Show for Recom RCM-290-6PA?

Four critical engineering numbers homeowners and solar installers check first when reviewing Recom RCM-290-6PA specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,805

14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.66 V at -10 C (595.9 V string) and 51.05 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.31/100) * (-10 - 25)) = 49.66 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Recom RCM-290-6PA: Voc=44.8 V, beta_Voc=-0.31%/C, Isc=8.56 A, STC=290.0 W, Area=1.94 m2.

Result: 12 panels max on 600 V (595.9 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for Recom RCM-290-6PA?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Recom RCM-290-6PA. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-290-6PA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 261.5 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.3 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.95% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Recom RCM-290-6PA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Recom RCM-290-6PA (290.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 585 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 731 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

All closely matched Recom wattages and cosmetic trims sharing the Recom RCM-290-6PA architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Recom RCM-290-6PA wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-285-6PA 285.0 W 256.9 W 44.7 V 36.2 V 14.69%
Recom RCM-290-6PA 290.0 W 261.5 W 44.8 V 36.3 V 14.95%
Recom RCM-295-6PA 295.0 W 266.2 W 44.9 V 36.4 V 15.2%

How Many Recom RCM-290-6PA Modules Fit in a Cold-Weather String?

Maximum series module counts for Recom RCM-290-6PA from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.8V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.05 V 11 panels 561.5 V 19 panels
-10 C (14 F) 49.66 V 12 panels 595.9 V 20 panels
0 C (32 F) 48.27 V 12 panels 579.2 V 20 panels
25 C (77 F STC) 44.8 V 13 panels 582.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-290-6PA?

Alternative CEC solar modules from competing brands near Recom RCM-290-6PA (290.0 W), including Gintung Energy GTEC-290G6S. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-290-6PA?

Evaluate Recom RCM-290-6PA (290.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-290-6PA reaches 51.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-290-6PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-290-6PA 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy GTEC-290G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 261.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-290-6PA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

What fuse or breaker size does NEC 690.8 require for Recom RCM-290-6PA?

Multiplying Recom RCM-290-6PA's 8.56 A short-circuit current by 1.56 equals 13.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-290-6PA before finalizing component orders.

Can Recom RCM-290-6PA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.66 V cold Voc at 14 F and handles 8.56 A Isc; string inverters cap Recom RCM-290-6PA at 12 panels on 600 V.

Is Recom RCM-290-6PA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-290-6PA rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.