Skip to main content
WireAndSun
Calculators
CEC Brand Hub

Recom — CEC Certified Solar Equipment Catalog

Registry: California Energy Commission (CEC) Verified: 2026-11-26

Recom holds 9 verified California Energy Commission (CEC) certifications including 9 module series (250–345W PV). Recom carries 9 module series ranging from 250 W to 345 W STC (median 290 W vs 385 W CEC fleet median; 16.3% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

Manufacturer
Recom
PV Module Series
9
Listed Inverters
0
Output Range
250–345W PV
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Do Recom Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Recom photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Recom hardware for residential interconnection can verify exact DC and AC test data across 9 CEC records. Recom carries 9 module series ranging from 250 W to 345 W STC (median 290 W vs 385 W CEC fleet median; 16.3% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Recom in our federal recall archive as of 2026.

Which Recom PV Module Series Are CEC Certified? (9)

Inspect Recom photovoltaic panel series sorted from highest STC wattage downward; near-identical wattage trims are grouped inside each series page.

Deduplicated CEC photovoltaic module series for Recom.
Module Series STC (W) PTC (W) Voc (V) Eff (%) Variants
Recom RCM-345-6MA 345.0 313.5 47.9 17.78 5
Recom RCM-330-6PA 330.0 300.6 46.51 17.01 2
Recom RCM-320-6MA 320.0 290.1 46.8 16.49 2
Recom RCM-300-6PA 300.0 270.8 44.8 15.46 5
Recom RCM-290-6PA 290.0 261.5 44.8 14.95 3
Recom RCM-280-6MB-BB 280.0 253.7 39.2 17.19 2
Recom RCM-265-6MB-BB 265.0 239.7 38.64 16.27 3
Recom RCM-260-6MB 260.0 234.7 38.52 15.98 3
Recom RCM-250-6PB 250.0 222.7 37.1 15.37 3
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom Solar Hardware?

Evaluate Recom CEC certifications (250–345W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

  • Recom certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
  • Constrained roofs: Recom's median module aperture efficiency (16.3%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

Recom Module + Third-Party Inverter

Pair Recom modules (250–345W PV) with microinverters or string inverters rated above local cold-weather Voc.

Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Permitting and engineering takeaways specific to Recom photovoltaic and inverter hardware listed on the CEC registry. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

How many Recom solar models are verified on the CEC list?

Our CEC archive indexes 9 Recom equipment records (9 module series and 0 inverter models) spanning 250–345W PV. Check local building department permit requirements for Recom before finalizing component orders.

What should homeowners check before approving Recom equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

How efficient are Recom solar panels compared to CEC averages?

Across listed series, Recom modules show a median aperture efficiency of 16.3% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Recom.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
  4. CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.