Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-250-6PB is a 250.0 W STC (222.7 W PTC) Multi-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.37% efficiency, 37.1 V Voc at 25 C, and 41.39 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
250.0 W
PTC Wattage
222.7 W
Voc @ 25C
37.1 V
Efficiency
15.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-250-6PB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Recom RCM-250-6PB (Multi-c-Si) residential solar systems. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Recom RCM-250-6PB delivers 153.7 W/m2 (4.54 percentage points below 19.91% CEC median) and typical 89.1% PTC-to-STC thermal output (222.7 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (560 sq ft). At -4 F (-20 C), string voltage climbs to 42.61 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Eoplly New Energy Technology EP156MB/60-250S AC (250.0 W).

Where Does Recom RCM-250-6PB Fall Across Listed CEC Models?

Comparison of Recom RCM-250-6PB (250.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-250-6PB (250.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-250-6PB: 250.0 W

What Dataset Percentiles Define Recom RCM-250-6PB?

Relative ranking of Recom RCM-250-6PB across nameplate watts, 89.1% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Recom RCM-250-6PB Engineering BenchmarksPercentile comparison of Recom RCM-250-6PB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage250.0 WPTC/STC Retention89.1%Module Efficiency15.37%

What Do the Dataset Ranks Show for Recom RCM-250-6PB?

Summary of Recom RCM-250-6PB output rank, 8 kW array size (32 panels), efficiency rating, and 600 V string limit.

Rank #19,686 / 21,677

250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,164

15.37% Aperture Efficiency

Power density 153.7 W/m2 (4.54 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.39 V at -10 C (579.5 V string) and 42.61 V at -20 C (14 max).

8 kW Reference Array

32 Panels = 8,000 W STC

Occupies 52.1 m2 (560 sq ft) producing 7,126 W PTC; NEC 690.8 OCPD floor is 13.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.33/100) * (-10 - 25)) = 41.39 V | OCPD = 1.56 * 8.92 = 13.92 A

Inputs from CEC Modules.csv for Recom RCM-250-6PB: Voc=37.1 V, beta_Voc=-0.33%/C, Isc=8.92 A, STC=250.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (579.5 V); 32 panels for 8 kW (560 sq ft).

What Are the Published CEC Specifications for Recom RCM-250-6PB?

Complete CEC test sheet for Recom RCM-250-6PB including Isc (8.92 A), Voc (37.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-250-6PB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 250.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 222.7 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.2 V / 8.35 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.37% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Recom RCM-250-6PB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Recom RCM-250-6PB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.0 kW 420 sq ft $1,502 $2,539
8 kW Class 32 8.0 kW 560 sq ft $2,002 $3,386
10 kW Class 40 10.0 kW 701 sq ft $2,503 $4,232

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Related Recom power steps and black/silver trims consolidated into this Recom RCM-250-6PB series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Recom RCM-250-6PB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-250-6PB 250.0 W 222.7 W 37.1 V 30.2 V 15.37%
Recom RCM-255-6PB 255.0 W 227.2 W 37.6 V 30.5 V 15.67%
Recom RCM-260-6PB 260.0 W 231.8 W 38.0 V 30.8 V 15.98%

How Many Recom RCM-250-6PB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Recom RCM-250-6PB (37.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.1V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.61 V 14 panels 596.5 V 23 panels
-10 C (14 F) 41.39 V 14 panels 579.5 V 24 panels
0 C (32 F) 40.16 V 14 panels 562.2 V 24 panels
25 C (77 F STC) 37.1 V 16 panels 593.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-250-6PB?

Four comparable CEC modules such as Eoplly New Energy Technology EP156MB/60-250S AC (250.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Eoplly New Energy Technology EP156MB/60-250S AC
Eoplly New Energy Technology
250.0 W Tie (0 W) 37.26 V 15.45% 89.6%
Anji Technology AJP-M660-250
Anji Technology
250.0 W Tie (0 W) 37.32 V 15.4% 89.0%
Boviet Solar Technology Co Ltd BVM6610P-250
Boviet Solar Technology Co Ltd
250.0 W Tie (0 W) 37.5 V 15.37% 90.2%
Changzhou Nesl Solartech DJ-250DA/C-ST15
Changzhou Nesl Solartech
250.0 W Tie (0 W) 38.07 V 15.3% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-250-6PB?

Evaluate Recom RCM-250-6PB (250.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-250-6PB reaches 42.61 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (560 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-250-6PB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-250-6PB 8 kW Residential Fit

Needs 32 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Eoplly New Energy Technology EP156MB/60-250S AC.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 222.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-250-6PB by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many Recom RCM-250-6PB panels fit on a 600 V winter solar string?

At -10 C (14 F), Recom RCM-250-6PB cold Voc rises from 37.1 V to 41.39 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (579.5 V).

How much roof area does an 8 kW array of Recom RCM-250-6PB need?

An 8 kW DC system uses 32 Recom RCM-250-6PB modules (8,000 W STC / 7,126 W PTC), covering roughly 560 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Recom RCM-250-6PB compare against Eoplly New Energy Technology EP156MB/60-250S AC?

Recom RCM-250-6PB outputs 250.0 W STC (37.1 V Voc, rank #19,686 of 21,677), while Eoplly New Energy Technology EP156MB/60-250S AC delivers 250.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.