Skip to main content
WireAndSun
Calculators
CEC PV Module

Recom RCM-330-6PA — CEC Solar Module Specifications

Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-330-6PA is a 330.0 W STC (300.6 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.51 V Voc at 25 C, and 51.39 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
300.6 W
Voc @ 25C
46.51 V
Efficiency
17.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-330-6PA Compare Against Peer CEC Listings?

Engineering position of Recom RCM-330-6PA (330.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Recom RCM-330-6PA pairs typical 91.1% PTC-to-STC thermal output (300.6 W real-world rating) with 46.51 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,515 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W offers a 330.0 W alternative.

Where Does Recom RCM-330-6PA Fall Across Listed CEC Models?

Plots Recom RCM-330-6PA at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-330-6PA (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-330-6PA: 330.0 W

What Dataset Percentiles Define Recom RCM-330-6PA?

Benchmarks Recom RCM-330-6PA on STC wattage, thermal PTC/STC retention, and 17.01 aperture conversion efficiency against CEC peers.

Recom RCM-330-6PA Engineering BenchmarksPercentile comparison of Recom RCM-330-6PA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention91.1%Module Efficiency17.01%

What Do the Dataset Ranks Show for Recom RCM-330-6PA?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Recom RCM-330-6PA by Recom.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,431

17.01% Aperture Efficiency

Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.39 V at -10 C (565.3 V string) and 52.79 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,515 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.51 * (1 + (-0.3/100) * (-10 - 25)) = 51.39 V | OCPD = 1.56 * 9.07 = 14.15 A

Inputs from CEC Modules.csv for Recom RCM-330-6PA: Voc=46.51 V, beta_Voc=-0.3%/C, Isc=9.07 A, STC=330.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (565.3 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for Recom RCM-330-6PA?

Laboratory test ratings recorded for Recom RCM-330-6PA (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-330-6PA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 300.6 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.51 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.83 V / 8.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.01% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Recom RCM-330-6PA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for Recom RCM-330-6PA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 397 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 522 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 647 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Sibling wattage bins and frame colors grouped with Recom RCM-330-6PA under Recom to prevent duplicate spec pages. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Recom RCM-330-6PA wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-325-6PA 325.0 W 295.9 W 46.15 V 38.47 V 16.75%
Recom RCM-330-6PA 330.0 W 300.6 W 46.51 V 38.83 V 17.01%

How Many Recom RCM-330-6PA Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Recom RCM-330-6PA (beta_Voc -0.3%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.51V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.79 V 11 panels 580.7 V 18 panels
-10 C (14 F) 51.39 V 11 panels 565.3 V 19 panels
0 C (32 F) 50.0 V 12 panels 600.0 V 20 panels
25 C (77 F STC) 46.51 V 12 panels 558.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-330-6PA?

Closest cross-brand CEC competitors to Recom RCM-330-6PA matched near 330.0 W STC and 46.51 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330BW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330SW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-330-6PA?

Evaluate Recom RCM-330-6PA (330.0 W STC, 46.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-330-6PA reaches 52.79 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-330-6PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-330-6PA 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 300.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-330-6PA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

What fuse or breaker size does NEC 690.8 require for Recom RCM-330-6PA?

Multiplying Recom RCM-330-6PA's 9.07 A short-circuit current by 1.56 equals 14.15 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-330-6PA before finalizing component orders.

Can Recom RCM-330-6PA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.39 V cold Voc at 14 F and handles 9.07 A Isc; string inverters cap Recom RCM-330-6PA at 11 panels on 600 V.

Is Recom RCM-330-6PA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-330-6PA rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.