Recom RCM-320-6MA — CEC Solar Module Specifications

Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-320-6MA is a 320.0 W STC (290.1 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.49% efficiency, 46.8 V Voc at 25 C, and 51.88 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
290.1 W
Voc @ 25C
46.8 V
Efficiency
16.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-320-6MA Compare Against Peer CEC Listings?

Engineering position of Recom RCM-320-6MA (320.0 W STC) vs. Centrosolar America EM72 320BW across 5,889 CEC Mono-c-Si solar modules.

Ranking #14,944 across 21,677 CEC solar panels (below all-CEC median; higher than 29.0% of peers), Recom RCM-320-6MA operates as a compact residential or specialty off-grid module sitting 90.0 W below the 410.0 W Mono-c-Si median. Mid-range 46.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 90.7% PTC-to-STC thermal output (290.1 W real-world rating), 25 panels occupy 522 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Recom RCM-320-6MA Fall Across Listed CEC Models?

Plots Recom RCM-320-6MA at 320.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-320-6MA (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-320-6MA: 320.0 W

What Dataset Percentiles Define Recom RCM-320-6MA?

Benchmarks Recom RCM-320-6MA on STC wattage, thermal PTC/STC retention, and 16.49 aperture conversion efficiency against CEC peers.

Recom RCM-320-6MA Engineering BenchmarksPercentile comparison of Recom RCM-320-6MA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention90.7%Module Efficiency16.49%

What Do the Dataset Ranks Show for Recom RCM-320-6MA?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Recom RCM-320-6MA by Recom.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,316

16.49% Aperture Efficiency

Power density 164.9 W/m2 (3.42 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.88 V at -10 C (570.7 V string) and 53.33 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,252 W PTC; NEC 690.8 OCPD floor is 13.65 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.8 * (1 + (-0.31/100) * (-10 - 25)) = 51.88 V | OCPD = 1.56 * 8.75 = 13.65 A

Inputs from CEC Modules.csv for Recom RCM-320-6MA: Voc=46.8 V, beta_Voc=-0.31%/C, Isc=8.75 A, STC=320.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (570.7 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for Recom RCM-320-6MA?

Laboratory test ratings recorded for Recom RCM-320-6MA (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-320-6MA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 290.1 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.75 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.3 V / 8.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.49% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Recom RCM-320-6MA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for Recom RCM-320-6MA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 397 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 522 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 668 sq ft $2,563 $4,334

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Sibling wattage bins and frame colors grouped with Recom RCM-320-6MA under Recom to prevent duplicate spec pages. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Recom RCM-320-6MA wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-315-6MA 315.0 W 285.5 W 46.7 V 38.2 V 16.23%
Recom RCM-320-6MA 320.0 W 290.1 W 46.8 V 38.3 V 16.49%

How Many Recom RCM-320-6MA Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Recom RCM-320-6MA (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.8V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.33 V 11 panels 586.6 V 18 panels
-10 C (14 F) 51.88 V 11 panels 570.7 V 19 panels
0 C (32 F) 50.43 V 11 panels 554.7 V 19 panels
25 C (77 F STC) 46.8 V 12 panels 561.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-320-6MA?

Closest cross-brand CEC competitors to Recom RCM-320-6MA matched near 320.0 W STC and 46.8 V Voc, led by Centrosolar America EM72 320BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EM72 320BW
Centrosolar America
320.0 W Tie (0 W) 46.31 V 16.64% 91.3%
Centrosolar America EM72 320SW
Centrosolar America
320.0 W Tie (0 W) 46.31 V 16.64% 91.3%
Bluesun Solar Energy Tech CoLtd BSM320P-72
Bluesun Solar Energy Tech CoLtd
320.0 W Tie (0 W) 46.19 V 16.51% 91.3%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
320.0 W Tie (0 W) 45.94 V 16.64% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-320-6MA?

Evaluate Recom RCM-320-6MA (320.0 W STC, 46.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-320-6MA reaches 53.33 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-320-6MA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-320-6MA 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EM72 320BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 290.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-320-6MA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

How many Recom RCM-320-6MA panels fit on a 600 V winter solar string?

At -10 C (14 F), Recom RCM-320-6MA cold Voc rises from 46.8 V to 51.88 V (beta_Voc -0.31%/C), capping a 600 V string at 11 panels (570.7 V).

How much roof area does an 8 kW array of Recom RCM-320-6MA need?

An 8 kW DC system uses 25 Recom RCM-320-6MA modules (8,000 W STC / 7,252 W PTC), covering roughly 522 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Recom RCM-320-6MA compare against Centrosolar America EM72 320BW?

Recom RCM-320-6MA outputs 320.0 W STC (46.8 V Voc, rank #14,944 of 21,677), while Centrosolar America EM72 320BW delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?