Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America EM72 320BW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EM72 320BW is a 320.0 W STC (292.1 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.64% efficiency, 46.31 V Voc at 25 C, and 51.12 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
292.1 W
Voc @ 25C
46.31 V
Efficiency
16.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EM72 320BW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America EM72 320BW (Mono-c-Si) residential solar systems.

Centrosolar America EM72 320BW delivers 166.4 W/m2 (3.27 percentage points below 19.91% CEC median) and typical 91.3% PTC-to-STC thermal output (292.1 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (517 sq ft). At -4 F (-20 C), string voltage climbs to 52.5 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Bluesun Solar Energy Tech CoLtd BSM320P-72 (320.0 W).

Where Does Centrosolar America EM72 320BW Fall Across Listed CEC Models?

Comparison of Centrosolar America EM72 320BW (320.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EM72 320BW (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 320.0 W

What Dataset Percentiles Define Centrosolar America EM72 320BW?

Relative ranking of Centrosolar America EM72 320BW across nameplate watts, 91.3% PTC thermal ratio, and module aperture efficiency.

Centrosolar America EM72 320BW Engineering BenchmarksPercentile comparison of Centrosolar America EM72 320BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention91.3%Module Efficiency16.64%

What Do the Dataset Ranks Show for Centrosolar America EM72 320BW?

Summary of Centrosolar America EM72 320BW output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,097

16.64% Aperture Efficiency

Power density 166.4 W/m2 (3.27 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.12 V at -10 C (562.3 V string) and 52.5 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 48.1 m2 (517 sq ft) producing 7,302 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.31 * (1 + (-0.297/100) * (-10 - 25)) = 51.12 V | OCPD = 1.56 * 9.08 = 14.16 A

Inputs from CEC Modules.csv for Centrosolar America EM72 320BW: Voc=46.31 V, beta_Voc=-0.297%/C, Isc=9.08 A, STC=320.0 W, Area=1.923 m2.

Result: 11 panels max on 600 V (562.3 V); 25 panels for 8 kW (517 sq ft).

What Are the Published CEC Specifications for Centrosolar America EM72 320BW?

Complete CEC test sheet for Centrosolar America EM72 320BW including Isc (9.08 A), Voc (46.31 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EM72 320BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 292.1 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.31 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.08 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.0 V / 8.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.297 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.64% (1.923 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America EM72 320BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America EM72 320BW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 393 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 517 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 662 sq ft $2,563 $4,334

How Many Centrosolar America EM72 320BW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America EM72 320BW (46.31 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.31V and beta_Voc=-0.297%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.5 V 11 panels 577.5 V 19 panels
-10 C (14 F) 51.12 V 11 panels 562.3 V 19 panels
0 C (32 F) 49.75 V 12 panels 597.0 V 20 panels
25 C (77 F STC) 46.31 V 12 panels 555.7 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EM72 320BW?

Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM320P-72 (320.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM320P-72
Bluesun Solar Energy Tech CoLtd
320.0 W Tie (0 W) 46.19 V 16.51% 91.3%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
320.0 W Tie (0 W) 45.94 V 16.64% 91.2%
AXITEC AC-320P/72S
AXITEC
320.0 W Tie (0 W) 45.82 V 16.58% 92.2%
AXITEC AC-320P/72V
AXITEC
320.0 W Tie (0 W) 45.82 V 16.58% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EM72 320BW?

Evaluate Centrosolar America EM72 320BW (320.0 W STC, 46.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EM72 320BW reaches 52.5 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 517 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (517 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EM72 320BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EM72 320BW 8 kW Residential Fit

Needs 25 modules (517 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM320P-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EM72 320BW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Centrosolar America EM72 320BW panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America EM72 320BW cold Voc rises from 46.31 V to 51.12 V (beta_Voc -0.297%/C), capping a 600 V string at 11 panels (562.3 V).

How much roof area does an 8 kW array of Centrosolar America EM72 320BW need?

An 8 kW DC system uses 25 Centrosolar America EM72 320BW modules (8,000 W STC / 7,302 W PTC), covering roughly 517 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Centrosolar America EM72 320BW compare against Bluesun Solar Energy Tech CoLtd BSM320P-72?

Centrosolar America EM72 320BW outputs 320.0 W STC (46.31 V Voc, rank #14,944 of 21,677), while Bluesun Solar Energy Tech CoLtd BSM320P-72 delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.