Recom RCM-280-6MB-BB is a 280.0 W STC (253.7 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.19% efficiency, 39.2 V Voc at 25 C, and 43.59 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 253.7 W
- Voc @ 25C
- 39.2 V
- Efficiency
- 17.19%
How Does Recom RCM-280-6MB-BB Compare Against Peer CEC Listings?
Solar engineering breakdown for Recom RCM-280-6MB-BB: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Across 5,889 Mono-c-Si listings from Recom and peers, Recom RCM-280-6MB-BB stands 130.0 W below the 410.0 W Mono-c-Si median and typical 90.6% PTC-to-STC thermal output (253.7 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Lower 39.2 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Recom RCM-280-6MB-BB Fall Across Listed CEC Models?
Distribution marker showing Recom RCM-280-6MB-BB (280.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define Recom RCM-280-6MB-BB?
Dataset percentiles tracking Recom RCM-280-6MB-BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for Recom RCM-280-6MB-BB?
Benchmark highlights for Recom RCM-280-6MB-BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.19% Aperture Efficiency
Power density 171.9 W/m2 (2.72 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.59 V at -10 C (566.7 V string) and 44.84 V at -20 C (13 max).
29 Panels = 8,120 W STC
Occupies 47.2 m2 (508 sq ft) producing 7,357 W PTC; NEC 690.8 OCPD floor is 14.02 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.2 * (1 + (-0.32/100) * (-10 - 25)) = 43.59 V | OCPD = 1.56 * 8.99 = 14.02 A
Inputs from CEC Modules.csv for Recom RCM-280-6MB-BB: Voc=39.2 V, beta_Voc=-0.32%/C, Isc=8.99 A, STC=280.0 W, Area=1.629 m2.
Result: 13 panels max on 600 V (566.7 V); 29 panels for 8 kW (508 sq ft).
What Are the Published CEC Specifications for Recom RCM-280-6MB-BB?
Official CEC datasheet figures for Recom RCM-280-6MB-BB (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 253.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.5 V / 8.67 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.19% (1.629 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Recom RCM-280-6MB-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Recom RCM-280-6MB-BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 386 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 508 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 631 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Recom Series?
Consolidated Recom wattage variants sharing the Recom RCM-280-6MB-BB mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Recom RCM-275-6MB-BB | 275.0 W | 249.0 W | 38.98 V | 32.31 V | 16.88% |
| Recom RCM-280-6MB-BB | 280.0 W | 253.7 W | 39.2 V | 32.5 V | 17.19% |
How Many Recom RCM-280-6MB-BB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Recom RCM-280-6MB-BB (43.59 V at 14 F). Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.84 V | 13 panels | 582.9 V | 22 panels |
| -10 C (14 F) | 43.59 V | 13 panels | 566.7 V | 22 panels |
| 0 C (32 F) | 42.34 V | 14 panels | 592.8 V | 23 panels |
| 25 C (77 F STC) | 39.2 V | 15 panels | 588.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Recom RCM-280-6MB-BB?
Competing CEC solar panels closest to Recom RCM-280-6MB-BB in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America EP60 280BW Centrosolar America |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America EP60 280SW Centrosolar America |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America EM60 280BB Centrosolar America |
280.0 W | Tie (0 W) | 39.26 V | 17.38% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Recom RCM-280-6MB-BB?
Evaluate Recom RCM-280-6MB-BB (280.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-280-6MB-BB reaches 44.84 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 508 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (508 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-280-6MB-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Recom RCM-280-6MB-BB 8 kW Residential Fit
Needs 29 modules (508 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Recom RCM-280-6MB-BB by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What fuse or breaker size does NEC 690.8 require for Recom RCM-280-6MB-BB?
Multiplying Recom RCM-280-6MB-BB's 8.99 A short-circuit current by 1.56 equals 14.02 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-280-6MB-BB before finalizing component orders.
Can Recom RCM-280-6MB-BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.59 V cold Voc at 14 F and handles 8.99 A Isc; string inverters cap Recom RCM-280-6MB-BB at 13 panels on 600 V.
Is Recom RCM-280-6MB-BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-280-6MB-BB rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)