Recom RCM-345-6MA — CEC Solar Module Specifications

Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-345-6MA is a 345.0 W STC (313.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.78% efficiency, 47.9 V Voc at 25 C, and 53.1 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
313.5 W
Voc @ 25C
47.9 V
Efficiency
17.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-345-6MA Compare Against Peer CEC Listings?

Solar engineering breakdown for Recom RCM-345-6MA: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Across 5,889 Mono-c-Si listings from Recom and peers, Recom RCM-345-6MA stands 65.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (313.5 W real-world rating). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,554-$2,505/yr in baseline US bill offset. Mid-range 47.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Recom RCM-345-6MA Fall Across Listed CEC Models?

Distribution marker showing Recom RCM-345-6MA (345.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-345-6MA (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-345-6MA: 345.0 W

What Dataset Percentiles Define Recom RCM-345-6MA?

Dataset percentiles tracking Recom RCM-345-6MA power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Recom RCM-345-6MA Engineering BenchmarksPercentile comparison of Recom RCM-345-6MA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention90.9%Module Efficiency17.78%

What Do the Dataset Ranks Show for Recom RCM-345-6MA?

Benchmark highlights for Recom RCM-345-6MA covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,390

17.78% Aperture Efficiency

Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.1 V at -10 C (584.1 V string) and 54.58 V at -20 C (10 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.9 * (1 + (-0.31/100) * (-10 - 25)) = 53.1 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for Recom RCM-345-6MA: Voc=47.9 V, beta_Voc=-0.31%/C, Isc=9.05 A, STC=345.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (584.1 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for Recom RCM-345-6MA?

Official CEC datasheet figures for Recom RCM-345-6MA (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-345-6MA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 313.5 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.9 V / 8.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.78% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Recom RCM-345-6MA Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Recom RCM-345-6MA modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 376 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 501 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 606 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Consolidated Recom wattage variants sharing the Recom RCM-345-6MA mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Recom RCM-345-6MA wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-325-6MA 325.0 W 294.8 W 47.0 V 38.4 V 16.75%
Recom RCM-330-6MA 330.0 W 299.5 W 47.1 V 38.5 V 17.01%
Recom RCM-335-6MA 335.0 W 304.1 W 47.4 V 38.7 V 17.26%
Recom RCM-340-6MA 340.0 W 308.8 W 47.6 V 38.8 V 17.52%
Recom RCM-345-6MA 345.0 W 313.5 W 47.9 V 38.9 V 17.78%

How Many Recom RCM-345-6MA Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Recom RCM-345-6MA (53.1 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Computed from Voc=47.9V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.58 V 10 panels 545.8 V 18 panels
-10 C (14 F) 53.1 V 11 panels 584.1 V 18 panels
0 C (32 F) 51.61 V 11 panels 567.7 V 19 panels
25 C (77 F STC) 47.9 V 12 panels 574.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-345-6MA?

Competing CEC solar panels closest to Recom RCM-345-6MA in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72345.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 47.3 V 17.78% 91.6%
AXITEC AC-345M/156-72S
AXITEC
345.0 W Tie (0 W) 47.0 V 17.78% 91.4%
GCL System Integration Technology Co Ltd GCL-P3/72H345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.88 V 17.16% 93.1%
GCL System Integration Technology Co Ltd GCL-M6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.8 V 17.78% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-345-6MA?

Evaluate Recom RCM-345-6MA (345.0 W STC, 47.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-345-6MA reaches 54.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-345-6MA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-345-6MA 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72345.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-345-6MA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

What fuse or breaker size does NEC 690.8 require for Recom RCM-345-6MA?

Multiplying Recom RCM-345-6MA's 9.05 A short-circuit current by 1.56 equals 14.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-345-6MA before finalizing component orders.

Can Recom RCM-345-6MA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.1 V cold Voc at 14 F and handles 9.05 A Isc; string inverters cap Recom RCM-345-6MA at 11 panels on 600 V.

Is Recom RCM-345-6MA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-345-6MA rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.