Recom RCM-345-6MA is a 345.0 W STC (313.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.78% efficiency, 47.9 V Voc at 25 C, and 53.1 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 313.5 W
- Voc @ 25C
- 47.9 V
- Efficiency
- 17.78%
How Does Recom RCM-345-6MA Compare Against Peer CEC Listings?
Solar engineering breakdown for Recom RCM-345-6MA: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Across 5,889 Mono-c-Si listings from Recom and peers, Recom RCM-345-6MA stands 65.0 W below the 410.0 W Mono-c-Si median and typical 90.9% PTC-to-STC thermal output (313.5 W real-world rating). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,554-$2,505/yr in baseline US bill offset. Mid-range 47.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Recom RCM-345-6MA Fall Across Listed CEC Models?
Distribution marker showing Recom RCM-345-6MA (345.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Recom RCM-345-6MA?
Dataset percentiles tracking Recom RCM-345-6MA power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for Recom RCM-345-6MA?
Benchmark highlights for Recom RCM-345-6MA covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.78% Aperture Efficiency
Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.1 V at -10 C (584.1 V string) and 54.58 V at -20 C (10 max).
24 Panels = 8,280 W STC
Occupies 46.6 m2 (501 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.9 * (1 + (-0.31/100) * (-10 - 25)) = 53.1 V | OCPD = 1.56 * 9.05 = 14.12 A
Inputs from CEC Modules.csv for Recom RCM-345-6MA: Voc=47.9 V, beta_Voc=-0.31%/C, Isc=9.05 A, STC=345.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (584.1 V); 24 panels for 8 kW (501 sq ft).
What Are the Published CEC Specifications for Recom RCM-345-6MA?
Official CEC datasheet figures for Recom RCM-345-6MA (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 313.5 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.9 V / 8.91 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.78% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Recom RCM-345-6MA Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Recom RCM-345-6MA modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 376 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 501 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 606 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Recom Series?
Consolidated Recom wattage variants sharing the Recom RCM-345-6MA mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Recom RCM-325-6MA | 325.0 W | 294.8 W | 47.0 V | 38.4 V | 16.75% |
| Recom RCM-330-6MA | 330.0 W | 299.5 W | 47.1 V | 38.5 V | 17.01% |
| Recom RCM-335-6MA | 335.0 W | 304.1 W | 47.4 V | 38.7 V | 17.26% |
| Recom RCM-340-6MA | 340.0 W | 308.8 W | 47.6 V | 38.8 V | 17.52% |
| Recom RCM-345-6MA | 345.0 W | 313.5 W | 47.9 V | 38.9 V | 17.78% |
How Many Recom RCM-345-6MA Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Recom RCM-345-6MA (53.1 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.58 V | 10 panels | 545.8 V | 18 panels |
| -10 C (14 F) | 53.1 V | 11 panels | 584.1 V | 18 panels |
| 0 C (32 F) | 51.61 V | 11 panels | 567.7 V | 19 panels |
| 25 C (77 F STC) | 47.9 V | 12 panels | 574.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Recom RCM-345-6MA?
Competing CEC solar panels closest to Recom RCM-345-6MA in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72345.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Recom RCM-345-6MA?
Evaluate Recom RCM-345-6MA (345.0 W STC, 47.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-345-6MA reaches 54.58 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-345-6MA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Recom RCM-345-6MA 8 kW Residential Fit
Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72345.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Recom RCM-345-6MA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for Recom RCM-345-6MA?
Multiplying Recom RCM-345-6MA's 9.05 A short-circuit current by 1.56 equals 14.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-345-6MA before finalizing component orders.
Can Recom RCM-345-6MA pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.1 V cold Voc at 14 F and handles 9.05 A Isc; string inverters cap Recom RCM-345-6MA at 11 panels on 600 V.
Is Recom RCM-345-6MA eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-345-6MA rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)