Recom RCM-300-6PA is a 300.0 W STC (270.8 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.46% efficiency, 44.8 V Voc at 25 C, and 49.66 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 270.8 W
- Voc @ 25C
- 44.8 V
- Efficiency
- 15.46%
How Does Recom RCM-300-6PA Compare Against Peer CEC Listings?
How Recom Recom RCM-300-6PA handles rooftop heat (270.8 W PTC), 8 kW sizing, and cold winter string voltage.
Recom builds the Recom RCM-300-6PA (Multi-c-Si) as a compact residential or specialty off-grid module delivering 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6P612T305G (305.0 W), this model holds typical 90.3% PTC-to-STC thermal output (270.8 W real-world rating). Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.56 A overcurrent floor served by a 15 A breaker.
Where Does Recom RCM-300-6PA Fall Across Listed CEC Models?
Where Recom RCM-300-6PA (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Recom RCM-300-6PA?
Percentile placement of Recom RCM-300-6PA across power density (154.6 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for Recom RCM-300-6PA?
Four critical engineering numbers homeowners and solar installers check first when reviewing Recom RCM-300-6PA specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.46% Aperture Efficiency
Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.66 V at -10 C (595.9 V string) and 51.05 V at -20 C (11 max).
27 Panels = 8,100 W STC
Occupies 52.4 m2 (564 sq ft) producing 7,312 W PTC; NEC 690.8 OCPD floor is 13.56 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.8 * (1 + (-0.31/100) * (-10 - 25)) = 49.66 V | OCPD = 1.56 * 8.69 = 13.56 A
Inputs from CEC Modules.csv for Recom RCM-300-6PA: Voc=44.8 V, beta_Voc=-0.31%/C, Isc=8.69 A, STC=300.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (595.9 V); 27 panels for 8 kW (564 sq ft).
What Are the Published CEC Specifications for Recom RCM-300-6PA?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Recom RCM-300-6PA. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 270.8 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.6 V / 8.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.46% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Recom RCM-300-6PA Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Recom RCM-300-6PA (300.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 418 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 564 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 710 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Recom Series?
All closely matched Recom wattages and cosmetic trims sharing the Recom RCM-300-6PA architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Recom RCM-300-6PA | 300.0 W | 270.8 W | 44.8 V | 36.6 V | 15.46% |
| Recom RCM-305-6PA | 305.0 W | 275.4 W | 44.95 V | 36.82 V | 15.72% |
| Recom RCM-310-6PA | 310.0 W | 280.1 W | 45.0 V | 37.0 V | 15.98% |
| Recom RCM-315-6PA | 315.0 W | 286.6 W | 45.4 V | 37.8 V | 16.23% |
| Recom RCM-320-6PA | 320.0 W | 291.2 W | 45.94 V | 38.23 V | 16.49% |
How Many Recom RCM-300-6PA Modules Fit in a Cold-Weather String?
Maximum series module counts for Recom RCM-300-6PA from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.05 V | 11 panels | 561.5 V | 19 panels |
| -10 C (14 F) | 49.66 V | 12 panels | 595.9 V | 20 panels |
| 0 C (32 F) | 48.27 V | 12 panels | 579.2 V | 20 panels |
| 25 C (77 F STC) | 44.8 V | 13 panels | 582.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Recom RCM-300-6PA?
Alternative CEC solar modules from competing brands near Recom RCM-300-6PA (300.0 W), including Auxin Solar AXN6P612T305G. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T305G Auxin Solar |
305.0 W | +5.0 W | 45.0 V | 15.63% | 90.3% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | +10.0 W | 44.9 V | 16.31% | 91.4% |
| Anhui Rinengzhongtian Semiconductor Development QJM310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | +10.0 W | 44.65 V | 15.98% | 90.0% |
| Anhui Rinengzhongtian Semiconductor Development QJP310-72 Anhui Rinengzhongtian Semiconductor Development |
310.0 W | +10.0 W | 44.65 V | 15.98% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Recom RCM-300-6PA?
Evaluate Recom RCM-300-6PA (300.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-300-6PA reaches 51.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-300-6PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Recom RCM-300-6PA 8 kW Residential Fit
Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Recom RCM-300-6PA by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What fuse or breaker size does NEC 690.8 require for Recom RCM-300-6PA?
Multiplying Recom RCM-300-6PA's 8.69 A short-circuit current by 1.56 equals 13.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-300-6PA before finalizing component orders.
Can Recom RCM-300-6PA pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.66 V cold Voc at 14 F and handles 8.69 A Isc; string inverters cap Recom RCM-300-6PA at 12 panels on 600 V.
Is Recom RCM-300-6PA eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-300-6PA rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)