Anhui Rinengzhongtian Semiconductor Development QJP310-72 is a 310.0 W STC (281.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 44.65 V Voc at 25 C, and 49.81 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 281.0 W
- Voc @ 25C
- 44.65 V
- Efficiency
- 15.98%
How Does Anhui Rinengzhongtian Semiconductor Development QJP310-72 Compare Against Peer CEC Listings?
How Anhui Rinengzhongtian Semiconductor Development Anhui Rinengzhongtian Semiconductor Development QJP310-72 handles rooftop heat (281.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Anhui Rinengzhongtian Semiconductor Development QJP310-72 exhibits 9.14 A short-circuit current, requiring a 14.26 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #15,760 of 21,677 (31.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.4 m2 for an 8 kW system (33 panels for 10 kW). Mid-range 44.65 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Anhui Rinengzhongtian Semiconductor Development QJP310-72 Fall Across Listed CEC Models?
Where Anhui Rinengzhongtian Semiconductor Development QJP310-72 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJP310-72?
Percentile placement of Anhui Rinengzhongtian Semiconductor Development QJP310-72 across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJP310-72?
Four critical engineering numbers homeowners and solar installers check first when reviewing Anhui Rinengzhongtian Semiconductor Development QJP310-72 specifications.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.81 V at -10 C (597.7 V string) and 51.28 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 14.26 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.65 * (1 + (-0.33/100) * (-10 - 25)) = 49.81 V | OCPD = 1.56 * 9.14 = 14.26 A
Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJP310-72: Voc=44.65 V, beta_Voc=-0.33%/C, Isc=9.14 A, STC=310.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (597.7 V); 26 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJP310-72?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Anhui Rinengzhongtian Semiconductor Development QJP310-72.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 281.0 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.65 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 8.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Anhui Rinengzhongtian Semiconductor Development QJP310-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Anhui Rinengzhongtian Semiconductor Development QJP310-72 (310.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 418 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 689 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Anhui Rinengzhongtian Semiconductor Development Series?
All closely matched Anhui Rinengzhongtian Semiconductor Development wattages and cosmetic trims sharing the Anhui Rinengzhongtian Semiconductor Development QJP310-72 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP300-72 | 300.0 W | 268.3 W | 43.4 V | 36.2 V | 15.46% |
| Anhui Rinengzhongtian Semiconductor Development QJP305-72 | 305.0 W | 276.4 W | 44.53 V | 36.2 V | 15.72% |
| Anhui Rinengzhongtian Semiconductor Development QJP310-72 | 310.0 W | 281.0 W | 44.65 V | 36.3 V | 15.98% |
| Anhui Rinengzhongtian Semiconductor Development QJP315-72 | 315.0 W | 285.7 W | 44.77 V | 36.4 V | 16.23% |
| Anhui Rinengzhongtian Semiconductor Development QJP320-72 | 320.0 W | 290.3 W | 44.9 V | 36.5 V | 16.49% |
How Many Anhui Rinengzhongtian Semiconductor Development QJP310-72 Modules Fit in a Cold-Weather String?
Maximum series module counts for Anhui Rinengzhongtian Semiconductor Development QJP310-72 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.28 V | 11 panels | 564.1 V | 19 panels |
| -10 C (14 F) | 49.81 V | 12 panels | 597.7 V | 20 panels |
| 0 C (32 F) | 48.33 V | 12 panels | 580.0 V | 20 panels |
| 25 C (77 F STC) | 44.65 V | 13 panels | 580.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJP310-72?
Alternative CEC solar modules from competing brands near Anhui Rinengzhongtian Semiconductor Development QJP310-72 (310.0 W), including CSI Solar Co Ltd CS6X-310P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | Tie (0 W) | 44.9 V | 16.31% | 91.4% |
| Auxin Solar AXN6M612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.0 V | 15.89% | 89.4% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJP310-72?
Evaluate Anhui Rinengzhongtian Semiconductor Development QJP310-72 (310.0 W STC, 44.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJP310-72 reaches 51.28 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJP310-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Anhui Rinengzhongtian Semiconductor Development QJP310-72 8 kW Residential Fit
Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6X-310P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Anhui Rinengzhongtian Semiconductor Development QJP310-72 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Anhui Rinengzhongtian Semiconductor Development QJP310-72 PTC wattage (281.0 W) lower than STC (310.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 281.0 W PTC (90.6% retention) across Anhui Rinengzhongtian Semiconductor Development QJP310-72's 1.94 m2 aperture.
Who should skip Anhui Rinengzhongtian Semiconductor Development QJP310-72 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 Anhui Rinengzhongtian Semiconductor Development QJP310-72 panels (543 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6X-310P.
What is the 1,000 V commercial string limit for Anhui Rinengzhongtian Semiconductor Development QJP310-72?
On 1,000 V commercial inverters at -10 C (49.81 V cold Voc), Anhui Rinengzhongtian Semiconductor Development QJP310-72 fits up to 20 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)