Anhui Rinengzhongtian Semiconductor Development QJM330-72 is a 330.0 W STC (297.5 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 45.26 V Voc at 25 C, and 50.63 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
297.5 W
Voc @ 25C
45.26 V
Efficiency
17.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Anhui Rinengzhongtian Semiconductor Development QJM330-72 Compare Against Peer CEC Listings?

Engineering position of Anhui Rinengzhongtian Semiconductor Development QJM330-72 (330.0 W STC) vs. CSI Solar Co Ltd CS6X-330P across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Anhui Rinengzhongtian Semiconductor Development QJM330-72 pairs typical 90.2% PTC-to-STC thermal output (297.5 W real-world rating) with 45.26 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,438 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS6X-330P offers a 330.0 W alternative.

Where Does Anhui Rinengzhongtian Semiconductor Development QJM330-72 Fall Across Listed CEC Models?

Plots Anhui Rinengzhongtian Semiconductor Development QJM330-72 at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Anhui Rinengzhongtian Semiconductor Development QJM330-72 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAnhui Rinengzhongt: 330.0 W

What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Benchmarks Anhui Rinengzhongtian Semiconductor Development QJM330-72 on STC wattage, thermal PTC/STC retention, and 17.01 aperture conversion efficiency against CEC peers.

Anhui Rinengzhongtian Semiconductor Development QJM330-72 Engineering BenchmarksPercentile comparison of Anhui Rinengzhongtian Semiconductor Development QJM330-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.2%Module Efficiency17.01%

What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Anhui Rinengzhongtian Semiconductor Development QJM330-72 by Anhui Rinengzhongtian Semiconductor Development.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,431

17.01% Aperture Efficiency

Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.63 V at -10 C (556.9 V string) and 52.16 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,438 W PTC; NEC 690.8 OCPD floor is 14.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.26 * (1 + (-0.339/100) * (-10 - 25)) = 50.63 V | OCPD = 1.56 * 9.6 = 14.98 A

Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJM330-72: Voc=45.26 V, beta_Voc=-0.339%/C, Isc=9.6 A, STC=330.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (556.9 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Laboratory test ratings recorded for Anhui Rinengzhongtian Semiconductor Development QJM330-72 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Anhui Rinengzhongtian Semiconductor Development QJM330-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 297.5 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.8 V / 8.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.01% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Anhui Rinengzhongtian Semiconductor Development QJM330-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for Anhui Rinengzhongtian Semiconductor Development QJM330-72.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 397 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 522 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 647 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Anhui Rinengzhongtian Semiconductor Development Series?

Sibling wattage bins and frame colors grouped with Anhui Rinengzhongtian Semiconductor Development QJM330-72 under Anhui Rinengzhongtian Semiconductor Development to prevent duplicate spec pages.

Sibling CEC listings grouped into the Anhui Rinengzhongtian Semiconductor Development QJM330-72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Anhui Rinengzhongtian Semiconductor Development QJM325-72 325.0 W 292.9 W 45.14 V 36.7 V 16.75%
Anhui Rinengzhongtian Semiconductor Development QJM330-72 330.0 W 297.5 W 45.26 V 36.8 V 17.01%

How Many Anhui Rinengzhongtian Semiconductor Development QJM330-72 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Anhui Rinengzhongtian Semiconductor Development QJM330-72 (beta_Voc -0.339%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.26V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.16 V 11 panels 573.8 V 19 panels
-10 C (14 F) 50.63 V 11 panels 556.9 V 19 panels
0 C (32 F) 49.1 V 12 panels 589.2 V 20 panels
25 C (77 F STC) 45.26 V 13 panels 588.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Closest cross-brand CEC competitors to Anhui Rinengzhongtian Semiconductor Development QJM330-72 matched near 330.0 W STC and 45.26 V Voc, led by CSI Solar Co Ltd CS6X-330P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6X-330P
CSI Solar Co Ltd
330.0 W Tie (0 W) 45.6 V 17.36% 91.6%
Centrosolar America DP72 330
Centrosolar America
330.0 W Tie (0 W) 45.8 V 16.97% 90.4%
AXITEC AC-330P/72S
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
AXITEC AC-330P/72V
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Evaluate Anhui Rinengzhongtian Semiconductor Development QJM330-72 (330.0 W STC, 45.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJM330-72 reaches 52.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJM330-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Anhui Rinengzhongtian Semiconductor Development QJM330-72 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6X-330P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 297.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Anhui Rinengzhongtian Semiconductor Development QJM330-72 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Anhui Rinengzhongtian Semiconductor Development QJM330-72?

Multiplying Anhui Rinengzhongtian Semiconductor Development QJM330-72's 9.6 A short-circuit current by 1.56 equals 14.98 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Anhui Rinengzhongtian Semiconductor Development QJM330-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.63 V cold Voc at 14 F and handles 9.6 A Isc; string inverters cap Anhui Rinengzhongtian Semiconductor Development QJM330-72 at 11 panels on 600 V.

Is Anhui Rinengzhongtian Semiconductor Development QJM330-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Anhui Rinengzhongtian Semiconductor Development QJM330-72 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.