Recom RCM-260-6MB is a 260.0 W STC (234.7 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 38.52 V Voc at 25 C, and 42.83 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 234.7 W
- Voc @ 25C
- 38.52 V
- Efficiency
- 15.98%
How Does Recom RCM-260-6MB Compare Against Peer CEC Listings?
Engineering position of Recom RCM-260-6MB (260.0 W STC) vs. BYD Company Limited BYD 260P6C-30 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Recom RCM-260-6MB pairs typical 90.3% PTC-to-STC thermal output (234.7 W real-world rating) with 38.52 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,276 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD 260P6C-30 offers a 260.0 W alternative.
Where Does Recom RCM-260-6MB Fall Across Listed CEC Models?
Plots Recom RCM-260-6MB at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Recom RCM-260-6MB?
Benchmarks Recom RCM-260-6MB on STC wattage, thermal PTC/STC retention, and 15.98 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Recom RCM-260-6MB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Recom RCM-260-6MB by Recom.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.83 V at -10 C (599.6 V string) and 44.07 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.52 * (1 + (-0.32/100) * (-10 - 25)) = 42.83 V | OCPD = 1.56 * 8.66 = 13.51 A
Inputs from CEC Modules.csv for Recom RCM-260-6MB: Voc=38.52 V, beta_Voc=-0.32%/C, Isc=8.66 A, STC=260.0 W, Area=1.627 m2.
Result: 14 panels max on 600 V (599.6 V); 31 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Recom RCM-260-6MB?
Laboratory test ratings recorded for Recom RCM-260-6MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 234.7 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 8.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Recom RCM-260-6MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for Recom RCM-260-6MB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 683 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Recom Series?
Sibling wattage bins and frame colors grouped with Recom RCM-260-6MB under Recom to prevent duplicate spec pages. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Recom RCM-250-6MB | 250.0 W | 225.4 W | 37.92 V | 31.3 V | 15.37% |
| Recom RCM-260-6MB | 260.0 W | 234.7 W | 38.52 V | 31.7 V | 15.98% |
| Recom RCM-270-6MB | 270.0 W | 244.0 W | 38.76 V | 32.12 V | 16.6% |
How Many Recom RCM-260-6MB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Recom RCM-260-6MB (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.07 V | 13 panels | 572.9 V | 22 panels |
| -10 C (14 F) | 42.83 V | 14 panels | 599.6 V | 23 panels |
| 0 C (32 F) | 41.6 V | 14 panels | 582.4 V | 24 panels |
| 25 C (77 F STC) | 38.52 V | 15 panels | 577.8 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Recom RCM-260-6MB?
Closest cross-brand CEC competitors to Recom RCM-260-6MB matched near 260.0 W STC and 38.52 V Voc, led by BYD Company Limited BYD 260P6C-30.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD 260P6C-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| BYD Company Limited BYD260P6K-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |
| Centrosolar America DP60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |
| Centrosolar America DM60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.2 V | 15.86% | 90.8% |
What Are the Design Limits and Best-Fit Uses for Recom RCM-260-6MB?
Evaluate Recom RCM-260-6MB (260.0 W STC, 38.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-260-6MB reaches 44.07 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Recom RCM-260-6MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Recom RCM-260-6MB 8 kW Residential Fit
Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare BYD Company Limited BYD 260P6C-30.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Recom RCM-260-6MB by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What fuse or breaker size does NEC 690.8 require for Recom RCM-260-6MB?
Multiplying Recom RCM-260-6MB's 8.66 A short-circuit current by 1.56 equals 13.51 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Recom RCM-260-6MB before finalizing component orders.
Can Recom RCM-260-6MB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.83 V cold Voc at 14 F and handles 8.66 A Isc; string inverters cap Recom RCM-260-6MB at 14 panels on 600 V.
Is Recom RCM-260-6MB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Recom RCM-260-6MB rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)