Centrosolar America DP60 260 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DP60 260 is a 260.0 W STC (234.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.86% efficiency, 38.28 V Voc at 25 C, and 42.82 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
234.4 W
Voc @ 25C
38.28 V
Efficiency
15.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DP60 260 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DP60 260: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Centrosolar America and peers, Centrosolar America DP60 260 stands 18.8 W below the 278.8 W Multi-c-Si median and typical 90.2% PTC-to-STC thermal output (234.4 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 38.28 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Centrosolar America DP60 260 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DP60 260 (260.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DP60 260 (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 260.0 W

What Dataset Percentiles Define Centrosolar America DP60 260?

Dataset percentiles tracking Centrosolar America DP60 260 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Centrosolar America DP60 260 Engineering BenchmarksPercentile comparison of Centrosolar America DP60 260 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention90.2%Module Efficiency15.86%

What Do the Dataset Ranks Show for Centrosolar America DP60 260?

Benchmark highlights for Centrosolar America DP60 260 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,383

15.86% Aperture Efficiency

Power density 158.5 W/m2 (4.05 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.82 V at -10 C (599.5 V string) and 44.12 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.8 m2 (547 sq ft) producing 7,266 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.28 * (1 + (-0.339/100) * (-10 - 25)) = 42.82 V | OCPD = 1.56 * 8.7 = 13.57 A

Inputs from CEC Modules.csv for Centrosolar America DP60 260: Voc=38.28 V, beta_Voc=-0.339%/C, Isc=8.7 A, STC=260.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (599.5 V); 31 panels for 8 kW (547 sq ft).

What Are the Published CEC Specifications for Centrosolar America DP60 260?

Official CEC datasheet figures for Centrosolar America DP60 260 (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP60 260.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 234.4 W (90.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.28 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.71 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.86% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America DP60 260 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DP60 260 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 424 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 547 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 688 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Consolidated Centrosolar America wattage variants sharing the Centrosolar America DP60 260 mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Centrosolar America DP60 260 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DP60 250 250.0 W 225.3 W 37.65 V 30.83 V 15.25%
Centrosolar America DP60 255 255.0 W 226.2 W 37.9 V 31.25 V 15.55%
Centrosolar America DP60 260 260.0 W 234.4 W 38.28 V 31.71 V 15.86%
Centrosolar America DP60 265 265.0 W 239.1 W 38.4 V 32.2 V 16.16%
Centrosolar America DP60 270 270.0 W 243.7 W 38.6 V 32.46 V 16.47%

How Many Centrosolar America DP60 260 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP60 260 (42.82 V at 14 F).

Computed from Voc=38.28V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.12 V 13 panels 573.6 V 22 panels
-10 C (14 F) 42.82 V 14 panels 599.5 V 23 panels
0 C (32 F) 41.52 V 14 panels 581.3 V 24 panels
25 C (77 F STC) 38.28 V 15 panels 574.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP60 260?

Competing CEC solar panels closest to Centrosolar America DP60 260 in nameplate wattage and Voc, starting with BYD Company Limited BYD 260P6C-30.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD 260P6C-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.98% 90.4%
BYD Company Limited BYD260P6K-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.95% 91.7%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
260.0 W Tie (0 W) 38.0 V 16.01% 88.5%
Chinaland Solar Energy HSE260-60M
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 16.01% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DP60 260?

Evaluate Centrosolar America DP60 260 (260.0 W STC, 38.28 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP60 260 reaches 44.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DP60 260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DP60 260 8 kW Residential Fit

Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare BYD Company Limited BYD 260P6C-30.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP60 260 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America DP60 260?

Multiplying Centrosolar America DP60 260's 8.7 A short-circuit current by 1.56 equals 13.57 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America DP60 260 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.82 V cold Voc at 14 F and handles 8.7 A Isc; string inverters cap Centrosolar America DP60 260 at 14 panels on 600 V.

Is Centrosolar America DP60 260 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP60 260 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.