Skip to main content
WireAndSun
Calculators
CEC PV Module

Recom RCM-265-6MB-BB — CEC Solar Module Specifications

Manufacturer: Recom Registry: CEC Verified Engineering Specification

Recom RCM-265-6MB-BB is a 265.0 W STC (239.7 W PTC) Mono-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.27% efficiency, 38.64 V Voc at 25 C, and 42.97 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
239.7 W
Voc @ 25C
38.64 V
Efficiency
16.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Recom RCM-265-6MB-BB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Recom RCM-265-6MB-BB (Mono-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Homeowners evaluating Recom RCM-265-6MB-BB need 23 panels for 6 kW or 31 panels (544 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (544 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 42.97 V at 14 F and 44.2 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Recom RCM-265-6MB-BB Fall Across Listed CEC Models?

Comparison of Recom RCM-265-6MB-BB (265.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Recom RCM-265-6MB-BB (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRecom RCM-265-6MB-: 265.0 W

What Dataset Percentiles Define Recom RCM-265-6MB-BB?

Relative ranking of Recom RCM-265-6MB-BB across nameplate watts, 90.5% PTC thermal ratio, and module aperture efficiency. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Recom RCM-265-6MB-BB Engineering BenchmarksPercentile comparison of Recom RCM-265-6MB-BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention90.5%Module Efficiency16.27%

What Do the Dataset Ranks Show for Recom RCM-265-6MB-BB?

Summary of Recom RCM-265-6MB-BB output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,702

16.27% Aperture Efficiency

Power density 162.7 W/m2 (3.64 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.97 V at -10 C (558.6 V string) and 44.2 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.5 m2 (544 sq ft) producing 7,431 W PTC; NEC 690.8 OCPD floor is 13.6 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.64 * (1 + (-0.32/100) * (-10 - 25)) = 42.97 V | OCPD = 1.56 * 8.72 = 13.6 A

Inputs from CEC Modules.csv for Recom RCM-265-6MB-BB: Voc=38.64 V, beta_Voc=-0.32%/C, Isc=8.72 A, STC=265.0 W, Area=1.629 m2.

Result: 13 panels max on 600 V (558.6 V); 31 panels for 8 kW (544 sq ft).

What Are the Published CEC Specifications for Recom RCM-265-6MB-BB?

Complete CEC test sheet for Recom RCM-265-6MB-BB including Isc (8.72 A), Voc (38.64 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Recom RCM-265-6MB-BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 239.7 W (90.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.91 V / 8.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.27% (1.629 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Recom RCM-265-6MB-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Recom RCM-265-6MB-BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 403 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 544 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 666 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Recom Series?

Related Recom power steps and black/silver trims consolidated into this Recom RCM-265-6MB-BB series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Recom RCM-265-6MB-BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Recom RCM-260-6MB-BB 260.0 W 235.1 W 38.52 V 31.7 V 15.96%
Recom RCM-265-6MB-BB 265.0 W 239.7 W 38.64 V 31.91 V 16.27%
Recom RCM-270-6MB-BB 270.0 W 244.4 W 38.76 V 32.12 V 16.58%

How Many Recom RCM-265-6MB-BB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Recom RCM-265-6MB-BB (38.64 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.64V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.2 V 13 panels 574.6 V 22 panels
-10 C (14 F) 42.97 V 13 panels 558.6 V 23 panels
0 C (32 F) 41.73 V 14 panels 584.2 V 23 panels
25 C (77 F STC) 38.64 V 15 panels 579.6 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Recom RCM-265-6MB-BB?

Four comparable CEC modules such as Centrosolar America CP60 265-C1 (265.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America CP60 265-C1
Centrosolar America
265.0 W Tie (0 W) 38.3 V 16.29% 90.4%
GermanSolar USA GSM6-60-265W
GermanSolar USA
265.0 W Tie (0 W) 38.3 V 16.29% 90.5%
Centrosolar America EM60 265BB
Centrosolar America
265.0 W Tie (0 W) 38.29 V 16.45% 91.0%
Centrosolar America EP60 265BW
Centrosolar America
265.0 W Tie (0 W) 38.29 V 16.45% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Recom RCM-265-6MB-BB?

Evaluate Recom RCM-265-6MB-BB (265.0 W STC, 38.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Recom RCM-265-6MB-BB reaches 44.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (544 sq ft).
  • 2026 tax credit baseline: cash residential installs of Recom RCM-265-6MB-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Recom RCM-265-6MB-BB 8 kW Residential Fit

Needs 31 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America CP60 265-C1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 239.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Recom RCM-265-6MB-BB by Recom grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Why is Recom RCM-265-6MB-BB PTC wattage (239.7 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 239.7 W PTC (90.5% retention) across Recom RCM-265-6MB-BB's 1.629 m2 aperture.

Who should skip Recom RCM-265-6MB-BB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Recom RCM-265-6MB-BB panels (544 sq ft) leave unusable roof gaps vs. Centrosolar America CP60 265-C1.

What is the 1,000 V commercial string limit for Recom RCM-265-6MB-BB?

On 1,000 V commercial inverters at -10 C (42.97 V cold Voc), Recom RCM-265-6MB-BB fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Recom RCM-265-6MB-BB.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.