Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America CP60 265-C1 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America CP60 265-C1 is a 265.0 W STC (239.5 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.29% efficiency, 38.3 V Voc at 25 C, and 43.03 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
239.5 W
Voc @ 25C
38.3 V
Efficiency
16.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America CP60 265-C1 Compare Against Peer CEC Listings?

Engineering position of Centrosolar America CP60 265-C1 (265.0 W STC) vs. GermanSolar USA GSM6-60-265W across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Centrosolar America CP60 265-C1 pairs typical 90.4% PTC-to-STC thermal output (239.5 W real-world rating) with 38.3 V nominal Voc. An 8 kW residential build (8,215 W DC, 7,424 W PTC) saves ~$2,055/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer GermanSolar USA GSM6-60-265W offers a 265.0 W alternative.

Where Does Centrosolar America CP60 265-C1 Fall Across Listed CEC Models?

Plots Centrosolar America CP60 265-C1 at 265.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America CP60 265-C1 (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 265.0 W

What Dataset Percentiles Define Centrosolar America CP60 265-C1?

Benchmarks Centrosolar America CP60 265-C1 on STC wattage, thermal PTC/STC retention, and 16.29 aperture conversion efficiency against CEC peers.

Centrosolar America CP60 265-C1 Engineering BenchmarksPercentile comparison of Centrosolar America CP60 265-C1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention90.4%Module Efficiency16.29%

What Do the Dataset Ranks Show for Centrosolar America CP60 265-C1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America CP60 265-C1 by Centrosolar America.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,670

16.29% Aperture Efficiency

Power density 162.9 W/m2 (3.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.03 V at -10 C (559.4 V string) and 44.38 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,424 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.3 * (1 + (-0.353/100) * (-10 - 25)) = 43.03 V | OCPD = 1.56 * 9.2 = 14.35 A

Inputs from CEC Modules.csv for Centrosolar America CP60 265-C1: Voc=38.3 V, beta_Voc=-0.353%/C, Isc=9.2 A, STC=265.0 W, Area=1.627 m2.

Result: 13 panels max on 600 V (559.4 V); 31 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Centrosolar America CP60 265-C1?

Laboratory test ratings recorded for Centrosolar America CP60 265-C1 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America CP60 265-C1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 239.5 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.89 V / 8.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.353 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.29% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America CP60 265-C1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America CP60 265-C1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 403 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 543 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 665 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Sibling wattage bins and frame colors grouped with Centrosolar America CP60 265-C1 under Centrosolar America to prevent duplicate spec pages.

Sibling CEC listings grouped into the Centrosolar America CP60 265-C1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America CP60 260-C1 260.0 W 235.3 W 38.3 V 30.95 V 15.98%
Centrosolar America CP60 265-C1 265.0 W 239.5 W 38.3 V 30.89 V 16.29%

How Many Centrosolar America CP60 265-C1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Centrosolar America CP60 265-C1 (beta_Voc -0.353%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.3V and beta_Voc=-0.353%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.38 V 13 panels 576.9 V 22 panels
-10 C (14 F) 43.03 V 13 panels 559.4 V 23 panels
0 C (32 F) 41.68 V 14 panels 583.5 V 23 panels
25 C (77 F STC) 38.3 V 15 panels 574.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America CP60 265-C1?

Closest cross-brand CEC competitors to Centrosolar America CP60 265-C1 matched near 265.0 W STC and 38.3 V Voc, led by GermanSolar USA GSM6-60-265W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GermanSolar USA GSM6-60-265W
GermanSolar USA
265.0 W Tie (0 W) 38.3 V 16.29% 90.5%
Boviet Solar Technology Co Ltd BVM6610M-265
Boviet Solar Technology Co Ltd
265.0 W Tie (0 W) 38.2 V 16.29% 91.6%
GCL System Integration Technology Co Ltd GCL-P6/60265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.29% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/60B265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.26% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America CP60 265-C1?

Evaluate Centrosolar America CP60 265-C1 (265.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America CP60 265-C1 reaches 44.38 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America CP60 265-C1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America CP60 265-C1 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GermanSolar USA GSM6-60-265W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 239.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America CP60 265-C1 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America CP60 265-C1?

Multiplying Centrosolar America CP60 265-C1's 9.2 A short-circuit current by 1.56 equals 14.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America CP60 265-C1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.03 V cold Voc at 14 F and handles 9.2 A Isc; string inverters cap Centrosolar America CP60 265-C1 at 13 panels on 600 V.

Is Centrosolar America CP60 265-C1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America CP60 265-C1 rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.