Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SE485M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE485M is a 485.0 W STC (455.4 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 21.09% efficiency, 45.2 V Voc at 25 C, and 49.34 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
485.0 W
PTC Wattage
455.4 W
Voc @ 25C
45.2 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE485M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SE485M handles rooftop heat (455.4 W PTC), 8 kW sizing, and cold winter string voltage.

PEIMAR builds the PEIMAR SE485M (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). Compared against Heliene 132HC-485 M10 SL (485.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Mid-range 45.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.17 A overcurrent floor served by a 25 A breaker.

Where Does PEIMAR SE485M Fall Across Listed CEC Models?

Where PEIMAR SE485M (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE485M (485.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE485M: 485.0 W

What Dataset Percentiles Define PEIMAR SE485M?

Percentile placement of PEIMAR SE485M across power density (210.9 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

PEIMAR SE485M Engineering BenchmarksPercentile comparison of PEIMAR SE485M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage485.0 WPTC/STC Retention93.9%Module Efficiency21.09%

What Do the Dataset Ranks Show for PEIMAR SE485M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SE485M specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #4,730 / 21,677

Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.34 V at -10 C (592.1 V string) and 50.53 V at -20 C (11 max).

8 kW Reference Array

17 Panels = 8,245 W STC

Occupies 39.1 m2 (421 sq ft) producing 7,742 W PTC; NEC 690.8 OCPD floor is 21.17 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.262/100) * (-10 - 25)) = 49.34 V | OCPD = 1.56 * 13.57 = 21.17 A

Inputs from CEC Modules.csv for PEIMAR SE485M: Voc=45.2 V, beta_Voc=-0.262%/C, Isc=13.57 A, STC=485.0 W, Area=2.3 m2.

Result: 12 panels max on 600 V (592.1 V); 17 panels for 8 kW (421 sq ft).

What Are the Published CEC Specifications for PEIMAR SE485M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SE485M. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE485M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 485.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 455.4 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.24 V / 12.69 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (2.3 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE485M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SE485M (485.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.3 kW 322 sq ft $1,577 $2,666
8 kW Class 17 8.24 kW 421 sq ft $2,062 $3,487
10 kW Class 21 10.19 kW 520 sq ft $2,550 $4,313

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SE485M architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SE485M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE475M 475.0 W 445.8 W 45.0 V 38.07 V 20.65%
PEIMAR SE480M 480.0 W 450.6 W 45.1 V 38.15 V 20.87%
PEIMAR SE485M 485.0 W 455.4 W 45.2 V 38.24 V 21.09%
PEIMAR SE490M 490.0 W 460.3 W 45.3 V 38.33 V 21.3%
PEIMAR SE495M 495.0 W 465.1 W 45.4 V 38.41 V 21.52%

How Many PEIMAR SE485M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SE485M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.2V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.53 V 11 panels 555.8 V 19 panels
-10 C (14 F) 49.34 V 12 panels 592.1 V 20 panels
0 C (32 F) 48.16 V 12 panels 577.9 V 20 panels
25 C (77 F STC) 45.2 V 13 panels 587.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE485M?

Alternative CEC solar modules from competing brands near PEIMAR SE485M (485.0 W), including Heliene 132HC-485 M10 SL. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 132HC-485 M10 SL
Heliene
485.0 W Tie (0 W) 45.77 V 21.18% 94.3%
Auxin Solar AXN10M485B
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 92.0%
Auxin Solar AXN10M485W
Auxin Solar
485.0 W Tie (0 W) 43.98 V 22.56% 91.8%
Hanersun Energy Co Ltd HN18N-60HT485W
Hanersun Energy Co Ltd
485.0 W Tie (0 W) 43.0 V 22.99% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE485M?

Evaluate PEIMAR SE485M (485.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE485M reaches 50.53 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 421 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (421 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE485M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE485M 8 kW Residential Fit

Needs 17 modules (421 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Heliene 132HC-485 M10 SL.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 455.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE485M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

What fuse or breaker size does NEC 690.8 require for PEIMAR SE485M?

Multiplying PEIMAR SE485M's 13.57 A short-circuit current by 1.56 equals 21.17 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SE485M before finalizing component orders.

Can PEIMAR SE485M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.34 V cold Voc at 14 F and handles 13.57 A Isc; string inverters cap PEIMAR SE485M at 12 panels on 600 V.

Is PEIMAR SE485M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SE485M rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.