PEIMAR SE520M is a 520.0 W STC (488.0 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.63% efficiency, 49.2 V Voc at 25 C, and 53.71 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 520.0 W
- PTC Wattage
- 488.0 W
- Voc @ 25C
- 49.2 V
- Efficiency
- 20.63%
How Does PEIMAR SE520M Compare Against Peer CEC Listings?
Solar engineering breakdown for PEIMAR SE520M: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Across 5,889 Mono-c-Si listings from PEIMAR and peers, PEIMAR SE520M stands 110.0 W above the 410.0 W Mono-c-Si median and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,562-$2,603/yr in baseline US bill offset. Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does PEIMAR SE520M Fall Across Listed CEC Models?
Distribution marker showing PEIMAR SE520M (520.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define PEIMAR SE520M?
Dataset percentiles tracking PEIMAR SE520M power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for PEIMAR SE520M?
Benchmark highlights for PEIMAR SE520M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 19.9% STC Output
520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.63% Aperture Efficiency
Power density 206.3 W/m2 (0.72 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.71 V at -10 C (590.8 V string) and 55.0 V at -20 C (10 max).
16 Panels = 8,320 W STC
Occupies 40.3 m2 (434 sq ft) producing 7,808 W PTC; NEC 690.8 OCPD floor is 20.86 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.2 * (1 + (-0.262/100) * (-10 - 25)) = 53.71 V | OCPD = 1.56 * 13.37 = 20.86 A
Inputs from CEC Modules.csv for PEIMAR SE520M: Voc=49.2 V, beta_Voc=-0.262%/C, Isc=13.37 A, STC=520.0 W, Area=2.52 m2.
Result: 11 panels max on 600 V (590.8 V); 16 panels for 8 kW (434 sq ft).
What Are the Published CEC Specifications for PEIMAR SE520M?
Official CEC datasheet figures for PEIMAR SE520M (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 488.0 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.63 V / 12.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.63% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SE520M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PEIMAR SE520M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.24 kW | 326 sq ft | $1,562 | $2,641 |
| 8 kW Class | 16 | 8.32 kW | 434 sq ft | $2,082 | $3,521 |
| 10 kW Class | 20 | 10.4 kW | 543 sq ft | $2,603 | $4,402 |
How Many PEIMAR SE520M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SE520M (53.71 V at 14 F). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.0 V | 10 panels | 550.0 V | 18 panels |
| -10 C (14 F) | 53.71 V | 11 panels | 590.8 V | 18 panels |
| 0 C (32 F) | 52.42 V | 11 panels | 576.6 V | 19 panels |
| 25 C (77 F STC) | 49.2 V | 12 panels | 590.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE520M?
Competing CEC solar panels closest to PEIMAR SE520M in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM7612M-520-H-HC.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7612M-520-H-HC Boviet Solar Technology Co Ltd |
520.0 W | Tie (0 W) | 49.39 V | 20.04% | 93.8% |
| AXITEC AC-520MH/144VB AXITEC |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| ELITE Solar ET-M772BH520BB ELITE Solar |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| Chint New Energy Technology Co Ltd CHSM72M-HC-520 Chint New Energy Technology Co Ltd |
520.0 W | Tie (0 W) | 48.9 V | 20.97% | 92.5% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SE520M?
Evaluate PEIMAR SE520M (520.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE520M reaches 55.0 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (434 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PEIMAR SE520M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SE520M 8 kW Residential Fit
Needs 16 modules (434 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-520-H-HC.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 488.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SE520M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What fuse or breaker size does NEC 690.8 require for PEIMAR SE520M?
Multiplying PEIMAR SE520M's 13.37 A short-circuit current by 1.56 equals 20.86 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SE520M before finalizing component orders.
Can PEIMAR SE520M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.71 V cold Voc at 14 F and handles 13.37 A Isc; string inverters cap PEIMAR SE520M at 11 panels on 600 V.
Is PEIMAR SE520M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SE520M rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)