Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE505M is a 505.0 W STC (474.7 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 21.96% efficiency, 45.6 V Voc at 25 C, and 49.78 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
505.0 W
PTC Wattage
474.7 W
Voc @ 25C
45.6 V
Efficiency
21.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE505M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SE505M (Mono-c-Si) residential solar systems. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Homeowners evaluating PEIMAR SE505M need 12 panels for 6 kW or 16 panels (396 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (396 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.262%/C) pushes open-circuit voltage to 49.78 V at 14 F and 50.98 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SE505M Fall Across Listed CEC Models?

Comparison of PEIMAR SE505M (505.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE505M (505.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE505M: 505.0 W

What Dataset Percentiles Define PEIMAR SE505M?

Relative ranking of PEIMAR SE505M across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

PEIMAR SE505M Engineering BenchmarksPercentile comparison of PEIMAR SE505M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage505.0 WPTC/STC Retention94.0%Module Efficiency21.96%

What Do the Dataset Ranks Show for PEIMAR SE505M?

Summary of PEIMAR SE505M output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,444 / 21,677

Top 20.8% STC Output

505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,188

21.96% Aperture Efficiency

Power density 219.6 W/m2 (2.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.78 V at -10 C (597.4 V string) and 50.98 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,080 W STC

Occupies 36.8 m2 (396 sq ft) producing 7,595 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.6 * (1 + (-0.262/100) * (-10 - 25)) = 49.78 V | OCPD = 1.56 * 13.99 = 21.82 A

Inputs from CEC Modules.csv for PEIMAR SE505M: Voc=45.6 V, beta_Voc=-0.262%/C, Isc=13.99 A, STC=505.0 W, Area=2.3 m2.

Result: 12 panels max on 600 V (597.4 V); 16 panels for 8 kW (396 sq ft).

What Are the Published CEC Specifications for PEIMAR SE505M?

Complete CEC test sheet for PEIMAR SE505M including Isc (13.99 A), Voc (45.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE505M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 505.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 474.7 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.63 V / 13.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.96% (2.3 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE505M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SE505M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.06 kW 297 sq ft $1,517 $2,565
8 kW Class 16 8.08 kW 396 sq ft $2,022 $3,420
10 kW Class 20 10.1 kW 495 sq ft $2,528 $4,275

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SE505M series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the PEIMAR SE505M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE500M 500.0 W 469.9 W 45.5 V 38.5 V 21.74%
PEIMAR SE505M 505.0 W 474.7 W 45.6 V 38.63 V 21.96%

How Many PEIMAR SE505M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SE505M (45.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.6V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.98 V 11 panels 560.8 V 19 panels
-10 C (14 F) 49.78 V 12 panels 597.4 V 20 panels
0 C (32 F) 48.59 V 12 panels 583.1 V 20 panels
25 C (77 F STC) 45.6 V 13 panels 592.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE505M?

Four comparable CEC modules such as Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 (505.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505
Jiangsu Runergy New Energy Technology Co Ltd
505.0 W Tie (0 W) 45.72 V 29.88% 94.1%
Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-505
Jiangsu Runergy New Energy Technology Co Ltd
505.0 W Tie (0 W) 45.72 V 29.88% 94.0%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW505M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
505.0 W Tie (0 W) 45.16 V 26.58% 95.0%
Elin Energy (Sirius PV) ELNSM66M-HC-510
Elin Energy (Sirius PV)
510.0 W +5.0 W 46.05 V 21.61% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE505M?

Evaluate PEIMAR SE505M (505.0 W STC, 45.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE505M reaches 50.98 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 396 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (396 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE505M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE505M 8 kW Residential Fit

Needs 16 modules (396 sq ft) with a 25 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 474.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE505M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Why is PEIMAR SE505M PTC wattage (474.7 W) lower than STC (505.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 474.7 W PTC (94.0% retention) across PEIMAR SE505M's 2.3 m2 aperture.

Who should skip PEIMAR SE505M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 PEIMAR SE505M panels (396 sq ft) leave unusable roof gaps vs. Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.

What is the 1,000 V commercial string limit for PEIMAR SE505M?

On 1,000 V commercial inverters at -10 C (49.78 V cold Voc), PEIMAR SE505M fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SE505M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes