Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR DR10H550M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR DR10H550M is a 550.0 W STC (515.7 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.6 V Voc at 25 C, and 54.91 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
515.7 W
Voc @ 25C
49.6 V
Efficiency
21.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR DR10H550M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR DR10H550M handles rooftop heat (515.7 W PTC), 8 kW sizing, and cold winter string voltage.

PEIMAR builds the PEIMAR DR10H550M (Mono-c-Si) as a large-format commercial and ground-mount module delivering 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). Compared against Energate Energy Inc EG-144L550W (550.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.89 A overcurrent floor served by a 25 A breaker.

Where Does PEIMAR DR10H550M Fall Across Listed CEC Models?

Where PEIMAR DR10H550M (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR DR10H550M (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR DR10H550M: 550.0 W

What Dataset Percentiles Define PEIMAR DR10H550M?

Percentile placement of PEIMAR DR10H550M across power density (214.8 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

PEIMAR DR10H550M Engineering BenchmarksPercentile comparison of PEIMAR DR10H550M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention93.8%Module Efficiency21.48%

What Do the Dataset Ranks Show for PEIMAR DR10H550M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR DR10H550M specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,517

21.48% Aperture Efficiency

Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.91 V at -10 C (549.1 V string) and 56.43 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 21.89 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.306/100) * (-10 - 25)) = 54.91 V | OCPD = 1.56 * 14.03 = 21.89 A

Inputs from CEC Modules.csv for PEIMAR DR10H550M: Voc=49.6 V, beta_Voc=-0.306%/C, Isc=14.03 A, STC=550.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (549.1 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for PEIMAR DR10H550M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR DR10H550M. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR DR10H550M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 515.7 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.9 V / 13.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.48% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR DR10H550M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR DR10H550M (550.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 303 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 413 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 524 sq ft $2,616 $4,423

How Many PEIMAR DR10H550M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR DR10H550M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.6V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.43 V 10 panels 564.3 V 17 panels
-10 C (14 F) 54.91 V 10 panels 549.1 V 18 panels
0 C (32 F) 53.39 V 11 panels 587.3 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H550M?

Alternative CEC solar modules from competing brands near PEIMAR DR10H550M (550.0 W), including Energate Energy Inc EG-144L550W. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Energate Energy Inc EG-144L550W
Energate Energy Inc
550.0 W Tie (0 W) 49.62 V 21.48% 93.8%
Energate Enerji retim San A EG-144L550W
Energate Enerji retim San A
550.0 W Tie (0 W) 49.62 V 21.48% 93.8%
Dehui Solar Power (Vietnam) CoLtd DH-M172B 550W
Dehui Solar Power (Vietnam) CoLtd
550.0 W Tie (0 W) 49.77 V 21.48% 93.5%
Dehui Solar Power (Vietnam) CoLtd DH-M172W 550W
Dehui Solar Power (Vietnam) CoLtd
550.0 W Tie (0 W) 49.77 V 21.48% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H550M?

Evaluate PEIMAR DR10H550M (550.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H550M reaches 56.43 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of PEIMAR DR10H550M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR DR10H550M 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Energate Energy Inc EG-144L550W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 515.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR DR10H550M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

What fuse or breaker size does NEC 690.8 require for PEIMAR DR10H550M?

Multiplying PEIMAR DR10H550M's 14.03 A short-circuit current by 1.56 equals 21.89 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR DR10H550M before finalizing component orders.

Can PEIMAR DR10H550M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.91 V cold Voc at 14 F and handles 14.03 A Isc; string inverters cap PEIMAR DR10H550M at 10 panels on 600 V.

Is PEIMAR DR10H550M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR DR10H550M rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.