PEIMAR DR10H550M is a 550.0 W STC (515.7 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.6 V Voc at 25 C, and 54.91 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 515.7 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 21.48%
How Does PEIMAR DR10H550M Compare Against Peer CEC Listings?
How PEIMAR PEIMAR DR10H550M handles rooftop heat (515.7 W PTC), 8 kW sizing, and cold winter string voltage.
PEIMAR builds the PEIMAR DR10H550M (Mono-c-Si) as a large-format commercial and ground-mount module delivering 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). Compared against Energate Energy Inc EG-144L550W (550.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.89 A overcurrent floor served by a 25 A breaker.
Where Does PEIMAR DR10H550M Fall Across Listed CEC Models?
Where PEIMAR DR10H550M (550.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR DR10H550M?
Percentile placement of PEIMAR DR10H550M across power density (214.8 W/m2), thermal retention, and nameplate STC wattage. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for PEIMAR DR10H550M?
Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR DR10H550M specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.48% Aperture Efficiency
Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.91 V at -10 C (549.1 V string) and 56.43 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 21.89 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.306/100) * (-10 - 25)) = 54.91 V | OCPD = 1.56 * 14.03 = 21.89 A
Inputs from CEC Modules.csv for PEIMAR DR10H550M: Voc=49.6 V, beta_Voc=-0.306%/C, Isc=14.03 A, STC=550.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (549.1 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for PEIMAR DR10H550M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR DR10H550M. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 515.7 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.9 V / 13.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.306 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.48% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR DR10H550M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR DR10H550M (550.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |
How Many PEIMAR DR10H550M Modules Fit in a Cold-Weather String?
Maximum series module counts for PEIMAR DR10H550M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.43 V | 10 panels | 564.3 V | 17 panels |
| -10 C (14 F) | 54.91 V | 10 panels | 549.1 V | 18 panels |
| 0 C (32 F) | 53.39 V | 11 panels | 587.3 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H550M?
Alternative CEC solar modules from competing brands near PEIMAR DR10H550M (550.0 W), including Energate Energy Inc EG-144L550W. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Energate Energy Inc EG-144L550W Energate Energy Inc |
550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
| Energate Enerji retim San A EG-144L550W Energate Enerji retim San A |
550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
| Dehui Solar Power (Vietnam) CoLtd DH-M172B 550W Dehui Solar Power (Vietnam) CoLtd |
550.0 W | Tie (0 W) | 49.77 V | 21.48% | 93.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M172W 550W Dehui Solar Power (Vietnam) CoLtd |
550.0 W | Tie (0 W) | 49.77 V | 21.48% | 93.9% |
What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H550M?
Evaluate PEIMAR DR10H550M (550.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H550M reaches 56.43 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of PEIMAR DR10H550M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR DR10H550M 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Energate Energy Inc EG-144L550W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 515.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR DR10H550M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What fuse or breaker size does NEC 690.8 require for PEIMAR DR10H550M?
Multiplying PEIMAR DR10H550M's 14.03 A short-circuit current by 1.56 equals 21.89 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR DR10H550M before finalizing component orders.
Can PEIMAR DR10H550M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.91 V cold Voc at 14 F and handles 14.03 A Isc; string inverters cap PEIMAR DR10H550M at 10 panels on 600 V.
Is PEIMAR DR10H550M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR DR10H550M rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)