Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SE535M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE535M is a 535.0 W STC (502.5 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 21.23% efficiency, 49.5 V Voc at 25 C, and 54.04 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
502.5 W
Voc @ 25C
49.5 V
Efficiency
21.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE535M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SE535M handles rooftop heat (502.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SE535M exhibits 13.67 A short-circuit current, requiring a 21.33 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.8 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does PEIMAR SE535M Fall Across Listed CEC Models?

Where PEIMAR SE535M (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE535M (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE535M: 535.0 W

What Dataset Percentiles Define PEIMAR SE535M?

Percentile placement of PEIMAR SE535M across power density (212.3 W/m2), thermal retention, and nameplate STC wattage. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

PEIMAR SE535M Engineering BenchmarksPercentile comparison of PEIMAR SE535M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention93.9%Module Efficiency21.23%

What Do the Dataset Ranks Show for PEIMAR SE535M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SE535M specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,486

21.23% Aperture Efficiency

Power density 212.3 W/m2 (1.32 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.04 V at -10 C (594.4 V string) and 55.34 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,538 W PTC; NEC 690.8 OCPD floor is 21.33 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.5 * (1 + (-0.262/100) * (-10 - 25)) = 54.04 V | OCPD = 1.56 * 13.67 = 21.33 A

Inputs from CEC Modules.csv for PEIMAR SE535M: Voc=49.5 V, beta_Voc=-0.262%/C, Isc=13.67 A, STC=535.0 W, Area=2.52 m2.

Result: 11 panels max on 600 V (594.4 V); 15 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for PEIMAR SE535M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SE535M. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE535M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 502.5 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.88 V / 12.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.23% (2.52 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE535M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SE535M (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 326 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 407 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 515 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SE535M architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the PEIMAR SE535M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE525M 525.0 W 492.8 W 49.3 V 41.8 V 20.83%
PEIMAR SE530M 530.0 W 497.7 W 49.4 V 41.79 V 21.03%
PEIMAR SE535M 535.0 W 502.5 W 49.5 V 41.88 V 21.23%
PEIMAR SE540M 540.0 W 507.3 W 49.6 V 41.96 V 21.43%
PEIMAR SE545M 545.0 W 512.1 W 49.7 V 42.05 V 21.63%

How Many PEIMAR SE535M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SE535M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.5V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.34 V 10 panels 553.4 V 18 panels
-10 C (14 F) 54.04 V 11 panels 594.4 V 18 panels
0 C (32 F) 52.74 V 11 panels 580.1 V 18 panels
25 C (77 F STC) 49.5 V 12 panels 594.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE535M?

Alternative CEC solar modules from competing brands near PEIMAR SE535M (535.0 W), including Chint New Energy Technology Co Ltd CHSM72M-HC-535.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chint New Energy Technology Co Ltd CHSM72M-HC-535
Chint New Energy Technology Co Ltd
535.0 W Tie (0 W) 49.5 V 21.57% 92.6%
Heliene 144HC-535 M10 SL
Heliene
535.0 W Tie (0 W) 49.47 V 21.49% 93.5%
ELITE Solar ET-M772BH535GL
ELITE Solar
535.0 W Tie (0 W) 49.45 V 20.9% 94.1%
Hyperion Solar HY-WH144P8-535
Hyperion Solar
535.0 W Tie (0 W) 49.45 V 20.74% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE535M?

Evaluate PEIMAR SE535M (535.0 W STC, 49.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE535M reaches 55.34 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE535M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE535M 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72M-HC-535.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 502.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE535M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Why is PEIMAR SE535M PTC wattage (502.5 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 502.5 W PTC (93.9% retention) across PEIMAR SE535M's 2.52 m2 aperture.

Who should skip PEIMAR SE535M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 PEIMAR SE535M panels (407 sq ft) leave unusable roof gaps vs. Chint New Energy Technology Co Ltd CHSM72M-HC-535.

What is the 1,000 V commercial string limit for PEIMAR SE535M?

On 1,000 V commercial inverters at -10 C (54.04 V cold Voc), PEIMAR SE535M fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SE535M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.