Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR DR10H540M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR DR10H540M is a 540.0 W STC (506.1 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.4 V Voc at 25 C, and 54.69 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
506.1 W
Voc @ 25C
49.4 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR DR10H540M Compare Against Peer CEC Listings?

Engineering position of PEIMAR DR10H540M (540.0 W STC) vs. Energate Energy Inc EG-144L540W across 5,889 CEC Mono-c-Si solar modules.

Ranking #3,265 across 21,677 CEC solar panels (top 16.3%; higher than 83.7% of peers), PEIMAR DR10H540M operates as a large-format commercial and ground-mount module sitting 130.0 W above the 410.0 W Mono-c-Si median. Higher 49.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 15 panels occupy 413 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR DR10H540M Fall Across Listed CEC Models?

Plots PEIMAR DR10H540M at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR DR10H540M (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR DR10H540M: 540.0 W

What Dataset Percentiles Define PEIMAR DR10H540M?

Benchmarks PEIMAR DR10H540M on STC wattage, thermal PTC/STC retention, and 21.09 aperture conversion efficiency against CEC peers.

PEIMAR DR10H540M Engineering BenchmarksPercentile comparison of PEIMAR DR10H540M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.7%Module Efficiency21.09%

What Do the Dataset Ranks Show for PEIMAR DR10H540M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR DR10H540M by PEIMAR.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.69 V at -10 C (546.9 V string) and 56.2 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,592 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.306/100) * (-10 - 25)) = 54.69 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for PEIMAR DR10H540M: Voc=49.4 V, beta_Voc=-0.306%/C, Isc=13.85 A, STC=540.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (546.9 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for PEIMAR DR10H540M?

Laboratory test ratings recorded for PEIMAR DR10H540M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR DR10H540M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 506.1 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.7 V / 13.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR DR10H540M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR DR10H540M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 331 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 413 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 524 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR DR10H540M under PEIMAR to prevent duplicate spec pages. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the PEIMAR DR10H540M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR DR10H530M 530.0 W 496.5 W 49.3 V 40.6 V 20.7%
PEIMAR DR10H535M 535.0 W 501.3 W 49.3 V 40.6 V 20.9%
PEIMAR DR10H540M 540.0 W 506.1 W 49.4 V 40.7 V 21.09%
PEIMAR DR10H545M 545.0 W 510.9 W 49.5 V 40.8 V 21.29%

How Many PEIMAR DR10H540M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR DR10H540M (beta_Voc -0.306%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.4V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.2 V 10 panels 562.0 V 17 panels
-10 C (14 F) 54.69 V 10 panels 546.9 V 18 panels
0 C (32 F) 53.18 V 11 panels 585.0 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H540M?

Closest cross-brand CEC competitors to PEIMAR DR10H540M matched near 540.0 W STC and 49.4 V Voc, led by Energate Energy Inc EG-144L540W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Energate Energy Inc EG-144L540W
Energate Energy Inc
540.0 W Tie (0 W) 49.42 V 21.09% 93.7%
Energate Enerji retim San A EG-144L540W
Energate Enerji retim San A
540.0 W Tie (0 W) 49.42 V 21.09% 93.7%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
540.0 W Tie (0 W) 49.5 V 21.09% 93.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
540.0 W Tie (0 W) 49.5 V 21.09% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H540M?

Evaluate PEIMAR DR10H540M (540.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H540M reaches 56.2 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of PEIMAR DR10H540M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR DR10H540M 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Energate Energy Inc EG-144L540W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 506.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR DR10H540M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many PEIMAR DR10H540M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR DR10H540M cold Voc rises from 49.4 V to 54.69 V (beta_Voc -0.306%/C), capping a 600 V string at 10 panels (546.9 V).

How much roof area does an 8 kW array of PEIMAR DR10H540M need?

An 8 kW DC system uses 15 PEIMAR DR10H540M modules (8,100 W STC / 7,592 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does PEIMAR DR10H540M compare against Energate Energy Inc EG-144L540W?

PEIMAR DR10H540M outputs 540.0 W STC (49.4 V Voc, rank #3,265 of 21,677), while Energate Energy Inc EG-144L540W delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.