PEIMAR SG290M is a 290.0 W STC (260.5 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.95% efficiency, 44.16 V Voc at 25 C, and 49.4 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
260.5 W
Voc @ 25C
44.16 V
Efficiency
14.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG290M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SG290M handles rooftop heat (260.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SG290M exhibits 8.64 A short-circuit current, requiring a 13.48 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (120.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 54.3 m2 for an 8 kW system (35 panels for 10 kW). Mid-range 44.16 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does PEIMAR SG290M Fall Across Listed CEC Models?

Where PEIMAR SG290M (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG290M (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG290M: 290.0 W

What Dataset Percentiles Define PEIMAR SG290M?

Percentile placement of PEIMAR SG290M across power density (149.5 W/m2), thermal retention, and nameplate STC wattage. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

PEIMAR SG290M Engineering BenchmarksPercentile comparison of PEIMAR SG290M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention89.8%Module Efficiency14.95%

What Do the Dataset Ranks Show for PEIMAR SG290M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG290M specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,805

14.95% Aperture Efficiency

Power density 149.5 W/m2 (4.96 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.4 V at -10 C (592.8 V string) and 50.9 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.3 m2 (585 sq ft) producing 7,294 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.16 * (1 + (-0.339/100) * (-10 - 25)) = 49.4 V | OCPD = 1.56 * 8.64 = 13.48 A

Inputs from CEC Modules.csv for PEIMAR SG290M: Voc=44.16 V, beta_Voc=-0.339%/C, Isc=8.64 A, STC=290.0 W, Area=1.94 m2.

Result: 12 panels max on 600 V (592.8 V); 28 panels for 8 kW (585 sq ft).

What Are the Published CEC Specifications for PEIMAR SG290M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG290M. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG290M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 260.5 W (89.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.16 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.9 V / 8.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.95% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG290M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG290M (290.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 439 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 585 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 731 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SG290M architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the PEIMAR SG290M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG280M 280.0 W 251.2 W 43.91 V 35.7 V 14.43%
PEIMAR SG285M 285.0 W 255.8 W 44.03 V 35.8 V 14.69%
PEIMAR SG290M 290.0 W 260.5 W 44.16 V 35.9 V 14.95%
PEIMAR SG295M 295.0 W 265.1 W 44.28 V 36.0 V 15.2%

How Many PEIMAR SG290M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SG290M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.16V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.9 V 11 panels 559.9 V 19 panels
-10 C (14 F) 49.4 V 12 panels 592.8 V 20 panels
0 C (32 F) 47.9 V 12 panels 574.8 V 20 panels
25 C (77 F STC) 44.16 V 13 panels 574.1 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG290M?

Alternative CEC solar modules from competing brands near PEIMAR SG290M (290.0 W), including Centrosolar America DM72 290. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG290M?

Evaluate PEIMAR SG290M (290.0 W STC, 44.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG290M reaches 50.9 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG290M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG290M 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 260.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG290M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Why is PEIMAR SG290M PTC wattage (260.5 W) lower than STC (290.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 260.5 W PTC (89.8% retention) across PEIMAR SG290M's 1.94 m2 aperture.

Who should skip PEIMAR SG290M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 PEIMAR SG290M panels (585 sq ft) leave unusable roof gaps vs. Centrosolar America DM72 290.

What is the 1,000 V commercial string limit for PEIMAR SG290M?

On 1,000 V commercial inverters at -10 C (49.4 V cold Voc), PEIMAR SG290M fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SG290M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.