Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG215P — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG215P is a 215.0 W STC (191.5 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.22% efficiency, 35.4 V Voc at 25 C, and 39.87 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
215.0 W
PTC Wattage
191.5 W
Voc @ 25C
35.4 V
Efficiency
13.22%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG215P Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SG215P handles rooftop heat (191.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SG215P exhibits 8.16 A short-circuit current, requiring a 12.73 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,859 of 21,677 (63.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 61.8 m2 for an 8 kW system (47 panels for 10 kW). Lower 35.4 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

Where Does PEIMAR SG215P Fall Across Listed CEC Models?

Where PEIMAR SG215P (215.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG215P (215.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG215P: 215.0 W

What Dataset Percentiles Define PEIMAR SG215P?

Percentile placement of PEIMAR SG215P across power density (132.1 W/m2), thermal retention, and nameplate STC wattage. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

PEIMAR SG215P Engineering BenchmarksPercentile comparison of PEIMAR SG215P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage215.0 WPTC/STC Retention89.1%Module Efficiency13.22%

What Do the Dataset Ranks Show for PEIMAR SG215P?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG215P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,859 / 21,677

215.0 W STC · Higher Than 3.5%

215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,345

13.22% Aperture Efficiency

Power density 132.1 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.87 V at -10 C (598.0 V string) and 41.15 V at -20 C (14 max).

8 kW Reference Array

38 Panels = 8,170 W STC

Occupies 61.8 m2 (665 sq ft) producing 7,277 W PTC; NEC 690.8 OCPD floor is 12.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.4 * (1 + (-0.361/100) * (-10 - 25)) = 39.87 V | OCPD = 1.56 * 8.16 = 12.73 A

Inputs from CEC Modules.csv for PEIMAR SG215P: Voc=35.4 V, beta_Voc=-0.361%/C, Isc=8.16 A, STC=215.0 W, Area=1.627 m2.

Result: 15 panels max on 600 V (598.0 V); 38 panels for 8 kW (665 sq ft).

What Are the Published CEC Specifications for PEIMAR SG215P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG215P. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG215P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 215.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 191.5 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.16 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.5 V / 7.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.361 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.22% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many PEIMAR SG215P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG215P (215.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.02 kW 490 sq ft $1,507 $2,548
8 kW Class 38 8.17 kW 665 sq ft $2,045 $3,458
10 kW Class 47 10.11 kW 823 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SG215P architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the PEIMAR SG215P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG205P 205.0 W 182.3 W 35.1 V 29.3 V 12.6%
PEIMAR SG210P 210.0 W 186.9 W 35.2 V 29.4 V 12.91%
PEIMAR SG215P 215.0 W 191.5 W 35.4 V 29.5 V 13.22%
PEIMAR SG220P 220.0 W 196.0 W 35.4 V 29.5 V 13.52%

How Many PEIMAR SG215P Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SG215P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=35.4V and beta_Voc=-0.361%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.15 V 14 panels 576.1 V 24 panels
-10 C (14 F) 39.87 V 15 panels 598.0 V 25 panels
0 C (32 F) 38.59 V 15 panels 578.9 V 25 panels
25 C (77 F STC) 35.4 V 16 panels 566.4 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG215P?

Alternative CEC solar modules from competing brands near PEIMAR SG215P (215.0 W), including Anhui Rinengzhongtian Semiconductor Development QJP215-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP215-60
Anhui Rinengzhongtian Semiconductor Development
215.0 W Tie (0 W) 35.4 V 13.22% 89.1%
Advance Power API-P215
Advance Power
215.0 W Tie (0 W) 36.0 V 13.13% 89.0%
Auxin Solar AXN6P610T215
Auxin Solar
215.0 W Tie (0 W) 36.0 V 13.13% 89.0%
Anji Dasol Solar Energy Science & Technology DS-A4-215
Anji Dasol Solar Energy Science & Technology
215.0 W Tie (0 W) 36.3 V 13.06% 87.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG215P?

Evaluate PEIMAR SG215P (215.0 W STC, 35.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG215P reaches 41.15 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 38 panels for an 8 kW build require 665 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (665 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG215P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG215P 8 kW Residential Fit

Needs 38 modules (665 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP215-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 191.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG215P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Why is PEIMAR SG215P PTC wattage (191.5 W) lower than STC (215.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 191.5 W PTC (89.1% retention) across PEIMAR SG215P's 1.627 m2 aperture.

Who should skip PEIMAR SG215P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 38 PEIMAR SG215P panels (665 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP215-60.

What is the 1,000 V commercial string limit for PEIMAR SG215P?

On 1,000 V commercial inverters at -10 C (39.87 V cold Voc), PEIMAR SG215P fits up to 25 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SG215P.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.